⭐ 欢迎来到虫虫下载站! | 📦 资源下载 📁 资源专辑 ℹ️ 关于我们
⭐ 虫虫下载站

📄 ddr2_model_parameters.vh

📁 DDR2 SDRAM仿真模型
💻 VH
📖 第 1 页 / 共 5 页
字号:
/******************************************************************************************   Disclaimer   This software code and all associated documentation, comments or other*  of Warranty:  information (collectively "Software") is provided "AS IS" without*                warranty of any kind. MICRON TECHNOLOGY, INC. ("MTI") EXPRESSLY*                DISCLAIMS ALL WARRANTIES EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED*                TO, NONINFRINGEMENT OF THIRD PARTY RIGHTS, AND ANY IMPLIED WARRANTIES*                OF MERCHANTABILITY OR FITNESS FOR ANY PARTICULAR PURPOSE. MTI DOES NOT*                WARRANT THAT THE SOFTWARE WILL MEET YOUR REQUIREMENTS, OR THAT THE*                OPERATION OF THE SOFTWARE WILL BE UNINTERRUPTED OR ERROR-FREE.*                FURTHERMORE, MTI DOES NOT MAKE ANY REPRESENTATIONS REGARDING THE USE OR*                THE RESULTS OF THE USE OF THE SOFTWARE IN TERMS OF ITS CORRECTNESS,*                ACCURACY, RELIABILITY, OR OTHERWISE. THE ENTIRE RISK ARISING OUT OF USE*                OR PERFORMANCE OF THE SOFTWARE REMAINS WITH YOU. IN NO EVENT SHALL MTI,*                ITS AFFILIATED COMPANIES OR THEIR SUPPLIERS BE LIABLE FOR ANY DIRECT,*                INDIRECT, CONSEQUENTIAL, INCIDENTAL, OR SPECIAL DAMAGES (INCLUDING,*                WITHOUT LIMITATION, DAMAGES FOR LOSS OF PROFITS, BUSINESS INTERRUPTION,*                OR LOSS OF INFORMATION) ARISING OUT OF YOUR USE OF OR INABILITY TO USE*                THE SOFTWARE, EVEN IF MTI HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH*                DAMAGES. Because some jurisdictions prohibit the exclusion or*                limitation of liability for consequential or incidental damages, the*                above limitation may not apply to you.**                Copyright 2003 Micron Technology, Inc. All rights reserved.*****************************************************************************************/    // Timing parameters based on Speed Grade                                          // SYMBOL UNITS DESCRIPTION                                          // ------ ----- -----------`ifdef x256Mb`ifdef sg25E    parameter TCK_MIN          =    2500; // tCK    ps    Minimum Clock Cycle Time    parameter TJIT_PER         =     100; // tJIT(per)  ps Period JItter    parameter TJIT_DUTY        =     100; // tJIT(duty) ps Half Period Jitter    parameter TJIT_CC          =     200; // tJIT(cc)   ps Cycle to Cycle jitter    parameter TERR_2PER        =     150; // tERR(nper) ps Accumulated Error (2-cycle)    parameter TERR_3PER        =     175; // tERR(nper) ps Accumulated Error (3-cycle)    parameter TERR_4PER        =     200; // tERR(nper) ps Accumulated Error (4-cycle)    parameter TERR_5PER        =     200; // tERR(nper) ps Accumulated Error (5-cycle)    parameter TERR_N1PER       =     300; // tERR(nper) ps Accumulated Error (6-10-cycle)    parameter TERR_N2PER       =     450; // tERR(nper) ps Accumulated Error (11-50-cycle)    parameter TQHS             =     300; // tQHS   ps    Data hold skew factor    parameter TAC              =     400; // tAC    ps    DQ output access time from CK/CK#    parameter TDS              =      50; // tDS    ps    DQ and DM input setup time relative to DQS    parameter TDH              =     125; // tDH    ps    DQ and DM input hold time relative to DQS    parameter TDQSCK           =     350; // tDQSCK ps    DQS output access time from CK/CK#    parameter TDQSQ            =     200; // tDQSQ  ps    DQS-DQ skew, DQS to last DQ valid, per group, per access    parameter TWPRE            =    0.35; // tWPRE  tCK   DQS Write Preamble    parameter TIS              =     200; // tIS    ps    Input Setup Time    parameter TIH              =     275; // tIH    ps    Input Hold Time    parameter TRC              =   55000; // tRC    ps    Active to Active/Auto Refresh command time    parameter TRCD             =   12000; // tRCD   ps    Active to Read/Write command time    parameter TWTR             =    7500; // tWTR   ps    Write to Read command delay    parameter TRP              =   12500; // tRP    ps    Precharge command period    parameter TXARDS           =       8; // tXARDS tCK   Exit low power active power down to a read command    parameter CL_TIME          =   12500; // CL     ps    Minimum CAS Latency`else `ifdef sg3E    parameter TCK_MIN          =    3000; // tCK    ps    Minimum Clock Cycle Time    parameter TJIT_PER         =     125; // tJIT(per)  ps Period JItter    parameter TJIT_DUTY        =     125; // tJIT(duty) ps Half Period Jitter    parameter TJIT_CC          =     250; // tJIT(cc)   ps Cycle to Cycle jitter    parameter TERR_2PER        =     175; // tERR(nper) ps Accumulated Error (2-cycle)    parameter TERR_3PER        =     225; // tERR(nper) ps Accumulated Error (3-cycle)    parameter TERR_4PER        =     250; // tERR(nper) ps Accumulated Error (4-cycle)    parameter TERR_5PER        =     250; // tERR(nper) ps Accumulated Error (5-cycle)    parameter TERR_N1PER       =     350; // tERR(nper) ps Accumulated Error (6-10-cycle)    parameter TERR_N2PER       =     450; // tERR(nper) ps Accumulated Error (11-50-cycle)    parameter TQHS             =     340; // tQHS   ps    Data hold skew factor    parameter TAC              =     450; // tAC    ps    DQ output access time from CK/CK#    parameter TDS              =     100; // tDS    ps    DQ and DM input setup time relative to DQS    parameter TDH              =     175; // tDH    ps    DQ and DM input hold time relative to DQS    parameter TDQSCK           =     400; // tDQSCK ps    DQS output access time from CK/CK#    parameter TDQSQ            =     240; // tDQSQ  ps    DQS-DQ skew, DQS to last DQ valid, per group, per access    parameter TWPRE            =    0.35; // tWPRE  tCK   DQS Write Preamble    parameter TIS              =     200; // tIS    ps    Input Setup Time    parameter TIH              =     275; // tIH    ps    Input Hold Time    parameter TRC              =   54000; // tRC    ps    Active to Active/Auto Refresh command time    parameter TRCD             =   12000; // tRCD   ps    Active to Read/Write command time    parameter TWTR             =    7500; // tWTR   ps    Write to Read command delay    parameter TRP              =   12000; // tRP    ps    Precharge command period    parameter TXARDS           =       7; // tXARDS tCK   Exit low power active power down to a read command    parameter CL_TIME          =   12000; // CL     ps    Minimum CAS Latency`else `ifdef sg3    parameter TCK_MIN          =    3000; // tCK    ps    Minimum Clock Cycle Time    parameter TJIT_PER         =     125; // tJIT(per)  ps Period JItter    parameter TJIT_DUTY        =     125; // tJIT(duty) ps Half Period Jitter    parameter TJIT_CC          =     250; // tJIT(cc)   ps Cycle to Cycle jitter    parameter TERR_2PER        =     175; // tERR(nper) ps Accumulated Error (2-cycle)    parameter TERR_3PER        =     225; // tERR(nper) ps Accumulated Error (3-cycle)    parameter TERR_4PER        =     250; // tERR(nper) ps Accumulated Error (4-cycle)    parameter TERR_5PER        =     250; // tERR(nper) ps Accumulated Error (5-cycle)    parameter TERR_N1PER       =     350; // tERR(nper) ps Accumulated Error (6-10-cycle)    parameter TERR_N2PER       =     450; // tERR(nper) ps Accumulated Error (11-50-cycle)    parameter TQHS             =     340; // tQHS   ps    Data hold skew factor    parameter TAC              =     450; // tAC    ps    DQ output access time from CK/CK#    parameter TDS              =     100; // tDS    ps    DQ and DM input setup time relative to DQS    parameter TDH              =     175; // tDH    ps    DQ and DM input hold time relative to DQS    parameter TDQSCK           =     400; // tDQSCK ps    DQS output access time from CK/CK#    parameter TDQSQ            =     240; // tDQSQ  ps    DQS-DQ skew, DQS to last DQ valid, per group, per access    parameter TWPRE            =    0.35; // tWPRE  tCK   DQS Write Preamble    parameter TIS              =     200; // tIS    ps    Input Setup Time    parameter TIH              =     275; // tIH    ps    Input Hold Time    parameter TRC              =   55000; // tRC    ps    Active to Active/Auto Refresh command time    parameter TRCD             =   15000; // tRCD   ps    Active to Read/Write command time    parameter TWTR             =    7500; // tWTR   ps    Write to Read command delay    parameter TRP              =   15000; // tRP    ps    Precharge command period    parameter TXARDS           =       7; // tXARDS tCK   Exit low power active power down to a read command    parameter CL_TIME          =   15000; // CL     ps    Minimum CAS Latency`else `ifdef sg37E    parameter TCK_MIN          =    3750; // tCK    