📄 serialport.map.rpt
字号:
+----------------------+----------------------+
; Logic cells ; 128 ;
; Total registers ; 98 ;
; I/O pins ; 10 ;
; Shareable expanders ; 7 ;
; Parallel expanders ; 21 ;
; Maximum fan-out node ; reset ;
; Maximum fan-out ; 99 ;
; Total fan-out ; 1997 ;
; Average fan-out ; 13.77 ;
+----------------------+----------------------+
+--------------------------------------------------------------------------------------------------------------------------+
; Analysis & Synthesis Resource Utilization by Entity ;
+-----------------------------------------+------------+------+------------------------------------------------------------+
; Compilation Hierarchy Node ; Macrocells ; Pins ; Full Hierarchy Name ;
+-----------------------------------------+------------+------+------------------------------------------------------------+
; |serialport ; 128 ; 10 ; |serialport ;
; |baud_div:inst5| ; 21 ; 0 ; |serialport|baud_div:inst5 ;
; |lpm_counter:delay_counter_rtl_2| ; 18 ; 0 ; |serialport|baud_div:inst5|lpm_counter:delay_counter_rtl_2 ;
; |bcd_ascii:inst2| ; 3 ; 0 ; |serialport|bcd_ascii:inst2 ;
; |counter:inst3| ; 1 ; 0 ; |serialport|counter:inst3 ;
; |counter_out:inst| ; 30 ; 0 ; |serialport|counter_out:inst ;
; |lpm_counter:counter_rtl_0| ; 4 ; 0 ; |serialport|counter_out:inst|lpm_counter:counter_rtl_0 ;
; |pwm:inst1| ; 33 ; 0 ; |serialport|pwm:inst1 ;
; |lpm_counter:delay_counter_rtl_1| ; 32 ; 0 ; |serialport|pwm:inst1|lpm_counter:delay_counter_rtl_1 ;
; |serialport_tx:inst7| ; 37 ; 0 ; |serialport|serialport_tx:inst7 ;
+-----------------------------------------+------------+------+------------------------------------------------------------+
+--------------------------------------------------------+
; Parameter Settings for User Entity Instance: pwm:inst1 ;
+----------------+-------+-------------------------------+
; Parameter Name ; Value ; Type ;
+----------------+-------+-------------------------------+
; pulse_width ; 2 ; Untyped ;
+----------------+-------+-------------------------------+
Note: In order to hide this table in the UI and the text report file, please set the "Show Parameter Settings Tables in Synthesis Report" option in "Analysis and Synthesis Settings -> More Settings" to "Off".
+---------------------------------------------------------------+
; Parameter Settings for User Entity Instance: counter_out:inst ;
+----------------+----------+-----------------------------------+
; Parameter Name ; Value ; Type ;
+----------------+----------+-----------------------------------+
; divisor ; 24000000 ; Untyped ;
; unit ; 1111 ; Untyped ;
+----------------+----------+-----------------------------------+
Note: In order to hide this table in the UI and the text report file, please set the "Show Parameter Settings Tables in Synthesis Report" option in "Analysis and Synthesis Settings -> More Settings" to "Off".
+------------------------------------------------------------+
; Parameter Settings for User Entity Instance: counter:inst3 ;
+----------------+-------+-----------------------------------+
; Parameter Name ; Value ; Type ;
+----------------+-------+-----------------------------------+
; divisor ; 2 ; Untyped ;
+----------------+-------+-----------------------------------+
Note: In order to hide this table in the UI and the text report file, please set the "Show Parameter Settings Tables in Synthesis Report" option in "Analysis and Synthesis Settings -> More Settings" to "Off".
+--------------------------------------------------------------+
; Parameter Settings for User Entity Instance: bcd_ascii:inst2 ;
+----------------+-------+-------------------------------------+
; Parameter Name ; Value ; Type ;
+----------------+-------+-------------------------------------+
; data_width ; 4 ; Untyped ;
+----------------+-------+-------------------------------------+
Note: In order to hide this table in the UI and the text report file, please set the "Show Parameter Settings Tables in Synthesis Report" option in "Analysis and Synthesis Settings -> More Settings" to "Off".
+---------------------------------------------------------------------------------------------+
; Parameter Settings for Inferred Entity Instance: counter_out:inst|lpm_counter:counter_rtl_0 ;
+------------------------+-------------------+------------------------------------------------+
; Parameter Name ; Value ; Type ;
+------------------------+-------------------+------------------------------------------------+
; AUTO_CARRY_CHAINS ; ON ; AUTO_CARRY ;
; IGNORE_CARRY_BUFFERS ; OFF ; IGNORE_CARRY ;
; AUTO_CASCADE_CHAINS ; ON ; AUTO_CASCADE ;
; IGNORE_CASCADE_BUFFERS ; OFF ; IGNORE_CASCADE ;
; LPM_WIDTH ; 4 ; Untyped ;
; LPM_DIRECTION ; UP ; Untyped ;
; LPM_MODULUS ; 0 ; Untyped ;
; LPM_AVALUE ; UNUSED ; Untyped ;
; LPM_SVALUE ; UNUSED ; Untyped ;
; LPM_PORT_UPDOWN ; PORT_CONNECTIVITY ; Untyped ;
; DEVICE_FAMILY ; MAX3000A ; Untyped ;
; CARRY_CHAIN ; MANUAL ; Untyped ;
; CARRY_CHAIN_LENGTH ; 48 ; CARRY_CHAIN_LENGTH ;
; NOT_GATE_PUSH_BACK ; ON ; NOT_GATE_PUSH_BACK ;
; CARRY_CNT_EN ; SMART ; Untyped ;
; LABWIDE_SCLR ; ON ; Untyped ;
; USE_NEW_VERSION ; TRUE ; Untyped ;
; CBXI_PARAMETER ; NOTHING ; Untyped ;
+------------------------+-------------------+------------------------------------------------+
Note: In order to hide this table in the UI and the text report file, please set the "Show Parameter Settings Tables in Synthesis Report" option in "Analysis and Synthesis Settings -> More Settings" to "Off".
+--------------------------------------------------------------------------------------------+
; Parameter Settings for Inferred Entity Instance: pwm:inst1|lpm_counter:delay_counter_rtl_1 ;
+------------------------+-------------------+-----------------------------------------------+
; Parameter Name ; Value ; Type ;
+------------------------+-------------------+-----------------------------------------------+
; AUTO_CARRY_CHAINS ; ON ; AUTO_CARRY ;
; IGNORE_CARRY_BUFFERS ; OFF ; IGNORE_CARRY ;
; AUTO_CASCADE_CHAINS ; ON ; AUTO_CASCADE ;
; IGNORE_CASCADE_BUFFERS ; OFF ; IGNORE_CASCADE ;
; LPM_WIDTH ; 32 ; Untyped ;
; LPM_DIRECTION ; UP ; Untyped ;
; LPM_MODULUS ; 0 ; Untyped ;
; LPM_AVALUE ; UNUSED ; Untyped ;
; LPM_SVALUE ; UNUSED ; Untyped ;
; LPM_PORT_UPDOWN ; PORT_CONNECTIVITY ; