  • 模块电源功能性参数指标及测试方法

      模块电源的电气性能是通过一系列测试来呈现的,下列为一般的功能性测试项目,详细说明如下: 电源调整率(Line Regulation) 负载调整率(Load Regulation) 综合调整率(Conmine Regulation) 输出涟波及杂讯(Ripple & Noise) 输入功率及效率(Input Power, Efficiency) 动态负载或暂态负载(Dynamic or Transient Response) 起动(Set-Up)及保持(Hold-Up)时间 常规功能(Functions)测试 1. 电源调整率   电源调整率的定义为电源供应器于输入电压变化时提供其稳定输出电压的能力。测试步骤如下:于待测电源供应器以正常输入电压及负载状况下热机稳定后,分别于低输入电压(Min),正常输入电压(Normal),及高输入电压(Max)下测量并记录其输出电压值。 电源调整率通常以一正常之固定负载(Nominal Load)下,由输入电压变化所造成其输出电压偏差率(deviation)的百分比,如下列公式所示:   [Vo(max)-Vo(min)] / Vo(normal) 2. 负载调整率   负载调整率的定义为开关电源于输出负载电流变化时,提供其稳定输出电压的能力。测试步骤如下:于待测电源供应器以正常输入电压及负载状况下热机稳定后,测量正常负载下之输出电压值,再分别于轻载(Min)、重载(Max)负载下,测量并记录其输出电压值(分别为Vo(max)与Vo(min)),负载调整率通常以正常之固定输入电压下,由负载电流变化所造成其输出电压偏差率的百分比,如下列公式所示:   [Vo(max)-Vo(min)] / Vo(normal)    3. 综合调整率   综合调整率的定义为电源供应器于输入电压与输出负载电流变化时,提供其稳定输出电压的能力。这是电源调整率与负载调整率的综合,此项测试系为上述电源调整率与负载调整率的综合,可提供对电源供应器于改变输入电压与负载状况下更正确的性能验证。 综合调整率用下列方式表示:于输入电压与输出负载电流变化下,其输出电压之偏差量须于规定之上下限电压范围内(即输出电压之上下限绝对值以内)或某一百分比界限内。 4. 输出杂讯   输出杂讯(PARD)系指于输入电压与输出负载电流均不变的情况下,其平均直流输出电压上的周期性与随机性偏差量的电压值。输出杂讯是表示在经过稳压及滤波后的直流输出电压上所有不需要的交流和噪声部份(包含低频之50/60Hz电源倍频信号、高于20 KHz之高频切换信号及其谐波,再与其它之随机性信号所组成)),通常以mVp-p峰对峰值电压为单位来表示。   一般的开关电源的规格均以输出直流输出电压的1%以内为输出杂讯之规格,其频宽为20Hz到20MHz。电源实际工作时最恶劣的状况(如输出负载电流最大、输入电源电压最低等),若电源供应器在恶劣环境状况下,其输出直流电压加上杂讯后之输出瞬时电压,仍能够维持稳定的输出电压不超过输出高低电压界限情形,否则将可能会导致电源电压超过或低于逻辑电路(如TTL电路)之承受电源电压而误动作,进一步造成死机现象。   同时测量电路必须有良好的隔离处理及阻抗匹配,为避免导线上产生不必要的干扰、振铃和驻波,一般都采用双同轴电缆并以50Ω于其端点上,并使用差动式量测方法(可避免地回路之杂讯电流),来获得正确的测量结果。 5. 输入功率与效率   电源供应器的输入功率之定义为以下之公式:   True Power = Pav(watt) = Vrms x Arms x Power Factor 即为对一周期内其输入电压与电流乘积之积分值,需注意的是Watt≠VrmsArms而是Watt=VrmsArmsxP.F.,其中P.F.为功率因素(Power Factor),通常无功率因素校正电路电源供应器的功率因素在0.6~0.7左右,其功率因素为1~0之间。   电源供应器的效率之定义为为输出直流功率之总和与输入功率之比值。效率提供对电源供应器正确工作的验证,若效率超过规定范围,即表示设计或零件材料上有问题,效率太低时会导致散热增加而影响其使用寿命。 6. 动态负载或暂态负载   一个定电压输出的电源,于设计中具备反馈控制回路,能够将其输出电压连续不断地维持稳定的输出电压。由于实际上反馈控制回路有一定的频宽,因此限制了电源供应器对负载电流变化时的反应。若控制回路输入与输出之相移于增益(Unity Gain)为1时,超过180度,则电源供应器之输出便会呈现不稳定、失控或振荡之现象。实际上,电源供应器工作时的负载电流也是动态变化的,而不是始终维持不变(例如硬盘、软驱、CPU或RAM动作等),因此动态负载测试对电源供应器而言是极为重要的。可编程序电子负载可用来模拟电源供应器实际工作时最恶劣的负载情况,如负载电流迅速上升、下降之斜率、周期等,若电源供应器在恶劣负载状况下,仍能够维持稳定的输出电压不产生过高激(Overshoot)或过低(Undershoot)情形,否则会导致电源之输出电压超过负载组件(如TTL电路其输出瞬时电压应介于4.75V至5.25V之间,才不致引起TTL逻辑电路之误动作)之承受电源电压而误动作,进一步造成死机现象。 7. 启动时间与保持时间   启动时间为电源供应器从输入接上电源起到其输出电压上升到稳压范围内为止的时间,以一输出为5V的电源供应器为例,启动时间为从电源开机起到输出电压达到4.75V为止的时间。   保持时间为电源供应器从输入切断电源起到其输出电压下降到稳压范围外为止的时间,以一输出为5V的电源供应器为例,保持时间为从关机起到输出电压低于4.75V为止的时间,一般值为17ms或20ms以上,以避免电力公司供电中于少了半周或一周之状况下而受影响。    8. 其它 在电源具备一些特定保护功能的前提下,还需要进行保护功能测试,如过电压保护(OVP)测试、短路保护测试、过功保护等

