  • AHP toolbox AHPCALC Perform a complete AHP calculation. AHPHIER One-step hierarchic

    AHP toolbox AHPCALC Perform a complete AHP calculation. AHPHIER One-step hierarchical assembly of AHP weighting vector. AHPREORDER internal reordering function called by AHPCALC. AHPVECTOR Calculate the AHP ranking or weighting vector from an AHP reciproal matrix. AHPMAKEMAT Turn a vector of comparisons into an AHP reciprocal matrix. Copyright (C) 2001 Michael J. Scott

    标签: calculation hierarchic AHP One-step

    上传时间: 2013-11-28

    上传用户:PresidentHuang

  • LatentSVM论文

    The object detector described below has been initially proposed by P.F. Felzenszwalb in [Felzenszwalb2010]. It is based on a Dalal-Triggs detector that uses a single filter on histogram of oriented gradients (HOG) features to represent an object category. This detector uses a sliding window approach, where a filter is applied at all positions and scales of an image. The first innovation is enriching the Dalal-Triggs model using a star-structured part-based model defined by a “root” filter (analogous to the Dalal-Triggs filter) plus a set of parts filters and associated deformation models. The score of one of star models at a particular position and scale within an image is the score of the root filter at the given location plus the sum over parts of the maximum, over placements of that part, of the part filter score on its location minus a deformation cost easuring the deviation of the part from its ideal location relative to the root. Both root and part filter scores are defined by the dot product between a filter (a set of weights) and a subwindow of a feature pyramid computed from the input image. Another improvement is a representation of the class of models by a mixture of star models. The score of a mixture model at a particular position and scale is the maximum over components, of the score of that component model at the given location.

    标签: 计算机视觉

    上传时间: 2015-03-15

    上传用户:sb_zhang

  • 自动导引小车调度(外文)

    Guided vehicles (GVs) are commonly used for the internal transportation of loads in warehouses, production plants and terminals. These guided vehicles can be routed with a variety of vehicle dispatching rules in an attempt to meet performance criteria such as minimizing the average load waiting times. In this research, we use simulation models of three companies to evaluate the performance of several real-time vehicle dispatching rules, in part described in the literature. It appears that there is a clear difference in average load waiting time between the different dispatching rules in the different environments. Simple rules, based on load and vehicle proximity (distance-based) perform best for all cases. The penalty for this is a relatively high maximum load waiting time. A distance-based rule with time truncation, giving more priority to loads that have to wait longer than a time threshold, appears to yield the best possible overall performance. A rule that particularly considers load-waiting time performs poor overall. We also show that using little pre-arrival information of loads leads to a significant improvement in the performance of the dispatching rules without changing their performance ranking.

    标签: Testing and classifying vehicle dispatching rules in three real-world settings

    上传时间: 2016-04-01

    上传用户:五块钱的油条

  • Fuel+Cell+Micro-grids

    The solid high-polymer-film-type fuel cell (PEM-FC) system is used as the power supply equipment for transportation and replaces an internal combustion engine. A reduction of the environmental load is expected through the cogeneration system’s (CGS) use of the PEM-FC system as a distributed power supply to individual houses, apartments, and so forth [1–3]. The growing use of distributed power systems, such as fuel cells, the reduction of power-transmission losses, and an increase of waste heat recovery are expected. Therefore, the reduction of carbon- dioxide emission is also expected as compared to conventional energy supply methods using commercial electric power. 

    标签: Micro-grids Fuel Cell

    上传时间: 2020-06-06

    上传用户:shancjb

  • Plug In Electric Vehicles in Smart Grids

    Plug in Electric Vehicles (PEVs) use energy storages usually in the form of battery banks that are designed to be recharged using utility grid power. One category of PEVs are Electric Vehicles (EVs) without an internal-combustion (IC) engine where the energy stored in the battery bank is the only source of power to drive the vehicle. These are also referred as Battery Electric Vehicles (BEVs). The second category of PEVs, which is more commercialized than the EVs, is the Plug in

    标签: Electric Vehicles Grids Smart Plug In in

    上传时间: 2020-06-07

    上传用户:shancjb

  • Plug In Electric Vehicles

    Plug in Electric Vehicles (PEVs) use energy storages usually in the form of battery banks that are designed to be recharged using utility grid power. One category of PEVs are Electric Vehicles (EVs) without an internal-Combustion (IC) engine where the energy stored in the battery bank is the only source of power to drive the vehicle. These are also referred as Battery Electric Vehicles (BEVs). The second category of PEVs, which is more commercialized than the EVs, is Plug in Hybrid Electric Vehicles (PHEVs) where the role of the energy storage is to supplement the power produced by the IC engine. 

    标签: Electric Vehicles Plug In

    上传时间: 2020-06-07

    上传用户:shancjb

  • Electric Vehicles in Smart Grids

    Plug in Electric Vehicles (PEVs) use energy storages usually in the form of battery banks that are designed to be recharged using utility grid power. One category of PEVs are Electric Vehicles (EVs) without an internal-Combustion (IC) engine where the energy stored in the battery bank is the only source of power to drive the vehicle. These are also referred to as Battery Electric Vehicles (BEVs). The second category of PEVs, which is more commercialized than the EVs, is the Plug in Hybrid Electric Vehicles (PHEVs) where the role of energy storage is to supplement the power produced by the IC engine. 

