⭐ 欢迎来到虫虫下载站! | 📦 资源下载 📁 资源专辑 ℹ️ 关于我们
⭐ 虫虫下载站

📄 ddsok.qsf

📁 DDS信号发生器
💻 QSF
字号:
# Copyright (C) 1991-2006 Altera Corporation
# Your use of Altera Corporation's design tools, logic functions 
# and other software and tools, and its AMPP partner logic 
# functions, and any output files any of the foregoing 
# (including device programming or simulation files), and any 
# associated documentation or information are expressly subject 
# to the terms and conditions of the Altera Program License 
# Subscription Agreement, Altera MegaCore Function License 
# Agreement, or other applicable license agreement, including, 
# without limitation, that your use is for the sole purpose of 
# programming logic devices manufactured by Altera and sold by 
# Altera or its authorized distributors.  Please refer to the 
# applicable agreement for further details.


# The default values for assignments are stored in the file
#		ddsok_assignment_defaults.qdf
# If this file doesn't exist, and for assignments not listed, see file
#		assignment_defaults.qdf

# Altera recommends that you do not modify this file. This
# file is updated automatically by the Quartus II software
# and any changes you make may be lost or overwritten.


set_global_assignment -name FAMILY Cyclone
set_global_assignment -name DEVICE EP1C12Q240C8
set_global_assignment -name TOP_LEVEL_ENTITY ddsok
set_global_assignment -name ORIGINAL_QUARTUS_VERSION 6.0
set_global_assignment -name PROJECT_CREATION_TIME_DATE "20:07:55  MAY 17, 2007"
set_global_assignment -name LAST_QUARTUS_VERSION "6.0 SP1"
set_global_assignment -name VHDL_FILE ddsok.vhd
set_global_assignment -name VHDL_FILE data_rom.vhd
set_global_assignment -name VHDL_FILE adderful1.vhd
set_global_assignment -name CYCLONE_CONFIGURATION_DEVICE EPCS4
set_global_assignment -name RESERVE_ASDO_AFTER_CONFIGURATION "AS INPUT TRI-STATED"
set_global_assignment -name DEVICE_MIGRATION_LIST EP1C12Q240C8
set_location_assignment PIN_2 -to wp[0]
set_location_assignment PIN_3 -to wp[1]
set_location_assignment PIN_28 -to clok
set_location_assignment PIN_5 -to fout[0]
set_location_assignment PIN_6 -to fout[1]
set_location_assignment PIN_7 -to fout[2]
set_location_assignment PIN_8 -to fout[3]
set_location_assignment PIN_11 -to fout[4]
set_location_assignment PIN_12 -to fout[5]
set_location_assignment PIN_13 -to fout[6]
set_location_assignment PIN_14 -to fout[7]
set_location_assignment PIN_16 -to fword[0]
set_location_assignment PIN_17 -to fword[1]
set_location_assignment PIN_18 -to fword[2]
set_location_assignment PIN_19 -to fword[3]
set_location_assignment PIN_41 -to fword[4]
set_location_assignment PIN_44 -to fword[7]
set_location_assignment PIN_43 -to fword[6]
set_global_assignment -name SIGNALTAP_FILE ddsok.stp
set_global_assignment -name ENABLE_SIGNALTAP ON
set_global_assignment -name USE_SIGNALTAP_FILE ddsok.stp
