⭐ 欢迎来到虫虫下载站! | 📦 资源下载 📁 资源专辑 ℹ️ 关于我们
⭐ 虫虫下载站

📄 symbol.xml

📁 Barcode label printing on Zebra printers Using Print DLL s. To use this code, we have to download su
💻 XML
📖 第 1 页 / 共 5 页
字号:
        </member>
        <member name="F:Symbol.Results.MSR3000_ERR_PARAMETER">
            <summary>
            Incorrect parameter sent to MSR C API.
            </summary>
        </member>
        <member name="F:Symbol.Results.MSR3000_ERR_SIZE">
            <summary>
            Incorrect buffer size for MSR C API.
            </summary>
        </member>
        <member name="F:Symbol.Results.MSR3000_ERR_NODATA">
            <summary>
            No data read from MSR C API.
            </summary>
        </member>
        <member name="F:Symbol.Results.MSR3000_ERR_OSERROR">
            <summary>
            An Operating System error occured while accessing MSR C API.
            </summary>
        </member>
        <member name="F:Symbol.Results.MSR3000_ERR_DEVICEREMOVED">
            <summary>
            MSR hardware was removed.
            </summary>
        </member>
        <member name="F:Symbol.Results.E_SCN_OPENINGACTIVEKEY">
            <summary>
            A Scanner error occurred opening the active driver registry key.
            </summary>
        </member>
        <member name="F:Symbol.Results.E_SCN_READINGACTIVEKEY">
            <summary>
            A Scanner error occurred reading the active driver registry key.
            </summary>
        </member>
        <member name="F:Symbol.Results.E_SCN_OPENINGPARAMKEY">
            <summary>
            A Scanner error occurred opening the registry key containing the driver's settings.
            </summary>
        </member>
        <member name="F:Symbol.Results.E_SCN_READINGPARAMKEY">
            <summary>
            A Scanner error occurred reading the registry key containing the driver's settings.
            </summary>
        </member>
        <member name="F:Symbol.Results.E_SCN_NOTENOUGHMEMORY">
            <summary>
            An attempt to allocate memory for scanner failed.
            </summary>
        </member>
        <member name="F:Symbol.Results.E_SCN_INVALIDDVCCONTEXT">
            <summary>
            An invalid scanner device context ID was used.
            </summary>
        </member>
        <member name="F:Symbol.Results.E_SCN_INVALIDOPENCONTEXT">
            <summary>
            An attempt was made to access an invalid scanner open context.
            </summary>
        </member>
        <member name="F:Symbol.Results.E_SCN_NOTINITIALIZED">
            <summary>
            The scanner driver was accessed before a successful initialization.
            </summary>
        </member>
        <member name="F:Symbol.Results.E_SCN_CANTLOADDEVICE">
            <summary>
            The physical device driver (PDD) for scanner could not be loaded.
            </summary>
        </member>
        <member name="F:Symbol.Results.E_SCN_INVALIDDEVICE">
            <summary>
            The physical device driver (PDD) DLL for scanner did not contain the required entry points.
            </summary>
        </member>
        <member name="F:Symbol.Results.E_SCN_DEVICEFAILURE">
            <summary>
            Required scanner device is not present, already in use or not functioning properly.
            </summary>
        </member>
        <member name="F:Symbol.Results.E_SCN_CANTSTARTDEVICE">
            <summary>
            The scanner device could not be started.
            </summary>
        </member>
        <member name="F:Symbol.Results.E_SCN_CANTGETDEFAULTS">
            <summary>
            The default scanner parameters could not be obtained from the physical device driver (PDD).
            </summary>
        </member>
        <member name="F:Symbol.Results.E_SCN_NOTSTARTED">
            <summary>
            An attempt was made to use or stop the scanner device and it was not started.
            </summary>
        </member>
        <member name="F:Symbol.Results.E_SCN_ALREADYSTARTED">
            <summary>
            An attempt was made to start the scanner device when the device was already started.
            </summary>
        </member>
        <member name="F:Symbol.Results.E_SCN_NOTENABLED">
            <summary>
            An attempt was made to access the scanner device and it was not enabled.
            </summary>
        </member>
        <member name="F:Symbol.Results.E_SCN_ALREADYENABLED">
            <summary>
            An attempt was made to enable scanning when scanning was already enabled.
            </summary>
        </member>
        <member name="F:Symbol.Results.E_SCN_INVALIDIOCTRL">
            <summary>
            The control code passed to DeviceIoControl of the scanner is invalid.
            </summary>
        </member>
        <member name="F:Symbol.Results.E_SCN_NULLPTR">
            <summary>
            A NULL pointer was passed for a required argument.
            </summary>
        </member>
        <member name="F:Symbol.Results.E_SCN_INVALIDARG">
            <summary>
            A passed argument is out of range.
            </summary>
        </member>
        <member name="F:Symbol.Results.E_SCN_BUFFERSIZEIN">
            <summary>
            The size of the buffer passed as an input to DeviceIoControl is less than sizeof(STRUCT_INFO) or is less than the size specified in StructInfo.dwUsed.
            </summary>
        </member>
        <member name="F:Symbol.Results.E_SCN_BUFFERSIZEOUT">
            <summary>
            The size of the buffer passed as an output to DeviceIoControl is less than sizeof(STRUCT_INFO) or is less than the size specified in StructInfo.dwAllocated.
            </summary>
        </member>
        <member name="F:Symbol.Results.E_SCN_STRUCTSIZE">
            <summary>
            A STRUCT_INFO structure field is invalid. Either dwAllocated or dwUsed is less than the size of STRUCT_INFO or dwUsed is greater than dwAllocated.
            </summary>
        </member>
        <member name="F:Symbol.Results.E_SCN_MISSINGFIELD">
            <summary>
