📄 qep_data_bus.sum
字号:
*******************************************************
Cell: qep_data_bus View: INTERFACE Library: work
*******************************************************
Total accumulated area :
Number of CARRYs : 210
Number of CASCADEs : 208
Number of DFFs : 324
Number of LCs : 843
Number of TRIs : 8
Number of VCC : 9
Number of accumulated instances : 1333
Number of ports : 69
Number of nets : 602
Number of instances : 390
Number of references to this view : 0
Cell Library References Total Area
CASCADE2 flex10a 72 x 1 72 CASCADEs
1 72 LCs
DFF flex10a 36 x 1 36 DFFs
1 36 LCs
DFFE flex10a 48 x 1 48 DFFs
1 48 LCs
F1_LUT flex10a 10 x
F2_CAS flex10a 48 x 1 48 CASCADEs
1 48 LCs
F2_LUT flex10a 37 x 1 37 LCs
F3_LUT flex10a 68 x 1 68 LCs
F4_CAS flex10a 24 x 1 24 CASCADEs
1 24 LCs
F4_LUT flex10a 24 x 1 24 LCs
TRI flex10a 8 x 1 8 TRIs
VCC flex10a 1 x 1 1 VCC
data_bus_notri work 1 x 1 1 VCC
37 37 CASCADEs
99 99 LCs
35 35 DFFs
disp work 1 x 1 1 VCC
27 27 CASCADEs
19 19 DFFs
93 93 LCs
24 24 CARRYs
lpm_counter_16_421_0 OPERATORS 6 x 16 96 CARRYs
16 96 LCs
qep4_notri work 6 x 8 48 CASCADEs
1 6 VCC
31 186 DFFs
15 90 CARRYs
59 354 LCs
*******************************************************
Cell: disp View: INTERFACE_unfold_1818 Library: work
*******************************************************
Total accumulated area :
Number of CARRYs : 24
Number of CASCADEs : 27
Number of DFFs : 19
Number of LCs : 93
Number of VCC : 1
Number of accumulated instances : 106
Number of ports : 25
Number of nets : 120
Number of instances : 106
Number of references to this view : 1
Cell Library References Total Area
CASCADE2 flex10a 14 x 1 14 CASCADEs
1 14 LCs
DFF flex10a 19 x 1 19 DFFs
1 19 LCs
F1_LUT flex10a 3 x
F2_CAS flex10a 4 x 1 4 CASCADEs
1 4 LCs
F2_LUT flex10a 13 x 1 13 LCs
F3_LUT flex10a 9 x 1 9 LCs
F4_CAS flex10a 9 x 1 9 CASCADEs
1 9 LCs
F4_LUT flex10a 33 x 1 33 LCs
VCC flex10a 1 x 1 1 VCC
lpm_counter_24_292_0 OPERATORS 1 x 24 24 CARRYs
24 24 LCs
*******************************************************
Cell: lpm_counter_24_292_0 View: LPM Library: OPERATORS
*******************************************************
Total accumulated area :
Number of CARRYs : 24
Number of LCs : 24
Number of ports : 26
Number of nets : 0
Number of instances : 0
Number of references to this view : 3
*******************************************************
Cell: data_bus_notri View: INTERFACE_unfold_2093 Library: work
*******************************************************
Total accumulated area :
Number of CASCADEs : 37
Number of DFFs : 35
Number of LCs : 99
Number of VCC : 1
Number of accumulated instances : 155
Number of ports : 60
Number of nets : 182
Number of instances : 155
Number of references to this view : 1
Cell Library References Total Area
CASCADE2 flex10a 20 x 1 20 CASCADEs
1 20 LCs
DFF flex10a 27 x 1 27 DFFs
1 27 LCs
DFFE flex10a 8 x 1 8 DFFs
1 8 LCs
F1_LUT flex10a 7 x
F2_CAS flex10a 2 x 1 2 CASCADEs
1 2 LCs
F2_LUT flex10a 21 x 1 21 LCs
F3_CAS flex10a 8 x 1 8 CASCADEs
1 8 LCs
F3_LUT flex10a 29 x 1 29 LCs
F4_CAS flex10a 8 x 1 8 CASCADEs
1 8 LCs
F4_LUT flex10a 24 x 1 24 LCs
VCC flex10a 1 x 1 1 VCC
*******************************************************
Cell: qep4_notri View: INTERFACE Library: work
*******************************************************
Total accumulated area :
Number of CARRYs : 15
Number of CASCADEs : 8
Number of DFFs : 31
Number of LCs : 59
Number of VCC : 1
Number of accumulated instances : 115
Number of ports : 14
Number of nets : 121
Number of instances : 115
Number of references to this view : 6
Cell Library References Total Area
CARRY3 flex10a 15 x 1 15 CARRYs
CASCADE2 flex10a 8 x 1 8 CASCADEs
1 8 LCs
DFF flex10a 7 x 1 7 DFFs
1 7 LCs
DFFE flex10a 24 x 1 24 DFFs
1 24 LCs
F1_LUT flex10a 1 x
F2_CAS flex10a 8 x 1 8 CASCADEs
1 8 LCs
F2_LUT flex10a 25 x 1 25 LCs
F3_LUT flex10a 25 x 1 25 LCs
F4_LUT flex10a 1 x 1 1 LCs
VCC flex10a 1 x 1 1 VCC
⌨️ 快捷键说明
复制代码
Ctrl + C
搜索代码
Ctrl + F
全屏模式
F11
切换主题
Ctrl + Shift + D
显示快捷键
?
增大字号
Ctrl + =
减小字号
Ctrl + -