; Parameter Settings for Inferred Entity Instance: display:inst5|lpm_counter:timeout_rtl_1 ;
+------------------------+-------------------+---------------------------------------------+
; Parameter Name         ; Value             ; Type                                        ;
+------------------------+-------------------+---------------------------------------------+
; AUTO_CARRY_CHAINS      ; ON                ; AUTO_CARRY                                  ;
; IGNORE_CARRY_BUFFERS   ; OFF               ; IGNORE_CARRY                                ;
; AUTO_CASCADE_CHAINS    ; ON                ; AUTO_CASCADE                                ;
; IGNORE_CASCADE_BUFFERS ; OFF               ; IGNORE_CASCADE                              ;
; LPM_WIDTH              ; 6                 ; Untyped                                     ;
; LPM_DIRECTION          ; UP                ; Untyped                                     ;
; LPM_MODULUS            ; 0                 ; Untyped                                     ;
; LPM_AVALUE             ; UNUSED            ; Untyped                                     ;
; LPM_SVALUE             ; UNUSED            ; Untyped                                     ;
; LPM_PORT_UPDOWN        ; PORT_CONNECTIVITY ; Untyped                                     ;
; DEVICE_FAMILY          ; MAX7000S          ; Untyped                                     ;
; CARRY_CHAIN            ; MANUAL            ; Untyped                                     ;
; CARRY_CHAIN_LENGTH     ; 48                ; CARRY_CHAIN_LENGTH                          ;
; NOT_GATE_PUSH_BACK     ; ON                ; NOT_GATE_PUSH_BACK                          ;
; CARRY_CNT_EN           ; SMART             ; Untyped                                     ;
; LABWIDE_SCLR           ; ON                ; Untyped                                     ;
; USE_NEW_VERSION        ; TRUE              ; Untyped                                     ;
; CBXI_PARAMETER         ; NOTHING           ; Untyped                                     ;
+------------------------+-------------------+---------------------------------------------+
Note: In order to hide this table in the UI and the text report file, please set the "Show Parameter Settings Tables in Synthesis Report" option in "Analysis and Synthesis Settings -> More Settings" to "Off".


+---------------------------------------------------------------------------------+
; Parameter Settings for Inferred Entity Instance: counter:inst1|lpm_add_sub:Add0 ;
+------------------------+-------------+------------------------------------------+
; Parameter Name         ; Value       ; Type                                     ;
+------------------------+-------------+------------------------------------------+
; LPM_WIDTH              ; 6           ; Untyped                                  ;
; LPM_REPRESENTATION     ; UNSIGNED    ; Untyped                                  ;
; LPM_DIRECTION          ; ADD         ; Untyped                                  ;
; ONE_INPUT_IS_CONSTANT  ; YES         ; Untyped                                  ;
; LPM_PIPELINE           ; 0           ; Untyped                                  ;
; MAXIMIZE_SPEED         ; 5           ; Untyped                                  ;
; REGISTERED_AT_END      ; 0           ; Untyped                                  ;
; OPTIMIZE_FOR_SPEED     ; 9           ; Untyped                                  ;
; USE_CS_BUFFERS         ; 1           ; Untyped                                  ;
; CARRY_CHAIN            ; MANUAL      ; Untyped                                  ;
; CARRY_CHAIN_LENGTH     ; 48          ; CARRY_CHAIN_LENGTH                       ;
; DEVICE_FAMILY          ; MAX7000S    ; Untyped                                  ;
; USE_WYS                ; OFF         ; Untyped                                  ;
; STYLE                  ; FAST        ; Untyped                                  ;
; CBXI_PARAMETER         ; add_sub_pnh ; Untyped                                  ;
; AUTO_CARRY_CHAINS      ; ON          ; AUTO_CARRY                               ;
; IGNORE_CARRY_BUFFERS   ; OFF         ; IGNORE_CARRY                             ;
; AUTO_CASCADE_CHAINS    ; ON          ; AUTO_CASCADE                             ;
; IGNORE_CASCADE_BUFFERS ; OFF         ; IGNORE_CASCADE                           ;
+------------------------+-------------+------------------------------------------+
Note: In order to hide this table in the UI and the text report file, please set the "Show Parameter Settings Tables in Synthesis Report" option in "Analysis and Synthesis Settings -> More Settings" to "Off".


+-----------------------------------------------------------------------------------+
; Parameter Settings for Inferred Entity Instance: controller:inst|lpm_add_sub:Add2 ;
+------------------------+-------------+--------------------------------------------+
; Parameter Name         ; Value       ; Type                                       ;
+------------------------+-------------+--------------------------------------------+
; LPM_WIDTH              ; 5           ; Untyped                                    ;
; LPM_REPRESENTATION     ; UNSIGNED    ; Untyped                                    ;
; LPM_DIRECTION          ; ADD         ; Untyped                                    ;
; ONE_INPUT_IS_CONSTANT  ; YES         ; Untyped                                    ;
; LPM_PIPELINE           ; 0           ; Untyped                                    ;
; MAXIMIZE_SPEED         ; 5           ; Untyped                                    ;
; REGISTERED_AT_END      ; 0           ; Untyped                                    ;
; OPTIMIZE_FOR_SPEED     ; 9           ; Untyped                                    ;
; USE_CS_BUFFERS         ; 1           ; Untyped                                    ;
; CARRY_CHAIN            ; MANUAL      ; Untyped                                    ;
; CARRY_CHAIN_LENGTH     ; 48          ; CARRY_CHAIN_LENGTH                         ;
; DEVICE_FAMILY          ; MAX7000S    ; Untyped                                    ;
; USE_WYS                ; OFF         ; Untyped                                    ;
; STYLE                  ; FAST        ; Untyped                                    ;
; CBXI_PARAMETER         ; add_sub_uch ; Untyped                                    ;
; AUTO_CARRY_CHAINS      ; ON          ; AUTO_CARRY                                 ;
; IGNORE_CARRY_BUFFERS   ; OFF         ; IGNORE_CARRY                               ;
; AUTO_CASCADE_CHAINS    ; ON          ; AUTO_CASCADE                               ;
; IGNORE_CASCADE_BUFFERS ; OFF         ; IGNORE_CASCADE                             ;
+------------------------+-------------+--------------------------------------------+
Note: In order to hide this table in the UI and the text report file, please set the "Show Parameter Settings Tables in Synthesis Report" option in "Analysis and Synthesis Settings -> More Settings" to "Off".


