📄 k4s280832c.ftm
字号:
(INSTANCE %LABEL%/TRP) (DELAY (ABSOLUTE ( DEVICE (20) ) ) )) (CELL (CELLTYPE "VITALbuf" ) (INSTANCE %LABEL%/TWR) (DELAY (ABSOLUTE ( DEVICE (15) ) ) )</TIMING></FMFTIME><FMFTIME>uPD45128841G5-A80-9JF<SOURCE>NEC Data Sheet M12650EJAV0DS00 January 2000</SOURCE><COMMENT> The values listed are for VCC=3V to 3.6V, CL=50pF, Ta=0 to +70 Celsius</COMMENT><COMMENT> Typical values are derived</COMMENT><TIMING> (DELAY (ABSOLUTE (IOPATH CLK DQ2 (3.0:5.0:7.0) (3.0:5.0:7.0) (3.0:5.0:6.0) (0.0:5.0:6.0) (3.0:5.0:6.0) (0.0:5.0:6.0)) (IOPATH CLK DQ3 (3.0:4.0:6.0) (3.0:4.0:6.0) (3.0:5.0:6.0) (0.0:5.0:6.0) (3.0:5.0:6.0) (0.0:5.0:6.0)) )) (TIMINGCHECK (HOLD DQ0 CLK (1.0)) (SETUP DQ0 CLK (2.0)) (WIDTH (posedge CLK) (3.0)) (WIDTH (negedge CLK) (3.0)) (PERIOD (posedge CLK) (13)) )) (CELL (CELLTYPE "VITALbuf" ) (INSTANCE %LABEL%/TRAS) (DELAY (ABSOLUTE ( DEVICE (50) (120000) ) ) ) ) (CELL (CELLTYPE "VITALbuf" ) (INSTANCE %LABEL%/TRC) (DELAY (ABSOLUTE ( DEVICE (70) ) ) )) (CELL (CELLTYPE "VITALbuf" ) (INSTANCE %LABEL%/TRCAR) (DELAY (ABSOLUTE ( DEVICE (70) ) ) )) (CELL (CELLTYPE "VITALbuf" ) (INSTANCE %LABEL%/TRCD) (DELAY (ABSOLUTE ( DEVICE (20) ) ) )) (CELL (CELLTYPE "VITALbuf" ) (INSTANCE %LABEL%/REF) (DELAY (ABSOLUTE ( DEVICE (15625) ) ) )) (CELL (CELLTYPE "VITALbuf" ) (INSTANCE %LABEL%/TRP) (DELAY (ABSOLUTE ( DEVICE (20) ) ) )) (CELL (CELLTYPE "VITALbuf" ) (INSTANCE %LABEL%/TWR) (DELAY (ABSOLUTE ( DEVICE (15) ) ) )</TIMING></FMFTIME><FMFTIME>uPD45128841G5-A10-9JF<SOURCE>NEC Data Sheet M12650EJAV0DS00 January 2000</SOURCE><COMMENT> The values listed are for VCC=3V to 3.6V, CL=50pF, Ta=0 to +70 Celsius</COMMENT><COMMENT> Typical values are derived</COMMENT><TIMING> (DELAY (ABSOLUTE (IOPATH CLK DQ2 (3.0:6.0:8.0) (3.0:6.0:8.0) (3.0:6.0:8.0) (0.0:6.0:8.0) (3.0:6.0:8.0) (0.0:6.0:8.0)) (IOPATH CLK DQ3 (3.0:5.0:7.0) (3.0:5.0:7.0) (3.0:5.0:7.0) (0.0:5.0:7.0) (3.0:5.0:7.0) (0.0:5.0:7.0)) )) (TIMINGCHECK (HOLD DQ0 CLK (1.0)) (SETUP DQ0 CLK (2.5)) (WIDTH (posedge CLK) (3.5)) (WIDTH (negedge CLK) (3.5)) (PERIOD (posedge CLK) (15)) )) (CELL (CELLTYPE "VITALbuf" ) (INSTANCE %LABEL%/TRAS) (DELAY (ABSOLUTE ( DEVICE (60) (120000) ) ) ) ) (CELL (CELLTYPE "VITALbuf" ) (INSTANCE %LABEL%/TRC) (DELAY (ABSOLUTE ( DEVICE (90) ) ) )) (CELL (CELLTYPE "VITALbuf" ) (INSTANCE %LABEL%/TRCAR) (DELAY (ABSOLUTE ( DEVICE (90) ) ) )) (CELL (CELLTYPE "VITALbuf" ) (INSTANCE %LABEL%/TRCD) (DELAY (ABSOLUTE ( DEVICE (30) ) ) )) (CELL (CELLTYPE "VITALbuf" ) (INSTANCE %LABEL%/REF) (DELAY (ABSOLUTE ( DEVICE (15625) ) ) )) (CELL (CELLTYPE "VITALbuf" ) (INSTANCE %LABEL%/TRP) (DELAY (ABSOLUTE ( DEVICE (30) ) ) )) (CELL (CELLTYPE "VITALbuf" ) (INSTANCE %LABEL%/TWR) (DELAY (ABSOLUTE ( DEVICE (20) ) ) )</TIMING></FMFTIME><FMFTIME>uPD45128841G5-A10B-9JF<SOURCE>NEC Data Sheet M12650EJAV0DS00 January 2000</SOURCE><COMMENT> The values listed are for VCC=3V to 3.6V, CL=50pF, Ta=0 to +70 Celsius</COMMENT><COMMENT> Typical values are derived</COMMENT><TIMING> (DELAY (ABSOLUTE (IOPATH CLK DQ2 (3.0:6.0:8.0) (3.0:6.0:8.0) (3.0:6.0:8.0) (0.0:6.0:8.0) (3.0:6.0:8.0) (0.0:6.0:8.0)) (IOPATH CLK DQ3 (3.0:5.0:7.0) (3.0:5.0:7.0) (3.0:5.0:7.0) (0.0:5.0:7.0) (3.0:5.0:7.0) (0.0:5.0:7.0)) )) (TIMINGCHECK (HOLD DQ0 CLK (1.0)) (SETUP DQ0 CLK (2.5)) (WIDTH (posedge CLK) (3.5)) (WIDTH (negedge CLK) (3.5)) (PERIOD (posedge CLK) (15)) )) (CELL (CELLTYPE "VITALbuf" ) (INSTANCE %LABEL%/TRAS) (DELAY (ABSOLUTE ( DEVICE (60) (120000) ) ) ) ) (CELL (CELLTYPE "VITALbuf" ) (INSTANCE %LABEL%/TRC) (DELAY (ABSOLUTE ( DEVICE (90) ) ) )) (CELL (CELLTYPE "VITALbuf" ) (INSTANCE %LABEL%/TRCAR) (DELAY (ABSOLUTE ( DEVICE (90) ) ) )) (CELL (CELLTYPE "VITALbuf" ) (INSTANCE %LABEL%/TRCD) (DELAY (ABSOLUTE ( DEVICE (30) ) ) )) (CELL (CELLTYPE "VITALbuf" ) (INSTANCE %LABEL%/REF) (DELAY (ABSOLUTE ( DEVICE (15625) ) ) )) (CELL (CELLTYPE "VITALbuf" ) (INSTANCE %LABEL%/TRP) (DELAY (ABSOLUTE ( DEVICE (30) ) ) )) (CELL (CELLTYPE "VITALbuf" ) (INSTANCE %LABEL%/TWR) (DELAY (ABSOLUTE ( DEVICE (20) ) ) )</TIMING></FMFTIME><FMFTIME>K4S280832C-TC/L75<SOURCE>Samsung Electronics Data Sheet Rev. 0.0 Mar. 2000</SOURCE><COMMENT> The values listed are for VCC=3V to 3.6V, CL=50pF, Ta=0 to +70 Celsius</COMMENT><COMMENT> Typical values are derived</COMMENT><TIMING> (DELAY (ABSOLUTE (IOPATH CLK DQ2 (1.0:4.0:6.0) (1.0:4.0:6.0) (1.0:5.0:6.0) (1.0:5.0:6.0) (1.0:5.0:6.0) (1.0:5.0:6.0)) (IOPATH CLK DQ3 (1.0:4.0:6.0) (1.0:4.0:6.0) (1.0:5.0:6.0) (1.0:5.0:6.0) (1.0:5.0:6.0) (1.0:5.0:6.0)) )) (TIMINGCHECK (HOLD DQ0 CLK (1.0)) (SETUP DQ0 CLK (2.0)) (WIDTH (posedge CLK) (3.0)) (WIDTH (negedge CLK) (3.0)) (PERIOD (posedge CLK) (10)) )) (CELL (CELLTYPE "VITALbuf" ) (INSTANCE %LABEL%/TRAS) (DELAY (ABSOLUTE ( DEVICE (48) (100000) ) ) ) ) (CELL (CELLTYPE "VITALbuf" ) (INSTANCE %LABEL%/TRC) (DELAY (ABSOLUTE ( DEVICE (68) ) ) )) (CELL (CELLTYPE "VITALbuf" ) (INSTANCE %LABEL%/TRCAR) (DELAY (ABSOLUTE ( DEVICE (66) ) ) )) (CELL (CELLTYPE "VITALbuf" ) (INSTANCE %LABEL%/TRCD) (DELAY (ABSOLUTE ( DEVICE (20) ) ) )) (CELL (CELLTYPE "VITALbuf" ) (INSTANCE %LABEL%/REF) (DELAY (ABSOLUTE ( DEVICE (15625) ) ) )) (CELL (CELLTYPE "VITALbuf" ) (INSTANCE %LABEL%/TRP) (DELAY (ABSOLUTE ( DEVICE (20) ) ) )) (CELL (CELLTYPE "VITALbuf" ) (INSTANCE %LABEL%/TWR) (DELAY (ABSOLUTE ( DEVICE (15) ) ) )</TIMING></FMFTIME><FMFTIME>K4S280832C-TC/L1H<SOURCE>Samsung