📄 ram_256.tan.rpt
字号:
Timing Analyzer report for ram_256
Fri Apr 24 20:00:27 2009
Version 6.0 Build 178 04/27/2006 SJ Full Version
---------------------
; Table of Contents ;
---------------------
1. Legal Notice
2. Timing Analyzer Settings
3. Timing Analyzer Messages
----------------
; Legal Notice ;
----------------
Copyright (C) 1991-2006 Altera Corporation
Your use of Altera Corporation's design tools, logic functions
and other software and tools, and its AMPP partner logic
functions, and any output files any of the foregoing
(including device programming or simulation files), and any
associated documentation or information are expressly subject
to the terms and conditions of the Altera Program License
Subscription Agreement, Altera MegaCore Function License
Agreement, or other applicable license agreement, including,
without limitation, that your use is for the sole purpose of
programming logic devices manufactured by Altera and sold by
Altera or its authorized distributors. Please refer to the
applicable agreement for further details.
+------------------------------------------------------------------------------------------------------+
; Timing Analyzer Settings ;
+-------------------------------------------------------+--------------------+------+----+-------------+
; Option ; Setting ; From ; To ; Entity Name ;
+-------------------------------------------------------+--------------------+------+----+-------------+
; Device Name ; EP2C8Q208C8 ; ; ; ;
; Timing Models ; Final ; ; ; ;
; Number of source nodes to report per destination node ; 10 ; ; ; ;
; Number of destination nodes to report ; 10 ; ; ; ;
; Number of paths to report ; 200 ; ; ; ;
; Report Minimum Timing Checks ; Off ; ; ; ;
; Use Fast Timing Models ; Off ; ; ; ;
; Report IO Paths Separately ; Off ; ; ; ;
; Default hold multicycle ; Same As Multicycle ; ; ; ;
; Cut paths between unrelated clock domains ; On ; ; ; ;
; Cut off read during write signal paths ; On ; ; ; ;
; Cut off feedback from I/O pins ; On ; ; ; ;
; Report Combined Fast/Slow Timing ; Off ; ; ; ;
; Ignore Clock Settings ; Off ; ; ; ;
; Analyze latches as synchronous elements ; On ; ; ; ;
; Enable Recovery/Removal analysis ; Off ; ; ; ;
; Enable Clock Latency ; Off ; ; ; ;
; Use TimeQuest Timing Analyzer ; Off ; ; ; ;
+-------------------------------------------------------+--------------------+------+----+-------------+
+--------------------------+
; Timing Analyzer Messages ;
+--------------------------+
Info: *******************************************************************
Info: Running Quartus II Timing Analyzer
Info: Version 6.0 Build 178 04/27/2006 SJ Full Version
Info: Processing started: Fri Apr 24 20:00:27 2009
Info: Command: quartus_tan --read_settings_files=off --write_settings_files=off ram_256 -c ram_256 --timing_analysis_only
Warning: No paths found for timing analysis
Info: Quartus II Timing Analyzer was successful. 0 errors, 1 warning
Info: Processing ended: Fri Apr 24 20:00:27 2009
Info: Elapsed time: 00:00:00