虫虫首页|资源下载|资源专辑|精品软件
登录|注册

conditions

  • Fundamental Limits on a Class of Secure

    Abstract—In the future communication applications, users may obtain their messages that have different importance levels distributively from several available sources, such as distributed storage or even devices belonging to other users. This scenario is the best modeled by the multilevel diversity coding systems (MDCS). To achieve perfect (information-theoretic) secrecy against wiretap channels, this paper investigates the fundamental limits on the secure rate region of the asymmetric MDCS (AMDCS), which include the symmetric case as a special case. Threshold perfect secrecy is added to the AMDCS model. The eavesdropper may have access to any one but not more than one subset of the channels but know nothing about the sources, as long as the size of the subset is not above the security level. The question of whether superposition (source separation) coding is optimal for such an AMDCS with threshold perfect secrecy is answered. A class of secure AMDCS (S-AMDCS) with an arbitrary number of encoders is solved, and it is shown that linear codes are optimal for this class of instances. However, in contrast with the secure symmetric MDCS, superposition is shown to be not optimal for S-AMDCS in general. In addition, necessary conditions on the existence of a secrecy key are determined as a design guideline.

    标签: Fundamental Limits Secure Class on of

    上传时间: 2020-01-04

    上传用户:kddlas

  • AD810

    PRODUCT DESCRIPTION The AD810 is a composite and HDTV compatible, current feedback, video operational amplifier, ideal for use in systems such as multimedia, digital tape recorders and video cameras. The 0.1 dB flatness specification at bandwidth of 30 MHz (G = +2) and the differential gain and phase of 0.02% and 0.04° (NTSC) make the AD810 ideal for any broadcast quality video system. All these specifications are under load conditions of 150 Ω (one 75 Ω back terminated cable). The AD810 is ideal for power sensitive applications such as video cameras, offering a low power supply current of 8.0 mA max. The disable feature reduces the power supply current to only 2.1 mA, while the amplifier is not in use, to conserve power. Furthermore the AD810 is specified over a power supply range of ±5 V to ±15 V.

    标签: 810 AD

    上传时间: 2020-04-19

    上传用户:su1254

  • Millimeter+Wave+V2V+Communications

    Recently millimeter-wave bands have been postu- lated as a means to accommodate the foreseen extreme bandwidth demands in vehicular communications, which result from the dissemination of sensory data to nearby vehicles for enhanced environmental awareness and improved safety level. However, the literature is particularly scarce in regards to principled resource allocation schemes that deal with the challenging radio conditions posed by the high mobility of vehicular scenarios

    标签: Communications Millimeter Wave V2V

    上传时间: 2020-05-22

    上传用户:shancjb

  • Digital Phase Locked Loop

    This work titled A Digital Phase Locked Loop based Signal and Symbol Recovery System for Wireless Channel is intended to serve as a document covering funda- mental concepts and application details related to the design of digital phase locked loop (DPLL) and its importance in wireless communication. It documents some of the work done during the last few years covering rudimentary design issues, complex implementations, and fixing configuration for a range of wireless propa- gation conditions

    标签: Digital Locked Phase Loop

    上传时间: 2020-05-26

    上传用户:shancjb

  • High+Voltage+Protection

    This book is intended to help electric power and telephone company personnel and individuals interested in properly protecting critical tele­ communications circuits and equipment located in high voltage (HV) environments and to improve service reliability while maintaining safe working conditions. Critical telecommunications circuits are often located in HV environments such as electric utility power plants, substations, cell sites on power towers, and standalone telecommuni­ cations facilities such as 911 call centers and mountaintop telecom­ munications sites. 

    标签: Protection Voltage High

    上传时间: 2020-05-27

    上传用户:shancjb

  • Big+Data+Analytics+Strategies

    This is a practical book, to be sure, but it is also a book about hope and posi- tive change. I am quite sincere. The delivery of electricity is deeply rooted in the principle of universal access; when clean, reliable energy is available it contributes to poverty alleviation, improved social conditions, and enhanced economic development. In the developed world, we know this to be true. The digital fabric of our lives is a testimony to the importance of energy security. Across the globe, we have seen the vital contributions that electrification has brought to the development of economies and an enhanced quality of life. Nonetheless, this supreme engineering achievement has languished, and we are deeply challenged.

    标签: Strategies Analytics Data Big

    上传时间: 2020-06-06

    上传用户:shancjb

  • Smart+Grids

    n present power system, the engineers face variety of challenges in planning, construction and operation. In some of the problems, the engineers need to use managerial talents. In system design or upgrading the entire system into automatic control instead of slow response of human operator, the engineers need to exercise more technical knowledge and experience. It is principally the engi- neer’s ability to achieve the success in all respect and provide the reliable and uninterrupted service to the customers. This chapter covers some important areas of the traditional power system that helps engineers to overcome the challenges. It emphasizes the characteristics of the various components of a power system such as generation, transmission, distribution, protection and SCADA system. During normal operating conditions and disturbances, the acquired knowledge will pro- vide the engineers the ability to analyse the performance of the complex system and execute future improvement

    标签: Smart Grids

    上传时间: 2020-06-07

    上传用户:shancjb

  • Transmission+Line+Protection

    Modern power systems involve large amount of investment. An electric power system comprises of generation, transmission, and distribution of electric energy. Growth of power systems has led to very complex networks extended across large areas. In such situations, the proper functioning of a modern power system is heavily dependent upon the healthy operation of the transmission lines within it. Transmission lines are used to transmit a huge amount of power over a long distance. But as these lines are located in the open atmosphere, they are highly affected by different types of abnormal conditions or faults.

    标签: Transmission Protection Line

    上传时间: 2020-06-07

    上传用户:shancjb

  • ISO_16750-5-2010 Part 5:Chemical loads(EN)

    Road vehicles — Environmental conditions and testing for electrical and electronic equipment — Part 5:Chemical loads(EN)ISO16750-5 道路车辆-电气和电子设备的环境条件和测试 第5部分:化学负荷

    标签: iso16750 道路车辆 化学负载

    上传时间: 2021-10-31

    上传用户:GGMD

  • 电子书-RTL Design Style Guide for Verilog HDL540页

    电子书-RTL Design Style Guide for Verilog HDL540页A FF having a fixed input value is generated from the description in the upper portion of Example 2-21. In this case, ’0’ is output when the reset signal is asynchronously input, and ’1’ is output when the START signal rises. Therefore, the FF data input is fixed at the power supply, since the typical value ’1’ is output following the rise of the START signal. When FF input values are fixed, the fixed inputs become untestable and the fault detection rate drops. When implementing a scan design and converting to a scan FF, the scan may not be executed properl not be executed properly, so such descriptions , so such descriptions are not are not recommended. recommended.[1] As in the lower part of Example 2-21, be sure to construct a synchronous type of circuit and ensure that the clock signal is input to the clock pin of the FF. Other than the sample shown in Example 2-21, there are situations where for certain control signals, those that had been switched due to the conditions of an external input will no longer need to be switched, leaving only a FF. If logic exists in a lower level and a fixed value is input from an upper level, the input value of the FF may also end up being fixed as the result of optimization with logic synthesis tools. In a situation like this, while perhaps difficult to completely eliminate, the problem should be avoided as much as possible.

    标签: RTL verilog hdl

    上传时间: 2022-03-21

    上传用户:canderile