ps    Minimum Clock Cycle Time    parameter TJIT_PER         =     125; // tJIT(per)  ps Period JItter    parameter TJIT_DUTY        =     125; // tJIT(duty) ps Half Period Jitter    parameter TJIT_CC          =     250; // tJIT(cc)   ps Cycle to Cycle jitter    parameter TERR_2PER        =     175; // tERR(nper) ps Accumulated Error (2-cycle)    parameter TERR_3PER        =     225; // tERR(nper) ps Accumulated Error (3-cycle)    parameter TERR_4PER        =     250; // tERR(nper) ps Accumulated Error (4-cycle)    parameter TERR_5PER        =     250; // tERR(nper) ps Accumulated Error (5-cycle)    parameter TERR_N1PER       =     350; // tERR(nper) ps Accumulated Error (6-10-cycle)    parameter TERR_N2PER       =     450; // tERR(nper) ps Accumulated Error (11-50-cycle)    parameter TQHS             =     400; // tQHS   ps    Data hold skew factor    parameter TAC              =     500; // tAC    ps    DQ output access time from CK/CK#    parameter TDS              =     100; // tDS    ps    DQ and DM input setup time relative to DQS    parameter TDH              =     225; // tDH    ps    DQ and DM input hold time relative to DQS    parameter TDQSCK           =     450; // tDQSCK ps    DQS output access time from CK/CK#    parameter TDQSQ            =     300; // tDQSQ  ps    DQS-DQ skew, DQS to last DQ valid, per group, per access    parameter TWPRE            =    0.25; // tWPRE  tCK   DQS Write Preamble    parameter TIS              =     250; // tIS    ps    Input Setup Time    parameter TIH              =     375; // tIH    ps    Input Hold Time    parameter TRC              =   55000; // tRC    ps    Active to Active/Auto Refresh command time    parameter TRCD             =   15000; // tRCD   ps    Active to Read/Write command time    parameter TWTR             =    7500; // tWTR   ps    Write to Read command delay    parameter TRP              =   15000; // tRP    ps    Precharge command period    parameter TXARDS           =       6; // tXARDS tCK   Exit low power active power down to a read command    parameter CL_TIME          =   15000; // CL     ps    Minimum CAS Latency`else `define sg5E    parameter TCK_MIN          =    5000; // tCK    ps    Minimum Clock Cycle Time    parameter TJIT_PER         =     125; // tJIT(per)  ps Period JItter    parameter TJIT_DUTY        =     150; // tJIT(duty) ps Half Period Jitter    parameter TJIT_CC          =     250; // tJIT(cc)   ps Cycle to Cycle jitter    parameter TERR_2PER        =     175; // tERR(nper) ps Accumulated Error (2-cycle)    parameter TERR_3PER        =     225; // tERR(nper) ps Accumulated Error (3-cycle)    parameter TERR_4PER        =     250; // tERR(nper) ps Accumulated Error (4-cycle)    parameter TERR_5PER        =     250; // tERR(nper) ps Accumulated Error (5-cycle)    parameter TERR_N1PER       =     350; // tERR(nper) ps Accumulated Error (6-10-cycle)    parameter TERR_N2PER       =     450; // tERR(nper) ps Accumulated Error (11-50-cycle)    parameter TQHS             =     450; // tQHS   ps    Data hold skew factor    parameter TAC              =     600; // tAC    ps    DQ output access time from CK/CK#    parameter TDS              =     150; // tDS    ps    DQ and DM input setup time relative to DQS    parameter TDH              =     275; // tDH    ps    DQ and DM input hold time relative to DQS    parameter TDQSCK           =     500; // tDQSCK ps    DQS output access time from CK/CK#    parameter TDQSQ            =     350; // tDQSQ  ps    DQS-DQ skew, DQS to last DQ valid, per group, per access    parameter TWPRE            =    0.25; // tWPRE  tCK   DQS Write Preamble    parameter TIS              =     350; // tIS    ps    Input Setup Time    parameter TIH              =     475; // tIH    ps    Input Hold Time    parameter TRC              =   55000; // tRC    ps    Active to Active/Auto Refresh command time    parameter TRCD             =   15000; // tRCD   ps    Active to Read/Write command time    parameter TWTR             =   10000; // tWTR   ps    Write to Read command delay    parameter TRP              =   15000; // tRP    ps    Precharge command period    parameter TXARDS           =       6; // tXARDS tCK   Exit low power active power down to a read command    parameter CL_TIME          =   15000; // CL     ps    Minimum CAS Latency`endif `endif `endif `endif

⌨️ 快捷键说明

复制代码 Ctrl + C
搜索代码 Ctrl + F
全屏模式 F11
切换主题 Ctrl + Shift + D
显示快捷键 ?
增大字号 Ctrl + =
减小字号 Ctrl + -