    标签: 模块电源 参数 指标 测试方法

    上传时间: 2013-10-22

    上传用户:zouxinwang

  • 优化输电线路 精确测量电压驻波比(VSWR)

    Abstract: Impedance mismatches in a radio-frequency (RF) electrical transmission line cause power loss andreflected energy. Voltage standing wave ratio (VSWR) is a way to measure transmission line imperfections. Thistutorial defines VSWR and explains how it is calculated. Finally, an antenna VSWR monitoring system is shown.

    标签: VSWR 输电线路 精确测量 电压驻波比

    上传时间: 2013-10-19

    上传用户:yuanwenjiao

  • 电阻式温度隔离双输出传送器

    特点(FEATURES) 精确度0.1%满刻度(Accuracy 0.1%F.S.) 多种输入输出选择(Wide selection of input/output range) 三线式接线自动补偿线路阻抗效应(3 wire configuration automatically compensate line resistance effects) 宽范围交直流两用电源设计(Wide input range for auxiliary power) 尺寸小,稳定性高(Dimension small & High stability)

    标签: 电阻式 温度 传送器 隔离

    上传时间: 2013-10-17

    上传用户:Huge_Brother

  • LNK306PG_IC-ON-LINE[1][1].CN

    一个不错的降压芯片

    标签: PG_IC-ON-LINE LNK 306 CN

    上传时间: 2014-01-02

    上传用户:ssj927211

  • 100-15V TO 12V DCDC 原理图 PCB BOM表

    高的工作电压高达100V N双N沟道MOSFET同步驱动 The D810DCDC is a synchronous step-down switching regulator controller that can directly step-down voltages from up to 100V, making it ideal for telecom and automotive applications. The D810DCDC uses a constant on-time valley current control architecture to deliver very low duty cycles with accurate cycle-by-cycle current limit, without requiring a sense resistor. A precise internal reference provides 0.5% DC accuracy. A high bandwidth (25MHz) error amplifi er provides very fast line and load transient response. Large 1Ω gate drivers allow the D810DCDC to drive multiple MOSFETs for higher current applications. The operating frequency is selected by an external resistor and is compensated for variations in VIN and can also be synchronized to an external clock for switching-noise sensitive applications. Integrated bias control generates gate drive power from the input supply during start-up and when an output shortcircuit occurs, with the addition of a small external SOT23 MOSFET. When in regulation, power is derived from the output for higher effi ciency.

    标签: DCDC 100 12V BOM

    上传时间: 2013-10-24

    上传用户:wd450412225

  • 三降压稳压器功能的1-Wire动态可编程输出电压

      The LTC®3569 is a compact power solution for handhelddevices. Its tiny 3mm × 3mm QFN package includesthree buck regulators with individually programmableoutput voltages. One regulator supports load currentsup to 1200mA, while the other two support currents to600mA. Two regulators can be paralleled for increasedload capability. Each current-mode regulator is internallycompensated with excellent load and line regulation. Acomplete 2- or 3-output solution requires a minimumof external passive components.

