虫虫首页|资源下载|资源专辑|精品软件
登录|注册

correspond

  • UNIX network programs the 1nd volume advancement to correspond the code

    UNIX network programs the 1nd volume advancement to correspond the code

    标签: advancement correspond the programs

    上传时间: 2016-02-17

    上传用户:xsnjzljj

  • DAC技术用语 (D/A Converters Defini

    Differential Nonlinearity: Ideally, any two adjacent digitalcodes correspond to output analog voltages that are exactlyone LSB apart. Differential non-linearity is a measure of theworst case deviation from the ideal 1 LSB step. For example,a DAC with a 1.5 LSB output change for a 1 LSB digital codechange exhibits 1⁄2 LSB differential non-linearity. Differentialnon-linearity may be expressed in fractional bits or as a percentageof full scale. A differential non-linearity greater than1 LSB will lead to a non-monotonic transfer function in aDAC.Gain Error (Full Scale Error): The difference between theoutput voltage (or current) with full scale input code and theideal voltage (or current) that should exist with a full scale inputcode.Gain Temperature Coefficient (Full Scale TemperatureCoefficient): Change in gain error divided by change in temperature.Usually expressed in parts per million per degreeCelsius (ppm/°C).Integral Nonlinearity (Linearity Error): Worst case deviationfrom the line between the endpoints (zero and full scale).Can be expressed as a percentage of full scale or in fractionof an LSB.LSB (Lease-Significant Bit): In a binary coded system thisis the bit that carries the smallest value or weight. Its value isthe full scale voltage (or current) divided by 2n, where n is theresolution of the converter.Monotonicity: A monotonic function has a slope whose signdoes not change. A monotonic DAC has an output thatchanges in the same direction (or remains constant) for eachincrease in the input code. the converse is true for decreasing codes.

    标签: Converters Defini DAC

    上传时间: 2013-10-29

    上传用户:stvnash

  • PCA9544A 4channel I2C multiple

    The PCA9544A provides 4 interrupt inputs, one for each channeland one open drain interrupt output. When an interrupt is generated byany device, it will be detected by the PCA9544A and the interruptoutput will be driven LOW. The channel need not be active fordetection of the interrupt. A bit is also set in the control byte.Bits 4 – 7 of the control byte correspond to channels 0 – 3 of thePCA9544A, respectively. Therefore, if an interrupt is generated byany device connected to channel 2, the state of the interrupt inputs isloaded into the control register when a read is accomplished.Likewise, an interrupt on any device connected to channel 0 wouldcause bit 4 of the control register to be set on the read. The mastercan then address the PCA9544A and read the contents of thecontrol byte to determine which channel contains the devicegenerating the interrupt. The master can then reconfigure thePCA9544A to select this channel, and locate the device generatingthe interrupt and clear it. The interrupt clears when the deviceoriginating the interrupt clears.

    标签: 4channel multiple 9544A 9544

    上传时间: 2014-12-27

    上传用户:潜水的三贡

  • MPC7400 Part Number Speci&THOR

    MPC7400 Part Number SpeciÞcationThis document describes part number speciÞc changes to recommended operating conditions and revised electrical speciÞcations,as applicable, from those described in the generalMPC7400 Hardware SpeciÞcations.SpeciÞcations provided in this Part Number SpeciÞcation supersede those in theMPC7400 Hardware SpeciÞcationsdated 9/99(order #: MPC7400EC/D) for these part numbers only; speciÞcations not addressed herein are unchanged. This document isfrequently updated, refer to the website at http://www.mot.com/SPS/PowerPC/ for the latest version.Note that headings and table numbers in this data sheet are not consecutively numbered. They are intended to correspond to theheading or table affected in the general hardware speciÞcation.

    标签: Number Speci 7400 Part

    上传时间: 2014-12-27

    上传用户:huyahui

  • MPC7400l零件号码规范说明

    This document describes part number speciÞc changes to recommended operating conditions and revised electrical speciÞcations,as applicable, from those described in the generalMPC7400 Hardware SpeciÞcations.SpeciÞcations provided in this Part Number SpeciÞcation supersede those in theMPC7400 Hardware SpeciÞcationsdated 9/99(order #: MPC7400EC/D) for these part numbers only; speciÞcations not addressed herein are unchanged. This document isfrequently updated, refer to the website at http://www.mot.com/SPS/PowerPC/ for the latest version.Note that headings and table numbers in this data sheet are not consecutively numbered. They are intended to correspond to theheading or table affected in the general hardware speciÞcation.Part numbers addressed in this document are listed in Table A. For more detailed ordering information see Table B.

    标签: 7400l 7400 MPC 零件

    上传时间: 2013-11-18

    上传用户:qiaoyue

  • The JICQ is the bureau area which JAVA writes according to "Customer s Machine/Server"(C/S) mode mes

    The JICQ is the bureau area which JAVA writes according to "Customer s Machine/Server"(C/S) mode message solid hour correspond by letter tool system, the system adopted the SQL Server2000 of Microsoft company as a backstage database, the system passes a JDBC interview database. The system is divided into the server procedure and customer s procedure two parts, server and customer adoption "Transmission Control Protocol"(TCP), connect a word (Socket) conjunction through a set, the adoption "User Datagram Protocol "(UDP) of the customer s, pass a data report a set to connect a word (DatagramSocket) establishment a conjunction. The system has customer registration, customer to register, increase good friend, delete good friend and send out and receive news etc. function.

    标签: according Customer Machine Server

    上传时间: 2014-01-04

    上传用户:jyycc

  • function y_cum = cum2x (x,y, maxlag, nsamp, overlap, flag) %CUM2X Cross-covariance % y_cum = cum2x

    function y_cum = cum2x (x,y, maxlag, nsamp, overlap, flag) %CUM2X Cross-covariance % y_cum = cum2x (x,y,maxlag, samp_seg, overlap, flag) % x,y - data vectors/matrices with identical dimensions % if x,y are matrices, rather than vectors, columns are % assumed to correspond to independent realizations, % overlap is set to 0, and samp_seg to the row dimension. % maxlag - maximum lag to be computed [default = 0] % samp_seg - samples per segment [default = data_length] % overlap - percentage overlap of segments [default = 0] % overlap is clipped to the allowed range of [0,99].

    标签: cum2x y_cum Cross-covariance function

    上传时间: 2015-09-08

    上传用户:xieguodong1234

  • When the record within form of the mouse list shot row, in the basic data area manifestation corresp

    When the record within form of the mouse list shot row, in the basic data area manifestation correspond a data

    标签: the manifestation corresp record

    上传时间: 2013-12-18

    上传用户:上善若水