            The size of a structure specified in a StructInfo is too small to contain a required field.
            </summary>
        </member>
        <member name="F:Symbol.Results.E_SCN_INVALIDHANDLE">
            <summary>
            An invalid handle was passed to a function.
            </summary>
        </member>
        <member name="F:Symbol.Results.E_SCN_INVALIDPARAM">
            <summary>
            The value of a parameter either passed as an argument to a function or as a member of a structure is out of range or conflicts with other parameters.
            </summary>
        </member>
        <member name="F:Symbol.Results.E_SCN_CREATEEVENT">
            <summary>
            Unable to create a required event.
            </summary>
        </member>
        <member name="F:Symbol.Results.E_SCN_CREATETHREAD">
            <summary>
            Unable to create a required thread.
            </summary>
        </member>
        <member name="F:Symbol.Results.E_SCN_READCANCELLED">
            <summary>
            A read request was cancelled.
            </summary>
        </member>
        <member name="F:Symbol.Results.E_SCN_READTIMEOUT">
            <summary>
            A read request timed out.
            </summary>
        </member>
        <member name="F:Symbol.Results.E_SCN_READNOTPENDING">
            <summary>
            Attempt to cancel a read that is not pending.
            </summary>
        </member>
        <member name="F:Symbol.Results.E_SCN_READPENDING">
            <summary>
            Attempt to start a read when one is pending.
            </summary>
        </member>
        <member name="F:Symbol.Results.E_SCN_BUFFERTOOSMALL">
            <summary>
            Data buffer is too small for incoming data.
            </summary>
        </member>
        <member name="F:Symbol.Results.E_SCN_INVALIDSCANBUFFER">
            <summary>
            Attempt to access fields of an invalid scan buffer.
            </summary>
        </member>
        <member name="F:Symbol.Results.E_SCN_READINCOMPATIBLE">
            <summary>
            Attempt to submit a read that is incompatible with reads already queued.
            </summary>
        </member>
        <member name="F:Symbol.Results.E_SCN_NOFEEDBACK">
            <summary>
            Attempt to perform physical device driver (PDD) feedback with no feedback capabilities.
            </summary>
        </member>
        <member name="F:Symbol.Results.E_SCN_NOTSUPPORTED">
            <summary>
            Version of function not supported (e.g. ANSI vs. UNICODE).
            </summary>
        </member>
        <member name="F:Symbol.Results.E_SCN_WRONGSTATE">
            <summary>
            The requested operation is inconsistent with the current state of the device.
            </summary>
        </member>
        <member name="F:Symbol.Results.E_SCN_NOMOREITEMS">
            <summary>
            No more items are available to be returned from SCAN_FindFirst/SCAN_FindNext.
            </summary>
        </member>
        <member name="F:Symbol.Results.E_SCN_CANTOPENREGKEY">
            <summary>
            A required registry key could not be opened.
            </summary>
        </member>
        <member name="F:Symbol.Results.E_SCN_CANTREADREGVAL">
            <summary>
            A required registry value could not be read.
            </summary>
        </member>
        <member name="F:Symbol.Results.E_SCN_EXCEPTION">
            <summary>
            An exception occurred while trying to call the scanner driver.
            </summary>
        </member>
        <member name="F:Symbol.Results.E_SCN_WIN32ERROR">
            <summary>
            A scanner API function failed with a non-scanner API error code. Call GetLastError to get extended error code.
            </summary>
        </member>
        <member name="F:Symbol.Results.E_SCN_ALREADYINUSE">
            <summary>
            A requested scanner resource is already in use.
            </summary>
        </member>
        <member name="F:Symbol.Results.E_SCN_NOTINUSE">
            <summary>
            The specified scanner resource was not allocated.
            </summary>
        </member>
        <member name="F:Symbol.Results.E_SCN_CANTLOADDECODERDLL">
            <summary>
            The specified decoder DLL can not be loaded.
            </summary>
        </member>
        <member name="F:Symbol.Results.E_SCN_INVALIDDECODERDLL">
            <summary>
            At least one API is missing in Decoder DLL.
            </summary>
        </member>
        <member name="F:Symbol.Results.E_SCN_INVALIDSYMBOL">
            <summary>
            The symbol's format is invalid.
            </summary>
        </member>
        <member name="F:Symbol.Results.E_SCN_INVALIDLICENSE">
            <summary>
            The platform does not have a valid license key.
            </summary>
        </member>
        <member name="F:Symbol.Results.E_SCN_NOTINSEQUENCE">
            <summary>
            The scanned macro symbol is not part of the current macro sequence.
            </summary>
        </member>
        <member name="F:Symbol.Results.E_SCN_DUPLICATESYMBOL">
            <summary>
            The scanned macro symbol has already been scanned into the current macro sequence.
            </summary>
        </member>
        <member name="F:Symbol.Results.E_SCN_CANTLOADHALDLL">
            <summary>
            The Image HAL DLL can not be loaded.
            </summary>
        </member>
        <member name="F:Symbol.Results.E_SCN_INVALIDHALDLL">
            <summary>
            At least one API function is missing in Image HAL DLL.
            </summary>
        </member>
        <member name="F:Symbol.Results.E_SCN_CANTLOADCOMPRESSIONDLL">
            <summary>
            The Image Compression DLL can not be loaded.
            </summary>
        </member>
        <member name="F:Symbol.Results.MSR_SUCCESS">
            <summary>
            The function completed successfully.

⌨️ 快捷键说明

复制代码 Ctrl + C
搜索代码 Ctrl + F
全屏模式 F11
切换主题 Ctrl + Shift + D
显示快捷键 ?
增大字号 Ctrl + =
减小字号 Ctrl + -