📄 lcd.rpt
字号:
Name Pt Pt Pt Pt Mode # Type Use
data<5>_BUFR 15 10<- 0 0 FB2_1 STD 142 I/O (b)
(unused) 0 0 /\5 0 FB2_2 143 GSR/I/O (b)
(unused) 0 0 0 5 FB2_3 (b)
(unused) 0 0 0 5 FB2_4 4 I/O
(unused) 0 0 0 5 FB2_5 2 GTS/I/O
(unused) 0 0 0 5 FB2_6 3 GTS/I/O
(unused) 0 0 0 5 FB2_7 (b)
clkdiv<0> 2 0 0 3 FB2_8 STD 5 GTS/I/O (b)
flag 3 0 0 2 FB2_9 STD 6 GTS/I/O (b)
clkdiv<4> 3 0 0 2 FB2_10 STD 7 I/O (b)
clkdiv<3> 3 0 0 2 FB2_11 STD 9 I/O (b)
clkdiv<2> 3 0 0 2 FB2_12 STD 10 I/O (b)
clkdiv<1> 3 0 0 2 FB2_13 STD 12 I/O (b)
state_FFT3 4 0 0 1 FB2_14 STD 11 I/O (b)
div_counter<3> 5 0 0 0 FB2_15 STD 13 I/O (b)
div_counter<2> 5 0 0 0 FB2_16 STD 14 I/O (b)
div_counter<1> 5 0 0 0 FB2_17 STD 15 I/O (b)
(unused) 0 0 \/5 0 FB2_18 (b) (b)
Signals Used by Logic in Function Block
1: Reset 10: clkdiv<2> 19: div_counter<0>
2: clk 11: clkdiv<3> 20: div_counter<1>
3: clkdiv<0> 12: counter<0> 21: div_counter<2>
4: clkdiv<1> 13: counter<1> 22: div_counter<3>
5: clkdiv<20> 14: counter<2> 23: flag
6: clkdiv<21> 15: counter<3> 24: state_FFT1
7: clkdiv<22> 16: counter<4> 25: state_FFT2
8: clkdiv<23> 17: counter<5> 26: state_FFT3
9: clkdiv<24> 18: counter<6>
Signal 1 2 3 4 Signals FB
Name 0----+----0----+----0----+----0----+----0 Used Inputs
data<5>_BUFR ...........XXXXXXX.....XXX.............. 10 10
clkdiv<0> XX...................................... 2 2
flag X...XXXXX.............XXXX.............. 10 10
clkdiv<4> XXXX.....XX............................. 6 6
clkdiv<3> XXXX.....X.............................. 5 5
clkdiv<2> XXXX.................................... 4 4
clkdiv<1> XXX..................................... 3 3
state_FFT3 X...XXXXX.............XXXX.............. 10 10
div_counter<3> X...XXXXX.........XXXXXXXX.............. 14 14
div_counter<2> X...XXXXX.........XXX.XXXX.............. 13 13
div_counter<1> X...XXXXX.........XX..XXXX.............. 12 12
0----+----1----+----2----+----3----+----4
0 0 0 0
Legend:
Total Pt - Total product terms used by the macrocell signal
Imp Pt - Product terms imported from other macrocells
Exp Pt - Product terms exported to other macrocells
in direction shown
Unused Pt - Unused local product terms remaining in macrocell
Loc - Location where logic was mapped in device
Pwr Mode - Macrocell power mode
Pin Type/Use - I - Input GCK - Global Clock
O - Output GTS - Global Output Enable
(b) - Buried macrocell GSR - Global Set/Reset
X(@) - Signal used as input (wire-AND input) to the macrocell logic.
The number of Signals Used may exceed the number of FB Inputs Used due
to wire-ANDing in the switch matrix.