    标签: Electric Vehicles Smart Grids in

    上传时间: 2020-06-07

    上传用户:shancjb

  • MiniCore

    An Arduino core for the ATmega328, ATmega168, ATmega88, ATmega48 and ATmega8, all running a [custom version of Optiboot for increased functionality](#write-to-own-flash). This core requires at least Arduino IDE v1.6.2, where v1.8.5+ is recommended. <br/> **This core gives you two extra IO pins if you're using the internal oscillator!** PB6 and PB7 is mapped to [Arduino pin 20 and 21](#pinout).<br/> If you're into "generic" AVR programming, I'm happy to tell you that all relevant keywords are being highlighted by the IDE through a separate keywords file. Make sure to test the [example files](https://github.com/MCUdude/MiniCore/tree/master/avr/libraries/AVR_examples/examples) (File > Examples > AVR C code examples). Try writing a register name, <i>DDRB</i> for instance, and see for yourself!

    标签: MiniCore

    上传时间: 2021-02-22

    上传用户:

  • 基于TMS320F2812 光伏并网发电模拟装置PROTEL设计原理图+PCB+软件源码+WORD论

    基于TMS320F2812 光伏并网发电模拟装置PROTEL设计原理图+PCB+软件源码+WORD论文文档,硬件采用2层板设计,PROTEL99SE 设计的工程文件,包括完整的原理图和PCB文件,可以做为你的学习设计参考。 摘要:本文实现了一个基于TMS320F2812 DSP芯片的光伏并网发电模拟装置,采用直流稳压源和滑动变阻器来模拟光伏电池。通过TMS320F2812 DSP芯片ADC模块实时采样模拟电网电压的正弦参考信号、光伏电池输出电压、负载电压电流反馈信号等。经过数据处理后,用PWM模块产生实时的SPWM 波,控制MOSFET逆变全桥输出正弦波。本文用PI控制算法实现了输出信号对给定模拟电网电压的正弦参考信号的频率和相位跟踪,用恒定电压法实现了光伏电池最大功率点跟踪(MPPT),从而达到模拟并网的效果。另外本装置还实现了光伏电池输出欠压、负载过流保护功能以及光伏电池输出欠压、过流保护自恢复功能、声光报警功能、孤岛效应的检测、保护与自恢复功能。系统测试结果表明本设计完全满定设计要求。关键词:光伏并网,MPPT,DSP  Photovoltaic Grid-connected generation simulator Zhangyuxin,Tantiancheng,Xiewuyang(College of Electrical Engineering, Chongqing University)Abstract: This paper presents a photovoltaic grid-connected generation simulator which is based on TMS320F2812 DSP, with a DC voltage source and a variable resistor to simulate the characteristic of photovoltaic cells. We use the internal AD converter to real-time sampling the referenced grid voltage signal, outputting voltage of photovoltaic, feedback outputting voltage and current signal. The PWM module generates SVPWM according to the calculation of the real-time sampling data, to control the full MOSFET inverter bridge output sine wave. We realized that the output voltage of the simulator can track the frequency and phase of the referenced grid voltage with PI regulation, and the maximum photovoltaic power tracking with constant voltage regulation, thereby achieved the purpose of grid-connected simulation. Additionally, this device has the over-voltage and over-current protection, audible and visual alarm, islanding detecting and protection, and it can recover automatically. The testing shows that our design is feasible.Keywords: Photovoltaic Grid-connected,MPPT,DSP 目录引言 11. 方案论证 11.1. 总体介绍 11.2. 光伏电池模拟装置 11.3. DC-AC逆变桥 11.4. MOSFET驱动电路方案 21.5. 逆变电路的变频控制方案 22. 理论分析与计算 22.1. SPWM产生 22.1.1. 规则采样法 22.1.2. SPWM 脉冲的计算公式 32.1.3. SPWM 脉冲计算公式中的参数计算 32.1.4. TMS320F2812 DSP控制器的事件管理单元 42.1.5. 软件设计方法 62.2. MPPT的控制方法与参数计算 72.3. 同频、同相的控制方法和参数计算 8

    标签: tms320f2812 光伏 并网发电 模拟 protel pcb

    上传时间: 2021-11-02

    上传用户:ooaaooxx

  • 1 Seismic response control using electromagnetic

    This paper presents a new type of electromagnetic damper with rotating inertial mass that has been devel oped to control the vibrations of structures subjected to earthquakes. The electromagnetic inertial mass damper (EIMD) consists of a ball screw that converts axial oscillation of the rod end into rotational motion of the internal flflywheel and an electric generator that is turned by the rotation of the inner rod. The EIMD is able to generate a large inertial force created by the rotating flflywheel and a variable damping force devel oped by the electric generator. Device performance tests of reduced-scale and full-scale EIMDs were under taken to verify the basic characteristics of the damper and the validity of the derived theoretical formulae. Shaking table tests of a three-story structure with EIMDs and earthquake response analyses of a building with EIMDs were conducted to demonstrate the seismic response control performance of the EIMD. The EIMD is able to reduce story drifts as well as accelerations and surpasses conventional types of dampers in reducing acceleration responses.

    标签: electromagnetic response Seismic control using

    上传时间: 2021-11-04