As logic systems get larger and more complex, theirsupply current requirements continue to rise. Systemsrequiring 100A are fairly common. A high current Powersupply to meet such requirements usually requires parallelingseveral Power regulators to alleviate the thermalstress on the individual Power components. A Powersupply designer is left with the choice of how to drive theseparalleled regulators: brute-force single-phase or smartPolyPhaseTM.
上传时间: 2013-10-08
上传用户:zhqzal1014
This collection of circuits was worked out between June1991 and July of 1994. Most were designed at customerrequest or are derivatives of such efforts. All representsubstantial effort and, as such, are disseminated here forwider study and (hopefully) use.1 The examples areroughly arranged in categories including Power conversion,transducer signal conditioning, amplifiers and signalgenerators. As always, reader comment and questionsconcerning variants of the circuits shown may be addresseddirectly to the author.
上传时间: 2013-11-15
上传用户:凌云御清风
Notebook and palmtop systems need a multiplicity ofregulated voltages developed from a single battery. Smallsize, light weight, and high efficiency are mandatory forcompetitive solutions in this area. Small increases inefficiency extend battery life, making the final productmuch more usable with no increase in weight. Additionally,high efficiency minimizes the heat sinks needed onthe Power regulating components, further reducing systemweight and size.
上传时间: 2013-11-11
上传用户:大三三
In an increasing trend, telecommunications, networking,audio and instrumentation require low noise Power supplies.In particular, there is interest in low noise, lowdropout linear regulators (LDO). These components Powernoise-sensitive circuitry, circuitry that contains noisesensitiveelements or both. Additionally, to conserve Power,particularly in battery driven apparatus such as cellulartelephones, the regulators must operate with low input-tooutputvoltages.1 Devices presently becoming availablemeet these requirements (see separate section, “A Familyof 20mVRMS Noise, Low Dropout Regulators”).
上传时间: 2013-10-30
上传用户:yeling1919
The LTM4601 DC/DC μModule regulator is a completehigh Power density stepdown regulator for up to 12Acontinuous (14A peak) loads. The device is housed ina small 15mm ¥ 15mm ¥ 2.8mm LGA surface mountpackage, thus the large Power dissipation is a challengein some applications. This thermal application note willprovide guidelines for using the μModule regulator inambient environments with or without air fl ow. Loadcurrent derating curves are provided for several inputvoltages and output voltages versus ambient temperatureand air fl ow.
上传时间: 2013-10-19
上传用户:bakdesec
The LTM8020, LTM8021, LTM8022 and LTM8023 μModule®regulators are complete easy-to-use encapsulated stepdownDC/DC regulators intended to take the pain and aggravationout of implementing a switching Power supplyonto a system board. With a μModule regulator, you onlyneed an input cap, output cap and one or two resistorsto complete the design. As one might imagine, this highlevel of integration greatly simplifi es the task of printedcircuit board design, reducing the effort to four categories:component footprint generation, component placement,routing the nets, and thermal vias.
上传时间: 2014-01-18
上传用户:laomv123
Providing Power for the Pentium® microprocessor family isnot a trivial task by any means. In an effort to simplify thistask we have developed a new switching regulator controlcircuit and a new linear regulator to address the needs ofthese processors. Considerable time has been spent developingan optimized decoupling network. Here are severalcircuits using the new LTC®1266 synchronous buck regulatorcontrol chip and the LT®1584 linear regulator toprovide Power for Pentium processors and Pentium VREprocessors. The Pentium processor has a supply requirementof 3.3V ±5%. The Pentium VRE processor requires3.500V ±100mV.
上传时间: 2013-11-01
上传用户:名爵少年
Portable, battery-Powered operation of electronic apparatushas become increasingly desirable. Medical, remotedata acquisition, Power monitoring and other applicationsare good candidates for batteryoperation. In some circumstances,due to space, Power or reliability considerations,it is preferable to operate the circuitry from a single 1.5Vcell. Unfortunately, a 1.5V supply eliminates almost alllinear ICs as design candidates. In fact, the LM10 opamp-reference and the LT®1017/LT1018 comparators arethe only IC gain blocks fully specifi ed for 1.5V operation.Further complications are presented by the 600mV dropof silicon transistors and diodes. This limitation consumesa substantial portion of available supply range, makingcircuit design diffi cult. Additionally, any circuit designedfor 1.5V operation mustfunction at end-of-life batteryvoltage, typically 1.3V. (See Box Section, “Componentsfor 1.5V Operation.”)
标签: Circuitry Operation Single Cell
上传时间: 2013-10-30
上传用户:hz07104032
In predominantly digital systems it is often necessaryto include linear circuit functions. Traditionally, separatePower supplies have been used to run the linear components(see Box, “Linear Power Supplies—Past, Present,and Future”).
标签: Designing Operation Circuits Linear
上传时间: 2013-11-04
上传用户:sdq_123
为了改变目前电网现场作业管理的变电巡检、变电检修试验、输电线路巡检检修等管理系统各自独立运行,信息不能共享,功能、效率受限,建设和维护成本高的现状,提出了采用B/S+C/S构架模式,将各现场作业管理模块和生产MIS(管理系统)集成为一体的现场作业管理系统的设计方案,做到各子系统和生产MIS软硬资源共享,做到同一数据唯一入口、一处录入多处使用。各子系统设备人员等基础信息来源于生产管理系统,各子系统又是生产管理系统的作业数据、缺陷信息的重要来源。经过研究试用成功和推广应用,目前该系统已在江西电网220 kV及以上变电站全面应用。 Abstract: In order to improve the status that the substation field inspection system, substation equipments maintenance and testing system, Power-line inspection and maintenance system are running independent with each other. They can?蒺t share the resource information which accordingly constrains their functions and efficiency, and their construction and maintenance costs are high. This paper introduces a field standardized work management system based on B/S+C/S mode, integrating all field work management systems based on MIS and share the equipments and employee?蒺s data of MIS,the field work data of the sub systems are the source information of MIS, by which the same single data resouce with one-time input can be utilized in multiple places. After the research and testing, this system is triumphantly using in all 220kV and above substations in Jiangxi grid.
上传时间: 2013-11-15
上传用户:han_zh