⭐ 欢迎来到虫虫下载站! | 📦 资源下载 📁 资源专辑 ℹ️ 关于我们
⭐ 虫虫下载站

📄 digital6counter.map.rpt

📁 数字时钟vhdl实现
💻 RPT
📖 第 1 页 / 共 3 页
字号:
; Total fan-out        ; 795                  ;
; Average fan-out      ; 5.56                 ;
+----------------------+----------------------+


+-----------------------------------------------------------------------------------+
; Analysis & Synthesis Resource Utilization by Entity                               ;
+----------------------------+------------+------+----------------------------------+
; Compilation Hierarchy Node ; Macrocells ; Pins ; Full Hierarchy Name              ;
+----------------------------+------------+------+----------------------------------+
; |DigitalClock              ; 119        ; 24   ; |DigitalClock                    ;
;    |choice1from6:inst8|    ; 22         ; 0    ; |DigitalClock|choice1from6:inst8 ;
;    |counter:inst11|        ; 8          ; 0    ; |DigitalClock|counter:inst11     ;
;    |counter:inst1|         ; 9          ; 0    ; |DigitalClock|counter:inst1      ;
;    |counter:inst2|         ; 9          ; 0    ; |DigitalClock|counter:inst2      ;
;    |counter:inst3|         ; 8          ; 0    ; |DigitalClock|counter:inst3      ;
;    |counter:inst4|         ; 9          ; 0    ; |DigitalClock|counter:inst4      ;
;    |counter:inst5|         ; 8          ; 0    ; |DigitalClock|counter:inst5      ;
;    |counter:inst6|         ; 4          ; 0    ; |DigitalClock|counter:inst6      ;
;    |counter:inst7|         ; 9          ; 0    ; |DigitalClock|counter:inst7      ;
;    |counter:inst|          ; 17         ; 0    ; |DigitalClock|counter:inst       ;
;    |leddrv:inst10|         ; 8          ; 0    ; |DigitalClock|leddrv:inst10      ;
;    |seg7_leddrv:inst9|     ; 8          ; 0    ; |DigitalClock|seg7_leddrv:inst9  ;
+----------------------------+------------+------+----------------------------------+


+------------------------------------------------------------+
; Parameter Settings for User Entity Instance: counter:inst1 ;
+---------------------+-------+------------------------------+
; Parameter Name      ; Value ; Type                         ;
+---------------------+-------+------------------------------+
; divisor             ; 10    ; Untyped                      ;
; inner_counter_width ; 4     ; Untyped                      ;
; unit                ; 1001  ; Untyped                      ;
+---------------------+-------+------------------------------+
Note: In order to hide this table in the UI and the text report file, please set the "Show Parameter Settings Tables in Synthesis Report" option in "Analysis and Synthesis Settings -> More Settings" to "Off".


+-------------------------------------------------------------+
; Parameter Settings for User Entity Instance: counter:inst11 ;
+---------------------+-------+-------------------------------+
; Parameter Name      ; Value ; Type                          ;
+---------------------+-------+-------------------------------+
; divisor             ; 100   ; Untyped                       ;
; inner_counter_width ; 8     ; Untyped                       ;
; unit                ; 1001  ; Untyped                       ;
+---------------------+-------+-------------------------------+
Note: In order to hide this table in the UI and the text report file, please set the "Show Parameter Settings Tables in Synthesis Report" option in "Analysis and Synthesis Settings -> More Settings" to "Off".


+-----------------------------------------------------------+
; Parameter Settings for User Entity Instance: counter:inst ;
+---------------------+-------+-----------------------------+
; Parameter Name      ; Value ; Type                        ;
+---------------------+-------+-----------------------------+
; divisor             ; 24000 ; Untyped                     ;
; inner_counter_width ; 16    ; Untyped                     ;
; unit                ; 1001  ; Untyped                     ;
+---------------------+-------+-----------------------------+
Note: In order to hide this table in the UI and the text report file, please set the "Show Parameter Settings Tables in Synthesis Report" option in "Analysis and Synthesis Settings -> More Settings" to "Off".