set_global_assignment -name SLD_NODE_CREATOR_ID 110 -section_id cnts
set_global_assignment -name SLD_NODE_ENTITY_NAME sld_signaltap -section_id cnts
set_instance_assignment -name CONNECT_TO_SLD_NODE_ENTITY_PORT acq_clk -to clok -section_id cnts
set_instance_assignment -name CONNECT_TO_SLD_NODE_ENTITY_PORT trigger_in -to fword[0] -section_id cnts
set_global_assignment -name SLD_NODE_PARAMETER_ASSIGNMENT "SLD_NODE_INFO=536899072" -section_id cnts
set_global_assignment -name SLD_NODE_PARAMETER_ASSIGNMENT "SLD_POWER_UP_TRIGGER=0" -section_id cnts
set_global_assignment -name SLD_NODE_PARAMETER_ASSIGNMENT "SLD_TRIGGER_LEVEL=1" -section_id cnts
set_global_assignment -name SLD_NODE_PARAMETER_ASSIGNMENT "SLD_SAMPLE_DEPTH=1024" -section_id cnts
set_global_assignment -name SLD_NODE_PARAMETER_ASSIGNMENT "SLD_MEM_ADDRESS_BITS=10" -section_id cnts
set_global_assignment -name SLD_NODE_PARAMETER_ASSIGNMENT "SLD_TRIGGER_IN_ENABLED=1" -section_id cnts
set_global_assignment -name SLD_NODE_PARAMETER_ASSIGNMENT "SLD_ADVANCED_TRIGGER_ENTITY=basic,1," -section_id cnts
set_global_assignment -name SLD_NODE_PARAMETER_ASSIGNMENT "SLD_TRIGGER_LEVEL_PIPELINE=1" -section_id cnts
set_global_assignment -name SLD_NODE_PARAMETER_ASSIGNMENT "SLD_ENABLE_ADVANCED_TRIGGER=0" -section_id cnts
set_location_assignment PIN_42 -to fword[5]
set_instance_assignment -name CONNECT_TO_SLD_NODE_ENTITY_PORT acq_trigger_in[0] -to fout[0] -section_id cnts
set_instance_assignment -name CONNECT_TO_SLD_NODE_ENTITY_PORT acq_trigger_in[1] -to fout[1] -section_id cnts
set_instance_assignment -name CONNECT_TO_SLD_NODE_ENTITY_PORT acq_trigger_in[2] -to fout[2] -section_id cnts
set_instance_assignment -name CONNECT_TO_SLD_NODE_ENTITY_PORT acq_trigger_in[3] -to fout[3] -section_id cnts
set_instance_assignment -name CONNECT_TO_SLD_NODE_ENTITY_PORT acq_trigger_in[4] -to fout[4] -section_id cnts
set_instance_assignment -name CONNECT_TO_SLD_NODE_ENTITY_PORT acq_trigger_in[5] -to fout[5] -section_id cnts
set_instance_assignment -name CONNECT_TO_SLD_NODE_ENTITY_PORT acq_trigger_in[6] -to fout[6] -section_id cnts
set_instance_assignment -name CONNECT_TO_SLD_NODE_ENTITY_PORT acq_trigger_in[7] -to fout[7] -section_id cnts
set_instance_assignment -name CONNECT_TO_SLD_NODE_ENTITY_PORT acq_trigger_in[8] -to fword[0] -section_id cnts
set_instance_assignment -name CONNECT_TO_SLD_NODE_ENTITY_PORT acq_trigger_in[9] -to fword[1] -section_id cnts
set_instance_assignment -name CONNECT_TO_SLD_NODE_ENTITY_PORT acq_trigger_in[10] -to fword[2] -section_id cnts
set_instance_assignment -name CONNECT_TO_SLD_NODE_ENTITY_PORT acq_trigger_in[11] -to fword[3] -section_id cnts
set_instance_assignment -name CONNECT_TO_SLD_NODE_ENTITY_PORT acq_trigger_in[12] -to fword[4] -section_id cnts
set_instance_assignment -name CONNECT_TO_SLD_NODE_ENTITY_PORT acq_trigger_in[13] -to fword[5] -section_id cnts