Electronics Data Sheet Rev. 0.0 Mar. 2000</SOURCE><COMMENT> The values listed are for VCC=3V to 3.6V, CL=50pF, Ta=0 to +70 Celsius</COMMENT><COMMENT> Typical values are derived</COMMENT><TIMING> (DELAY (ABSOLUTE (IOPATH CLK DQ2 (1.0:4.0:5.4) (1.0:4.0:5.4) (1.0:5.0:5.4) (1.0:5.0:6.0) (1.0:5.0:5.4) (1.0:5.0:6.0)) (IOPATH CLK DQ3 (1.0:4.0:6.0) (1.0:4.0:6.0) (1.0:5.0:6.0) (1.0:5.0:6.0) (1.0:5.0:6.0) (1.0:5.0:6.0)) )) (TIMINGCHECK (HOLD DQ0 CLK (1.0)) (SETUP DQ0 CLK (2.0)) (WIDTH (posedge CLK) (3.0)) (WIDTH (negedge CLK) (3.0)) (PERIOD (posedge CLK) (10)) )) (CELL (CELLTYPE "VITALbuf" ) (INSTANCE %LABEL%/TRAS) (DELAY (ABSOLUTE ( DEVICE (50) (100000) ) ) ) ) (CELL (CELLTYPE "VITALbuf" ) (INSTANCE %LABEL%/TRC) (DELAY (ABSOLUTE ( DEVICE (70) ) ) )) (CELL (CELLTYPE "VITALbuf" ) (INSTANCE %LABEL%/TRCAR) (DELAY (ABSOLUTE ( DEVICE (70) ) ) )) (CELL (CELLTYPE "VITALbuf" ) (INSTANCE %LABEL%/TRCD) (DELAY (ABSOLUTE ( DEVICE (20) ) ) )) (CELL (CELLTYPE "VITALbuf" ) (INSTANCE %LABEL%/REF) (DELAY (ABSOLUTE ( DEVICE (15625) ) ) )) (CELL (CELLTYPE "VITALbuf" ) (INSTANCE %LABEL%/TRP) (DELAY (ABSOLUTE ( DEVICE (20) ) ) )) (CELL (CELLTYPE "VITALbuf" ) (INSTANCE %LABEL%/TWR) (DELAY (ABSOLUTE ( DEVICE (15) ) ) )</TIMING></FMFTIME><FMFTIME>K4S280832C-TC/L1L<SOURCE>Samsung Electronics Data Sheet Rev. 0.0 Mar. 2000</SOURCE><COMMENT> The values listed are for VCC=3V to 3.6V, CL=50pF, Ta=0 to +70 Celsius</COMMENT><COMMENT> Typical values are derived</COMMENT><TIMING> (DELAY (ABSOLUTE (IOPATH CLK DQ2 (1.0:4.0:7.0) (1.0:4.0:7.0) (1.0:5.0:7.0) (1.0:5.0:7.0) (1.0:5.0:7.0) (1.0:5.0:7.0)) (IOPATH CLK DQ3 (1.0:4.0:6.0) (1.0:4.0:6.0) (1.0:5.0:6.0) (1.0:5.0:6.0) (1.0:5.0:6.0) (1.0:5.0:6.0)) )) (TIMINGCHECK (HOLD DQ0 CLK (1.0)) (SETUP DQ0 CLK (2.0)) (WIDTH (posedge CLK) (3.0)) (WIDTH (negedge CLK) (3.0)) (PERIOD (posedge CLK) (12)) )) (CELL (CELLTYPE "VITALbuf" ) (INSTANCE %LABEL%/TRAS) (DELAY (ABSOLUTE ( DEVICE (50) (100000) ) ) ) ) (CELL (CELLTYPE "VITALbuf" ) (INSTANCE %LABEL%/TRC) (DELAY (ABSOLUTE ( DEVICE (70) ) ) )) (CELL (CELLTYPE "VITALbuf" ) (INSTANCE %LABEL%/TRCAR) (DELAY (ABSOLUTE ( DEVICE (70) ) ) )) (CELL (CELLTYPE "VITALbuf" ) (INSTANCE %LABEL%/TRCD) (DELAY (ABSOLUTE ( DEVICE (20) ) ) )) (CELL (CELLTYPE "VITALbuf" ) (INSTANCE %LABEL%/REF) (DELAY (ABSOLUTE ( DEVICE (15625) ) ) )) (CELL (CELLTYPE "VITALbuf" ) (INSTANCE %LABEL%/TRP) (DELAY (ABSOLUTE ( DEVICE (20) ) ) )) (CELL (CELLTYPE "VITALbuf" ) (INSTANCE %LABEL%/TWR) (DELAY (ABSOLUTE ( DEVICE (15) ) ) )</TIMING></FMFTIME></BODY></FTML>
⌨️ 快捷键说明
复制代码
Ctrl + C
搜索代码
Ctrl + F
全屏模式
F11
切换主题
Ctrl + Shift + D
显示快捷键
?
增大字号
Ctrl + =
减小字号
Ctrl + -