; Statistic                                    ; Value ;
+----------------------------------------------+-------+
; Total registers                              ; 106   ;
; Number of registers using Synchronous Clear  ; 1     ;
; Number of registers using Synchronous Load   ; 0     ;
; Number of registers using Asynchronous Clear ; 0     ;
; Number of registers using Asynchronous Load  ; 0     ;
; Number of registers using Clock Enable       ; 0     ;
; Number of registers using Preset             ; 0     ;
+----------------------------------------------+-------+


+----------------------------------------------------------------------------------------------------------------------------+
; Source assignments for reg8:reg8_23|altshift_taps:out_data_rtl_0|shift_taps_c0m:auto_generated|altsyncram_e681:altsyncram2 ;
+---------------------------------+--------------------+------+--------------------------------------------------------------+
; Assignment                      ; Value              ; From ; To                                                           ;
+---------------------------------+--------------------+------+--------------------------------------------------------------+
; OPTIMIZE_POWER_DURING_SYNTHESIS ; NORMAL_COMPILATION ; -    ; -                                                            ;
+---------------------------------+--------------------+------+--------------------------------------------------------------+


+-------------------------------------------------------------+
; Parameter Settings for User Entity Instance: add8_9:add8_91 ;
+----------------+-------+------------------------------------+
; Parameter Name ; Value ; Type                               ;
+----------------+-------+------------------------------------+
; WIDTH          ; 8     ; Signed Integer                     ;
; WIDTH1         ; 8     ; Signed Integer                     ;
+----------------+-------+------------------------------------+
Note: In order to hide this table in the UI and the text report file, please set the "Show Parameter Settings Tables in Synthesis Report" option in "Analysis and Synthesis Settings -> More Settings" to "Off".


+-------------------------------------------------------------------------------+
; Parameter Settings for User Entity Instance: add8_9:add8_91|lpm_add_sub:add_1 ;
+------------------------+-------------+----------------------------------------+
; Parameter Name         ; Value       ; Type                                   ;
+------------------------+-------------+----------------------------------------+
; LPM_WIDTH              ; 8           ; Signed Integer                         ;
; LPM_REPRESENTATION     ; SIGNED      ; Untyped                                ;
; LPM_DIRECTION          ; add         ; Untyped                                ;
; ONE_INPUT_IS_CONSTANT  ; NO          ; Untyped                                ;
; LPM_PIPELINE           ; 0           ; Untyped                                ;
; MAXIMIZE_SPEED         ; 5           ; Untyped                                ;
; REGISTERED_AT_END      ; 0           ; Untyped                                ;
; OPTIMIZE_FOR_SPEED     ; 5           ; Untyped                                ;
; USE_CS_BUFFERS         ; 1           ; Untyped                                ;
; CARRY_CHAIN            ; MANUAL      ; Untyped                                ;
; CARRY_CHAIN_LENGTH     ; 48          ; CARRY_CHAIN_LENGTH                     ;
; DEVICE_FAMILY          ; Cyclone II  ; Untyped                                ;
; USE_WYS                ; OFF         ; Untyped                                ;
; STYLE                  ; FAST        ; Untyped                                ;
; CBXI_PARAMETER         ; add_sub_rjc ; Untyped                                ;
; AUTO_CARRY_CHAINS      ; ON          ; AUTO_CARRY                             ;
; IGNORE_CARRY_BUFFERS   ; OFF         ; IGNORE_CARRY                           ;
; AUTO_CASCADE_CHAINS    ; ON          ; AUTO_CASCADE                           ;
; IGNORE_CASCADE_BUFFERS ; OFF         ; IGNORE_CASCADE                         ;
+------------------------+-------------+----------------------------------------+
Note: In order to hide this table in the UI and the text report file, please set the "Show Parameter Settings Tables in Synthesis Report" option in "Analysis and Synthesis Settings -> More Settings" to "Off".


+-------------------------------------------------------------+
; Parameter Settings for User Entity Instance: add8_9:add8_92 ;
+----------------+-------+------------------------------------+
; Parameter Name ; Value ; Type                               ;
+----------------+-------+------------------------------------+
; WIDTH          ; 8     ; Signed Integer                     ;
; WIDTH1         ; 8     ; Signed Integer                     ;
+----------------+-------+------------------------------------+
Note: In order to hide this table in the UI and the text report file, please set the "Show Parameter Settings Tables in Synthesis Report" option in "Analysis and Synthesis Settings -> More Settings" to "Off".