*********************************** FB3 ***********************************
Number of function block inputs used/remaining: 8/46
Number of signals used by logic mapping into function block: 8
Signal Total Imp Exp Unused Loc Pwr Pin Pin Pin
Name Pt Pt Pt Pt Mode # Type Use
(unused) 0 0 0 5 FB3_1 39 I/O
(unused) 0 0 0 5 FB3_2 32 GCK/I/O
(unused) 0 0 0 5 FB3_3 41 I/O
(unused) 0 0 0 5 FB3_4 44 I/O
(unused) 0 0 0 5 FB3_5 33 I/O
(unused) 0 0 0 5 FB3_6 34 I/O
(unused) 0 0 0 5 FB3_7 46 I/O
(unused) 0 0 0 5 FB3_8 38 GCK/I/O
(unused) 0 0 0 5 FB3_9 40 I/O
(unused) 0 0 0 5 FB3_10 48 I/O
(unused) 0 0 0 5 FB3_11 43 I/O
(unused) 0 0 0 5 FB3_12 45 I/O
(unused) 0 0 0 5 FB3_13 (b)
(unused) 0 0 0 5 FB3_14 49 I/O
(unused) 0 0 0 5 FB3_15 50 I/O
(unused) 0 0 0 5 FB3_16 (b)
clkdiv<6> 3 0 0 2 FB3_17 STD 51 I/O (b)
clkdiv<5> 3 0 0 2 FB3_18 STD (b) (b)
Signals Used by Logic in Function Block
1: Reset 4: clkdiv<1> 7: clkdiv<4>
2: clk 5: clkdiv<2> 8: clkdiv<5>
3: clkdiv<0> 6: clkdiv<3>
Signal 1 2 3 4 Signals FB
Name 0----+----0----+----0----+----0----+----0 Used Inputs
clkdiv<6> XXXXXXXX................................ 8 8
clkdiv<5> XXXXXXX................................. 7 7
0----+----1----+----2----+----3----+----4
0 0 0 0
Legend:
Total Pt - Total product terms used by the macrocell signal
Imp Pt - Product terms imported from other macrocells
Exp Pt - Product terms exported to other macrocells
in direction shown
Unused Pt - Unused local product terms remaining in macrocell
Loc - Location where logic was mapped in device
Pwr Mode - Macrocell power mode
Pin Type/Use - I - Input GCK - Global Clock
O - Output GTS - Global Output Enable
(b) - Buried macrocell GSR - Global Set/Reset
X(@) - Signal used as input (wire-AND input) to the macrocell logic.
The number of Signals Used may exceed the number of FB Inputs Used due
to wire-ANDing in the switch matrix.
*********************************** FB4 ***********************************
Number of function block inputs used/remaining: 0/54
Number of signals used by logic mapping into function block: 0
Signal Total Imp Exp Unused Loc Pwr Pin Pin Pin
Name Pt Pt Pt Pt Mode # Type Use
(unused) 0 0 0 5 FB4_1 118 I/O
(unused) 0 0 0 5 FB4_2 126 I/O
(unused) 0 0 0 5 FB4_3 133 I/O
(unused) 0 0 0 5 FB4_4 (b)
(unused) 0 0 0 5 FB4_5 128 I/O I
(unused) 0 0 0 5 FB4_6 129 I/O
(unused) 0 0 0 5 FB4_7 (b)
(unused) 0 0 0 5 FB4_8 130 I/O
(unused) 0 0 0 5 FB4_9 131 I/O
(unused) 0 0 0 5 FB4_10 135 I/O
(unused) 0 0 0 5 FB4_11 132 I/O
(unused) 0 0 0 5 FB4_12 134 I/O
(unused) 0 0 0 5 FB4_13 137 I/O
(unused) 0 0 0 5 FB4_14 136 I/O
(unused) 0 0 0 5 FB4_15 138 I/O
(unused) 0 0 0 5 FB4_16 139 I/O
(unused) 0 0 0 5 FB4_17 140 I/O
(unused) 0 0 0 5 FB4_18 (b)
Legend:
Total Pt - Total product terms used by the macrocell signal
Imp Pt - Product terms imported from other macrocells
Exp Pt - Product terms exported to other macrocells
in direction shown
Unused Pt - Unused local product terms remaining in macrocell
Loc - Location where logic was mapped in device
Pwr Mode - Macrocell power mode
Pin Type/Use - I - Input GCK - Global Clock
O - Output GTS - Global Output Enable
(b) - Buried macrocell GSR - Global Set/Reset
X(@) - Signal used as input (wire-AND input) to the macrocell logic.
The number of Signals Used may exceed the number of FB Inputs Used due
to wire-ANDing in the switch matrix.
