As the performance of many handheld devices approachesthat of laptop computers, design complexity also increases.Chief among them is thermal management—how doyou meet increasing performance demands while keepinga compact and small product cool in the user’s hand?For instance, as battery capacities inevitably increase,charge currents will also increase to maintain or improvetheir charge times. Traditional linear regulator-based batterychargers will not be able to meet the charge currentand effi ciency demands necessary to allow a product torun cool. What is needed is a switching-based chargerthat takes just about the same amount of space as a linearsolution—but without the heat.
上传时间: 2013-11-23
上传用户:lu2767
Automotive batteries, industrial power supplies, distributedsupplies and wall transformers are all sources ofwide-ranging high voltage inputs. The easiest way to stepdown these sources is with a high voltage monolithicstep-down regulator that can directly accept a wide inputrange and produce a well-regulated output. The LT®3493accepts inputs from 3.6V to 36V and LT3481 acceptsinputs from 3.6V to 34V. Both provide excellent lineand load regulation and dynamic response. The LT3481offers a high effi ciency solution over a wide load range andkeeps the output ripple low during Burst Mode® operationwhile the LT3493 provides a tiny solution with minimalexternal components. The LT3493 operates at 750kHzand the LT3481 has adjustable frequency from 300kHzto 2.8MHz. High frequency operation enables the use ofsmall, low cost inductors and ceramic capacitors.
上传时间: 2014-12-24
上传用户:Pzj
The LTC®3562 quad output step-down regulator is designedfor multicore handheld microprocessor applications thatoperate from a single Li-Ion battery. Its four monolithic, higheffi ciency buck regulators support Intel’s mobile CPU P-Stateand C-State energy saving operating modes. The outputvoltages are independently controllable via I2C, and eachoutput can be independently started and shut down. Designerscan choose from power saving pulse-skipping mode orBurst Mode® operation, or select low noise LDO mode. Thespace-saving LTC3562 is available in a 3mm × 3mm QFNpackage and requires few external components.
上传时间: 2013-10-07
上传用户:1583060504
Alkaline batteries are convenient because they’re easy tofi nd and relatively inexpensive, making them the powersource of choice for portable instruments and devicesused for outdoor recreation. Their long shelf life alsomakes them an excellent choice for emergency equipmentthat may see infrequent use but must be ready to go on amoment’s notice. It is important that the DC/DC convertersin portable devices operate over the widest possiblebattery voltage range to extend battery run time, and thussave the user from frequent battery replacement.
上传时间: 2014-12-24
上传用户:569342831
The LTC®3569 is a compact power solution for handhelddevices. Its tiny 3mm × 3mm QFN package includesthree buck regulators with individually programmableoutput voltages. One regulator supports load currentsup to 1200mA, while the other two support currents to600mA. Two regulators can be paralleled for increasedload capability. Each current-mode regulator is internallycompensated with excellent load and line regulation. Acomplete 2- or 3-output solution requires a minimumof external passive components.
上传时间: 2013-10-11
上传用户:yxgi5
Industrial remote monitoring systems and keep-alivecircuits spend most of their time in standby mode. Manyof these systems also depend on battery power, so powersupply effi ciency in standby state is very important tomaximize battery life. The LT®8410/-1 high effi ciencyboost converter is ideal for these systems, requiringonly 8.5μA of quiescent current in standby mode. Thedevice integrates high value (12.4M/0.4M) output feedbackresistors, signifi cantly reducing input current whenthe output is in regulation with no load. Other featuresinclude an integrated 40V switch and Schottky diode,output disconnect with current limit, built in soft-start,overvoltage protection and a wide input range, all in atiny 8-pin 2mm × 2mm DFN package.
上传时间: 2013-11-23
上传用户:新手无忧
The LTC3546 is a dual output current mode buck regulatorwith fl exible output current partitioning. Beyondthe advantages normally associated with dual outputregulators (reduced size, cost, EMI and part count, withimproved effi ciency), the LTC3546’s outputs can bepartitioned for either 3A and 1A outputs, or two 2A outputs.This increases its application range and simplifi esmultiple supply rail designs. A confi gurable Burst Mode®clamp for each output sets the current transition levelbetween Burst Mode operation and forced continuousconduction mode to optimize effi ciency over the entireoutput range. An adjustable switching frequency up to4MHz and internal power MOSFET switches allow forsmall and compact footprints.
上传时间: 2013-11-04
上传用户:yxgi5
The LTC®3610 is a high power monolithic synchronousstep-down DC/DC regulator that can deliver up to 12Aof continuous output current from a 4V to 24V (28Vmaximum) input supply. It is a member of a high currentmonolithic regulator family (see Table 1) that featuresintegrated low RDS(ON) N-channel top and bottomMOSFETs. This results in a high effi ciency and highpower density solution with few external components.This regulator family uses a constant on-time valleycurrent mode architecture that is capable of operatingat very low duty cycles at high frequency and with veryfast transient response. All are available in low profi le(0.9mm max) QFN packages.
上传时间: 2013-11-07
上传用户:moerwang
For a variety of reasons, it is desirable to charge batteriesas rapidly as possible. At the same time, overchargingmust be limited to prolong battery life. Such limitation ofovercharging depends on factors such as the choice ofcharge termination technique and the use of multi-rate/multi-stage charging schemes. The majority of batterycharger ICs available today lock the user into one fixedcharging regimen, with at best a limited number ofcustomization options to suit a variety of application needsor battery types. The LTC®1325 addresses these shortcomingsby providing the user with all the functionalblocks needed to implement a simple but highly flexiblebattery charger (see Figure 1) which not only addressesthe issue of charging batteries but also those of batteryconditioning and capacity monitoring.
上传时间: 2013-10-19
上传用户:royzhangsz
为了改变目前电网现场作业管理的变电巡检、变电检修试验、输电线路巡检检修等管理系统各自独立运行,信息不能共享,功能、效率受限,建设和维护成本高的现状,提出了采用B/S+C/S构架模式,将各现场作业管理模块和生产MIS(管理系统)集成为一体的现场作业管理系统的设计方案,做到各子系统和生产MIS软硬资源共享,做到同一数据唯一入口、一处录入多处使用。各子系统设备人员等基础信息来源于生产管理系统,各子系统又是生产管理系统的作业数据、缺陷信息的重要来源。经过研究试用成功和推广应用,目前该系统已在江西电网220 kV及以上变电站全面应用。 Abstract: In order to improve the status that the substation field inspection system, substation equipments maintenance and testing system, power-line inspection and maintenance system are running independent with each other. They can?蒺t share the resource information which accordingly constrains their functions and efficiency, and their construction and maintenance costs are high. This paper introduces a field standardized work management system based on B/S+C/S mode, integrating all field work management systems based on MIS and share the equipments and employee?蒺s data of MIS,the field work data of the sub systems are the source information of MIS, by which the same single data resouce with one-time input can be utilized in multiple places. After the research and testing, this system is triumphantly using in all 220kV and above substations in Jiangxi grid.
上传时间: 2013-11-15
上传用户:han_zh