📄 image.map.qmsg
字号:
{ "Info" "ICDB_SGATE_CDB_INFO_USING_PWRUP_DC" "image1:U2\|mode High " "Info: Power-up level of register \"image1:U2\|mode\" is not specified -- using power-up level of High to minimize register" { } { { "image1.vhd" "" { Text "D:/study/毕业设计/韩健程序/cyclic/image1.vhd" 69 -1 0 } } } 0}
{ "Warning" "WCDB_SGATE_CDB_WARN_TRIVIAL_REG" "image1:U2\|mode data_in VCC " "Warning: Reduced register \"image1:U2\|mode\" with stuck data_in port to stuck value VCC" { } { { "image1.vhd" "" { Text "D:/study/毕业设计/韩健程序/cyclic/image1.vhd" 69 -1 0 } } } 0}
{ "Info" "ICDB_SGATE_CDB_INFO_USING_PWRUP_DC" "image1:U2\|outsel High " "Info: Power-up level of register \"image1:U2\|outsel\" is not specified -- using power-up level of High to minimize register" { } { { "image1.vhd" "" { Text "D:/study/毕业设计/韩健程序/cyclic/image1.vhd" 81 -1 0 } } } 0}
{ "Warning" "WCDB_SGATE_CDB_WARN_TRIVIAL_REG" "image1:U2\|outsel data_in VCC " "Warning: Reduced register \"image1:U2\|outsel\" with stuck data_in port to stuck value VCC" { } { { "image1.vhd" "" { Text "D:/study/毕业设计/韩健程序/cyclic/image1.vhd" 81 -1 0 } } } 0}
{ "Info" "ICDB_SGATE_CDB_INFO_USING_PWRUP_DC" "image1:U2\|size\[3\] High " "Info: Power-up level of register \"image1:U2\|size\[3\]\" is not specified -- using power-up level of High to minimize register" { } { { "image1.vhd" "" { Text "D:/study/毕业设计/韩健程序/cyclic/image1.vhd" 77 -1 0 } } } 0}
{ "Warning" "WCDB_SGATE_CDB_WARN_TRIVIAL_REG" "image1:U2\|size\[3\] data_in VCC " "Warning: Reduced register \"image1:U2\|size\[3\]\" with stuck data_in port to stuck value VCC" { } { { "image1.vhd" "" { Text "D:/study/毕业设计/韩健程序/cyclic/image1.vhd" 77 -1 0 } } } 0}
{ "Info" "ICDB_SGATE_CDB_INFO_USING_PWRUP_DC" "image1:U2\|size\[2\] High " "Info: Power-up level of register \"image1:U2\|size\[2\]\" is not specified -- using power-up level of High to minimize register" { } { { "image1.vhd" "" { Text "D:/study/毕业设计/韩健程序/cyclic/image1.vhd" 77 -1 0 } } } 0}
{ "Warning" "WCDB_SGATE_CDB_WARN_TRIVIAL_REG" "image1:U2\|size\[2\] data_in VCC " "Warning: Reduced register \"image1:U2\|size\[2\]\" with stuck data_in port to stuck value VCC" { } { { "image1.vhd" "" { Text "D:/study/毕业设计/韩健程序/cyclic/image1.vhd" 77 -1 0 } } } 0}
{ "Warning" "WCDB_SGATE_CDB_WARN_TRIVIAL_REG" "image1:U2\|chose\[2\] data_in GND " "Warning: Reduced register \"image1:U2\|chose\[2\]\" with stuck data_in port to stuck value GND" { } { { "image1.vhd" "" { Text "D:/study/毕业设计/韩健程序/cyclic/image1.vhd" 78 -1 0 } } } 0}
{ "Warning" "WCDB_SGATE_CDB_WARN_TRIVIAL_REG" "image1:U2\|chose\[1\] data_in GND " "Warning: Reduced register \"image1:U2\|chose\[1\]\" with stuck data_in port to stuck value GND" { } { { "image1.vhd" "" { Text "D:/study/毕业设计/韩健程序/cyclic/image1.vhd" 78 -1 0 } } } 0}
{ "Info" "ICDB_SGATE_CDB_INFO_USING_PWRUP_DC" "image1:U2\|chose\[0\] High " "Info: Power-up level of register \"image1:U2\|chose\[0\]\" is not specified -- using power-up level of High to minimize register" { } { { "image1.vhd" "" { Text "D:/study/毕业设计/韩健程序/cyclic/image1.vhd" 78 -1 0 } } } 0}
{ "Warning" "WCDB_SGATE_CDB_WARN_TRIVIAL_REG" "image1:U2\|chose\[0\] data_in VCC " "Warning: Reduced register \"image1:U2\|chose\[0\]\" with stuck data_in port to stuck value VCC" { } { { "image1.vhd" "" { Text "D:/study/毕业设计/韩健程序/cyclic/image1.vhd" 78 -1 0 } } } 0}
{ "Warning" "WCDB_SGATE_CDB_WARN_TRIVIAL_REG" "image1:U2\|refresh\[1\] data_in GND " "Warning: Reduced register \"image1:U2\|refresh\[1\]\" with stuck data_in port to stuck value GND" { } { { "image1.vhd" "" { Text "D:/study/毕业设计/韩健程序/cyclic/image1.vhd" 79 -1 0 } } } 0}
{ "Warning" "WCDB_SGATE_CDB_WARN_TRIVIAL_REG" "image1:U2\|refresh\[0\] data_in GND " "Warning: Reduced register \"image1:U2\|refresh\[0\]\" with stuck data_in port to stuck value GND" { } { { "image1.vhd" "" { Text "D:/study/毕业设计/韩健程序/cyclic/image1.vhd" 79 -1 0 } } } 0}
{ "Warning" "WCDB_SGATE_CDB_WARN_TRIVIAL_REG" "image1:U2\|pos\[3\] data_in GND " "Warning: Reduced register \"image1:U2\|pos\[3\]\" with stuck data_in port to stuck value GND" { } { { "image1.vhd" "" { Text "D:/study/毕业设计/韩健程序/cyclic/image1.vhd" 80 -1 0 } } } 0}
{ "Warning" "WCDB_SGATE_CDB_WARN_TRIVIAL_REG" "image1:U2\|pos\[2\] data_in GND " "Warning: Reduced register \"image1:U2\|pos\[2\]\" with stuck data_in port to stuck value GND" { } { { "image1.vhd" "" { Text "D:/study/毕业设计/韩健程序/cyclic/image1.vhd" 80 -1 0 } } } 0}
⌨️ 快捷键说明
复制代码
Ctrl + C
搜索代码
Ctrl + F
全屏模式
F11
切换主题
Ctrl + Shift + D
显示快捷键
?
增大字号
Ctrl + =
减小字号
Ctrl + -