*********************************** FB5 ***********************************
Number of function block inputs used/remaining: 25/29
Number of signals used by logic mapping into function block: 25
Signal Total Imp Exp Unused Loc Pwr Pin Pin Pin
Name Pt Pt Pt Pt Mode # Type Use
counter<6> 4 0 0 1 FB5_1 STD (b) (b)
counter<5> 4 0 0 1 FB5_2 STD 52 I/O (b)
counter<4> 5 0 0 0 FB5_3 STD 59 I/O (b)
counter<3> 5 0 0 0 FB5_4 STD (b) (b)
counter<2> 5 0 0 0 FB5_5 STD 53 I/O (b)
counter<1> 5 0 0 0 FB5_6 STD 54 I/O (b)
data<5> 2 0 0 3 FB5_7 STD 66 I/O O
lcd_rw 1 0 0 4 FB5_8 STD 56 I/O O
lcd_rs 1 0 \/1 3 FB5_9 STD 57 I/O O
counter<0> 6 1<- 0 0 FB5_10 STD 68 I/O (b)
data<7> 2 0 \/1 2 FB5_11 STD 58 I/O O
state_FFT2 7 2<- 0 0 FB5_12 STD 60 I/O (b)
data<1> 2 0 /\1 2 FB5_13 STD 70 I/O O
data<6> 2 0 0 3 FB5_14 STD 61 I/O O
data<4> 2 0 \/3 0 FB5_15 STD 64 I/O O
state_FFT1 7 3<- \/1 0 FB5_16 STD (b) (b)
data<3> 11 6<- 0 0 FB5_17 STD 69 I/O O
(unused) 0 0 /\5 0 FB5_18 (b) (b)
Signals Used by Logic in Function Block
1: Reset 10: counter<3> 18: div_counter<0>
2: clkdiv<20> 11: counter<4> 19: div_counter<1>
3: clkdiv<21> 12: counter<5> 20: div_counter<2>
4: clkdiv<22> 13: counter<6> 21: div_counter<3>
5: clkdiv<23> 14: data<1>_BUFR 22: flag
6: clkdiv<24> 15: data<4>_BUFR 23: state_FFT1
7: counter<0> 16: data<5>_BUFR 24: state_FFT2
8: counter<1> 17: data<6>_BUFR 25: state_FFT3
9: counter<2>
Signal 1 2 3 4 Signals FB
Name 0----+----0----+----0----+----0----+----0 Used Inputs
counter<6> XXXXXXXXXXXXX........XXXX............... 17 17
counter<5> XXXXXXXXXXXXX........XXXX............... 17 17
counter<4> XXXXXXXXXXXXX........XXXX............... 17 17
counter<3> XXXXXXXXXXXXX........XXXX............... 17 17
counter<2> XXXXXXXXX.XXX........XXXX............... 16 16
counter<1> XXXXXXXX..XXX........XXXX............... 15 15
data<5> ...............X......XXX............... 4 4
lcd_rw ......................XXX............... 3 3
lcd_rs ......................XXX............... 3 3
counter<0> XXXXXXXXXXXXX........XXXX............... 17 17
data<7> ......................XXX............... 3 3
state_FFT2 XXXXXXXXXXXXX.........XXX............... 16 16
data<1> .............X........XXX............... 4 4
data<6> ................X.....XXX............... 4 4
data<4> ..............X.......XXX............... 4 4
state_FFT1 XXXXXXXXXXXXX....XXXXXXXX............... 21 21
data<3> ......XXXXXXX.........XXX............... 10 10
0----+----1----+----2----+----3----+----4
0 0 0 0
Legend:
Total Pt - Total product terms used by the macrocell signal
Imp Pt - Product terms imported from other macrocells
Exp Pt - Product terms exported to other macrocells
in direction shown
Unused Pt - Unused local product terms remaining in macrocell
Loc - Location where logic was mapped in device
Pwr Mode - Macrocell power mode
Pin Type/Use - I - Input GCK - Global Clock
O - Output GTS - Global Output Enable
(b) - Buried macrocell GSR - Global Set/Reset
X(@) - Signal used as input (wire-AND input) to the macrocell logic.
The number of Signals Used may exceed the number of FB Inputs Used due
to wire-ANDing in the switch matrix.
*********************************** FB6 ***********************************
Number of function block inputs used/remaining: 0/54
Number of signals used by logic mapping into function block: 0
Signal Total Imp Exp Unused Loc Pwr Pin Pin Pin
Name Pt Pt Pt Pt Mode # Type Use
(unused) 0 0 0 5 FB6_1 (b)
(unused) 0 0 0 5 FB6_2 106 I/O
(unused) 0 0 0 5 FB6_3 (b)
⌨️ 快捷键说明
复制代码
Ctrl + C
搜索代码
Ctrl + F
全屏模式
F11
切换主题
Ctrl + Shift + D
显示快捷键
?
增大字号
Ctrl + =
减小字号
Ctrl + -