set_instance_assignment -name CONNECT_TO_SLD_NODE_ENTITY_PORT acq_trigger_in[14] -to fword[6] -section_id cnts
set_instance_assignment -name CONNECT_TO_SLD_NODE_ENTITY_PORT acq_trigger_in[15] -to fword[7] -section_id cnts
set_instance_assignment -name CONNECT_TO_SLD_NODE_ENTITY_PORT acq_data_in[0] -to fout[0] -section_id cnts
set_instance_assignment -name CONNECT_TO_SLD_NODE_ENTITY_PORT acq_data_in[1] -to fout[1] -section_id cnts
set_instance_assignment -name CONNECT_TO_SLD_NODE_ENTITY_PORT acq_data_in[2] -to fout[2] -section_id cnts
set_instance_assignment -name CONNECT_TO_SLD_NODE_ENTITY_PORT acq_data_in[3] -to fout[3] -section_id cnts
set_instance_assignment -name CONNECT_TO_SLD_NODE_ENTITY_PORT acq_data_in[4] -to fout[4] -section_id cnts
set_instance_assignment -name CONNECT_TO_SLD_NODE_ENTITY_PORT acq_data_in[5] -to fout[5] -section_id cnts
set_instance_assignment -name CONNECT_TO_SLD_NODE_ENTITY_PORT acq_data_in[6] -to fout[6] -section_id cnts
set_instance_assignment -name CONNECT_TO_SLD_NODE_ENTITY_PORT acq_data_in[7] -to fout[7] -section_id cnts
set_instance_assignment -name CONNECT_TO_SLD_NODE_ENTITY_PORT acq_data_in[8] -to fword[0] -section_id cnts
set_instance_assignment -name CONNECT_TO_SLD_NODE_ENTITY_PORT acq_data_in[9] -to fword[1] -section_id cnts
set_instance_assignment -name CONNECT_TO_SLD_NODE_ENTITY_PORT acq_data_in[10] -to fword[2] -section_id cnts
set_instance_assignment -name CONNECT_TO_SLD_NODE_ENTITY_PORT acq_data_in[11] -to fword[3] -section_id cnts
set_instance_assignment -name CONNECT_TO_SLD_NODE_ENTITY_PORT acq_data_in[12] -to fword[4] -section_id cnts
set_instance_assignment -name CONNECT_TO_SLD_NODE_ENTITY_PORT acq_data_in[13] -to fword[5] -section_id cnts
set_instance_assignment -name CONNECT_TO_SLD_NODE_ENTITY_PORT acq_data_in[14] -to fword[6] -section_id cnts
set_instance_assignment -name CONNECT_TO_SLD_NODE_ENTITY_PORT acq_data_in[15] -to fword[7] -section_id cnts
set_global_assignment -name SLD_NODE_PARAMETER_ASSIGNMENT "SLD_DATA_BITS=16" -section_id cnts
set_global_assignment -name SLD_NODE_PARAMETER_ASSIGNMENT "SLD_TRIGGER_BITS=16" -section_id cnts
set_global_assignment -name SLD_NODE_PARAMETER_ASSIGNMENT "SLD_INVERSION_MASK=0000000000000000000000000000000000000000000000000000000000000000000" -section_id cnts
set_global_assignment -name SLD_NODE_PARAMETER_ASSIGNMENT "SLD_INVERSION_MASK_LENGTH=67" -section_id cnts
set_global_assignment -name SLD_NODE_PARAMETER_ASSIGNMENT "SLD_NODE_CRC_LOWORD=56471" -section_id cnts
set_global_assignment -name SLD_NODE_PARAMETER_ASSIGNMENT "SLD_NODE_CRC_HIWORD=62577" -section_id cnts
set_global_assignment -name SLD_NODE_PARAMETER_ASSIGNMENT "SLD_DATA_BIT_CNTR_BITS=4" -section_id cnts
set_global_assignment -name VHDL_FILE ../message/jishu.vhd

⌨️ 快捷键说明

复制代码 Ctrl + C
搜索代码 Ctrl + F
全屏模式 F11
切换主题 Ctrl + Shift + D
显示快捷键 ?
增大字号 Ctrl + =
减小字号 Ctrl + -