+-------------------------------------------------------------------------------+
; Parameter Settings for User Entity Instance: add8_9:add8_92|lpm_add_sub:add_1 ;
+------------------------+-------------+----------------------------------------+
; Parameter Name         ; Value       ; Type                                   ;
+------------------------+-------------+----------------------------------------+
; LPM_WIDTH              ; 8           ; Signed Integer                         ;
; LPM_REPRESENTATION     ; SIGNED      ; Untyped                                ;
; LPM_DIRECTION          ; add         ; Untyped                                ;
; ONE_INPUT_IS_CONSTANT  ; NO          ; Untyped                                ;
; LPM_PIPELINE           ; 0           ; Untyped                                ;
; MAXIMIZE_SPEED         ; 5           ; Untyped                                ;
; REGISTERED_AT_END      ; 0           ; Untyped                                ;
; OPTIMIZE_FOR_SPEED     ; 5           ; Untyped                                ;
; USE_CS_BUFFERS         ; 1           ; Untyped                                ;
; CARRY_CHAIN            ; MANUAL      ; Untyped                                ;
; CARRY_CHAIN_LENGTH     ; 48          ; CARRY_CHAIN_LENGTH                     ;
; DEVICE_FAMILY          ; Cyclone II  ; Untyped                                ;
; USE_WYS                ; OFF         ; Untyped                                ;
; STYLE                  ; FAST        ; Untyped                                ;
; CBXI_PARAMETER         ; add_sub_rjc ; Untyped                                ;
; AUTO_CARRY_CHAINS      ; ON          ; AUTO_CARRY                             ;
; IGNORE_CARRY_BUFFERS   ; OFF         ; IGNORE_CARRY                           ;
; AUTO_CASCADE_CHAINS    ; ON          ; AUTO_CASCADE                           ;
; IGNORE_CASCADE_BUFFERS ; OFF         ; IGNORE_CASCADE                         ;
+------------------------+-------------+----------------------------------------+
Note: In order to hide this table in the UI and the text report file, please set the "Show Parameter Settings Tables in Synthesis Report" option in "Analysis and Synthesis Settings -> More Settings" to "Off".


+----------------------------------------------------------+
; Parameter Settings for User Entity Instance: add_1p:add9 ;
+----------------+-------+---------------------------------+
; Parameter Name ; Value ; Type                            ;
+----------------+-------+---------------------------------+
; WIDTH          ; 9     ; Signed Integer                  ;
; WIDTH1         ; 7     ; Signed Integer                  ;
; WIDTH2         ; 2     ; Signed Integer                  ;
+----------------+-------+---------------------------------+
Note: In order to hide this table in the UI and the text report file, please set the "Show Parameter Settings Tables in Synthesis Report" option in "Analysis and Synthesis Settings -> More Settings" to "Off".


+----------------------------------------------------------------------------+
; Parameter Settings for User Entity Instance: add_1p:add9|lpm_add_sub:add_1 ;
+------------------------+-------------+-------------------------------------+
; Parameter Name         ; Value       ; Type                                ;
+------------------------+-------------+-------------------------------------+
; LPM_WIDTH              ; 7           ; Signed Integer                      ;
; LPM_REPRESENTATION     ; SIGNED      ; Untyped                             ;
; LPM_DIRECTION          ; add         ; Untyped                             ;
; ONE_INPUT_IS_CONSTANT  ; NO          ; Untyped                             ;
; LPM_PIPELINE           ; 0           ; Untyped                             ;
; MAXIMIZE_SPEED         ; 5           ; Untyped                             ;
; REGISTERED_AT_END      ; 0           ; Untyped                             ;
; OPTIMIZE_FOR_SPEED     ; 5           ; Untyped                             ;
; USE_CS_BUFFERS         ; 1           ; Untyped                             ;
; CARRY_CHAIN            ; MANUAL      ; Untyped                             ;
; CARRY_CHAIN_LENGTH     ; 48          ; CARRY_CHAIN_LENGTH                  ;
; DEVICE_FAMILY          ; Cyclone II  ; Untyped                             ;
; USE_WYS                ; OFF         ; Untyped                             ;
; STYLE                  ; FAST        ; Untyped                             ;
; CBXI_PARAMETER         ; add_sub_qjc ; Untyped                             ;
; AUTO_CARRY_CHAINS      ; ON          ; AUTO_CARRY                          ;
; IGNORE_CARRY_BUFFERS   ; OFF         ; IGNORE_CARRY                        ;
; AUTO_CASCADE_CHAINS    ; ON          ; AUTO_CASCADE                        ;
; IGNORE_CASCADE_BUFFERS ; OFF         ; IGNORE_CASCADE                      ;
+------------------------+-------------+-------------------------------------+
Note: In order to hide this table in the UI and the text report file, please set the "Show Parameter Settings Tables in Synthesis Report" option in "Analysis and Synthesis Settings -> More Settings" to "Off".