    标签: Wire 降压稳压器 动态 可编程

    上传时间: 2013-10-11

    上传用户:yxgi5

  • 电网现场作业管理系统的信息化设计

    为了改变目前电网现场作业管理的变电巡检、变电检修试验、输电线路巡检检修等管理系统各自独立运行,信息不能共享,功能、效率受限,建设和维护成本高的现状,提出了采用B/S+C/S构架模式,将各现场作业管理模块和生产MIS(管理系统)集成为一体的现场作业管理系统的设计方案,做到各子系统和生产MIS软硬资源共享,做到同一数据唯一入口、一处录入多处使用。各子系统设备人员等基础信息来源于生产管理系统,各子系统又是生产管理系统的作业数据、缺陷信息的重要来源。经过研究试用成功和推广应用,目前该系统已在江西电网220 kV及以上变电站全面应用。 Abstract:  In order to improve the status that the substation field inspection system, substation equipments maintenance and testing system, power-line inspection and maintenance system are running independent with each other. They can?蒺t share the resource information which accordingly constrains their functions and efficiency, and their construction and maintenance costs are high. This paper introduces a field standardized work management system based on B/S+C/S mode, integrating all field work management systems based on MIS and share the equipments and employee?蒺s data of MIS,the field work data of the sub systems are the source information of MIS, by which the same single data resouce with one-time input can be utilized in multiple places. After the research and testing, this system is triumphantly using in all 220kV and above substations in Jiangxi grid.

    标签: 电网 信息化 管理系统

    上传时间: 2013-11-15

    上传用户:han_zh

  • 使用新电源模块改进表面贴装可制造性

    The latest generation of Texas Instruments (TI) boardmountedpower modules utilizes a pin interconnect technologythat improves surface-mount manufacturability.These modules are produced as a double-sided surfacemount(DSSMT) subassembly, yielding a case-less constructionwith subcomponents located on both sides of theprinted circuit board (PCB). Products produced in theDSSMT outline use the latest high-efficiency topologiesand magnetic-component packaging. This providescustomers with a high-efficiency, ready-to-use switchingpower module in a compact, space-saving package. Bothnonisolated point-of-load (POL) switching regulators andthe isolated dc/dc converter modules are being producedin the DSSMT outline.TI’s plug-in power product line offers power modules inboth through-hole and surface-mount packages. The surfacemountmodules produced in the DSSMT outline use asolid copper interconnect with an integral solder ball fortheir

    标签: 电源模块 可制造性 表面贴装

    上传时间: 2013-10-10

    上传用户:1184599859

  • 逆变电路的基本工作原理

    单相桥式逆变电路为例:S1~S4是桥式电路的4个臂,由电力电子器件及辅助电路组成。S1、S4闭合,S2、S3断开时,负载电压uo为正S1;S1、S4断开,S2、S3闭合时,uo为负,把直流电变成了交流电。改变两组开关切换频率,可改变输出交流电频率。图5-1 逆变电路及其波形举例电阻负载时,负载电流io和uo的波形相同,相位也相同。阻感负载时,io滞后于uo,波形也不同(图5-1b)。t1前:S1、S4通,uo和io均为正。t1时刻断开S1、S4,合上S2、S3,uo变负,但io不能立刻反向。io从电源负极流出,经S2、负载和S3流回正极,负载电感能量向电源反馈,io逐渐减小,t2时刻降为零,之后io才反向并增大 (2)换流方式分类换流——电流从一个支路向另一个支路转移的过程,也称换相。开通:适当的门极驱动信号就可使其开通。关断:全控型器件可通过门极关断。半控型器件晶闸管,必须利用外部条件才能关断,一般在晶闸管电流过零后施加一定时间反压,才能关断。研究换流方式主要是研究如何使器件关断。本章换流及换流方式问题最为全面集中,因此在本章讲述1、器件换流利用全控型器件的自关断能力进行换流(Device Commutation)。2、电网换流由电网提供换流电压称为电网换流(Line Commutation)。可控整流电路、交流调压电路和采用相控方式的交交变频电路,不需器件具有门极可关断能力,也不需要为换流附加元件。3、负载换流由负载提供换流电压称为负载换流(Load Commutation)。负载电流相位超前于负载电压的场合,都可实现负载换流。负载为电容性负载时,负载为同步电动机时,可实现负载换流。

    标签: 逆变电路 基本工作

    上传时间: 2013-10-15

    上传用户:qingdou

  • keil编译错误分析

    一、 main.c(35): warning: #128-D: loop is not reachable from preceding code 原因,前面有一个while(1){ …….} 二、 main.c(54): warning: #1-D: last line of file ends without a newline 少了一个回车在}之后  

    标签: keil 编译 错误

    上传时间: 2014-12-26