+-----------------------------------------------------------------+
; Parameter Settings for User Entity Instance: choice1from6:inst8 ;
+----------------+-------+----------------------------------------+
; Parameter Name ; Value ; Type                                   ;
+----------------+-------+----------------------------------------+
; bitwidth       ; 4     ; Untyped                                ;
; digital_num    ; 6     ; Untyped                                ;
+----------------+-------+----------------------------------------+
Note: In order to hide this table in the UI and the text report file, please set the "Show Parameter Settings Tables in Synthesis Report" option in "Analysis and Synthesis Settings -> More Settings" to "Off".


+------------------------------------------------------------+
; Parameter Settings for User Entity Instance: counter:inst2 ;
+---------------------+-------+------------------------------+
; Parameter Name      ; Value ; Type                         ;
+---------------------+-------+------------------------------+
; divisor             ; 10    ; Untyped                      ;
; inner_counter_width ; 4     ; Untyped                      ;
; unit                ; 1001  ; Untyped                      ;
+---------------------+-------+------------------------------+
Note: In order to hide this table in the UI and the text report file, please set the "Show Parameter Settings Tables in Synthesis Report" option in "Analysis and Synthesis Settings -> More Settings" to "Off".


+------------------------------------------------------------+
; Parameter Settings for User Entity Instance: counter:inst3 ;
+---------------------+-------+------------------------------+
; Parameter Name      ; Value ; Type                         ;
+---------------------+-------+------------------------------+
; divisor             ; 6     ; Untyped                      ;
; inner_counter_width ; 4     ; Untyped                      ;
; unit                ; 0101  ; Untyped                      ;
+---------------------+-------+------------------------------+
Note: In order to hide this table in the UI and the text report file, please set the "Show Parameter Settings Tables in Synthesis Report" option in "Analysis and Synthesis Settings -> More Settings" to "Off".


+------------------------------------------------------------+
; Parameter Settings for User Entity Instance: counter:inst4 ;
+---------------------+-------+------------------------------+
; Parameter Name      ; Value ; Type                         ;
+---------------------+-------+------------------------------+
; divisor             ; 10    ; Untyped                      ;
; inner_counter_width ; 4     ; Untyped                      ;
; unit                ; 1001  ; Untyped                      ;
+---------------------+-------+------------------------------+
Note: In order to hide this table in the UI and the text report file, please set the "Show Parameter Settings Tables in Synthesis Report" option in "Analysis and Synthesis Settings -> More Settings" to "Off".


+------------------------------------------------------------+
; Parameter Settings for User Entity Instance: counter:inst5 ;
+---------------------+-------+------------------------------+
; Parameter Name      ; Value ; Type                         ;
+---------------------+-------+------------------------------+
; divisor             ; 6     ; Untyped                      ;
; inner_counter_width ; 4     ; Untyped                      ;
; unit                ; 0101  ; Untyped                      ;
+---------------------+-------+------------------------------+
Note: In order to hide this table in the UI and the text report file, please set the "Show Parameter Settings Tables in Synthesis Report" option in "Analysis and Synthesis Settings -> More Settings" to "Off".


+------------------------------------------------------------+
; Parameter Settings for User Entity Instance: counter:inst7 ;
+---------------------+-------+------------------------------+
; Parameter Name      ; Value ; Type                         ;
+---------------------+-------+------------------------------+
; divisor             ; 10    ; Untyped                      ;
; inner_counter_width ; 4     ; Untyped                      ;
; unit                ; 1001  ; Untyped                      ;
+---------------------+-------+------------------------------+
Note: In order to hide this table in the UI and the text report file, please set the "Show Parameter Settings Tables in Synthesis Report" option in "Analysis and Synthesis Settings -> More Settings" to "Off".


+------------------------------------------------------------+
; Parameter Settings for User Entity Instance: counter:inst6 ;
+---------------------+-------+------------------------------+
; Parameter Name      ; Value ; Type                         ;
+---------------------+-------+------------------------------+
; divisor             ; 10    ; Untyped                      ;
; inner_counter_width ; 4     ; Untyped                      ;
; unit                ; 1001  ; Untyped                      ;
+---------------------+-------+------------------------------+
Note: In order to hide this table in the UI and the text report file, please set the "Show Parameter Settings Tables in Synthesis Report" option in "Analysis and Synthesis Settings -> More Settings" to "Off".

⌨️ 快捷键说明

复制代码 Ctrl + C
搜索代码 Ctrl + F
全屏模式 F11
切换主题 Ctrl + Shift + D
显示快捷键 ?
增大字号 Ctrl + =
减小字号 Ctrl + -