+------------------------------------------------------------------------------------+
; Parameter Settings for Inferred Entity Instance: predevide2:inst9|lpm_add_sub:Add0 ;
+------------------------+-------------+---------------------------------------------+
; Parameter Name         ; Value       ; Type                                        ;
+------------------------+-------------+---------------------------------------------+
; LPM_WIDTH              ; 21          ; Untyped                                     ;
; LPM_REPRESENTATION     ; UNSIGNED    ; Untyped                                     ;
; LPM_DIRECTION          ; ADD         ; Untyped                                     ;
; ONE_INPUT_IS_CONSTANT  ; YES         ; Untyped                                     ;
; LPM_PIPELINE           ; 0           ; Untyped                                     ;
; MAXIMIZE_SPEED         ; 5           ; Untyped                                     ;
; REGISTERED_AT_END      ; 0           ; Untyped                                     ;
; OPTIMIZE_FOR_SPEED     ; 9           ; Untyped                                     ;
; USE_CS_BUFFERS         ; 1           ; Untyped                                     ;
; CARRY_CHAIN            ; MANUAL      ; Untyped                                     ;
; CARRY_CHAIN_LENGTH     ; 48          ; CARRY_CHAIN_LENGTH                          ;
; DEVICE_FAMILY          ; MAX7000S    ; Untyped                                     ;
; USE_WYS                ; OFF         ; Untyped                                     ;
; STYLE                  ; FAST        ; Untyped                                     ;
; CBXI_PARAMETER         ; add_sub_6ph ; Untyped                                     ;
; AUTO_CARRY_CHAINS      ; ON          ; AUTO_CARRY                                  ;
; IGNORE_CARRY_BUFFERS   ; OFF         ; IGNORE_CARRY                                ;
; AUTO_CASCADE_CHAINS    ; ON          ; AUTO_CASCADE                                ;
; IGNORE_CASCADE_BUFFERS ; OFF         ; IGNORE_CASCADE                              ;
+------------------------+-------------+---------------------------------------------+
Note: In order to hide this table in the UI and the text report file, please set the "Show Parameter Settings Tables in Synthesis Report" option in "Analysis and Synthesis Settings -> More Settings" to "Off".


+-------------------------------+
; Analysis & Synthesis Messages ;
+-------------------------------+
Info: *******************************************************************
Info: Running Quartus II Analysis & Synthesis
    Info: Version 7.2 Build 151 09/26/2007 SJ Full Version
    Info: Processing started: Mon May 05 08:22:01 2008
Info: Command: quartus_map --read_settings_files=on --write_settings_files=off light -c light
Info: Found 2 design units, including 1 entities, in source file controller.vhd
    Info: Found design unit 1: controller-behavior
    Info: Found entity 1: controller
Info: Found 2 design units, including 1 entities, in source file counter.vhd
    Info: Found design unit 1: counter-behavior
    Info: Found entity 1: counter
Info: Found 2 design units, including 1 entities, in source file display.vhd
    Info: Found design unit 1: display-decoder
    Info: Found entity 1: display
Info: Found 2 design units, including 1 entities, in source file fenwei.vhd
    Info: Found design unit 1: fenwei-behavior
    Info: Found entity 1: fenwei
Info: Found 2 design units, including 1 entities, in source file FreDevide10.vhd
    Info: Found design unit 1: FreDevide10-Devider
    Info: Found entity 1: FreDevide10
Info: Found 2 design units, including 1 entities, in source file predevide2.vhd
    Info: Found design unit 1: predevide2-Devider
    Info: Found entity 1: predevide2
Info: Found 1 design units, including 1 entities, in source file light.bdf
    Info: Found entity 1: light
Info: Elaborating entity "light" for the top level hierarchy
Warning: Processing legacy GDF or BDF entity "light" with Max+Plus II bus and instance naming rules
Info: Elaborating entity "controller" for hierarchy "controller:inst"
Warning (10034): Output port "numb[4]" at controller.vhd(8) has no driver
Warning (10034): Output port "numb[3]" at controller.vhd(8) has no driver
Warning (10034): Output port "numb[2]" at controller.vhd(8) has no driver
Warning (10034): Output port "numb[1]" at controller.vhd(8) has no driver
Warning (10034): Output port "numb[0]" at controller.vhd(8) has no driver
Info: Elaborating entity "FreDevide10" for hierarchy "FreDevide10:inst8"
Info: Elaborating entity "predevide2" for hierarchy "predevide2:inst9"
Info: Elaborating entity "counter" for hierarchy "counter:inst1"
Info: Elaborating entity "display" for hierarchy "display:inst2"
Info: Elaborating entity "fenwei" for hierarchy "fenwei:inst3"
Info: Power-up level of register "display:inst5|display[0]" is not specified -- using power-up level of High to minimize register
Warning (14130): Reduced register "display:inst5|display[0]" with stuck data_in port to stuck value VCC
Info: Power-up level of register "display:inst2|display[0]" is not specified -- using power-up level of High to minimize register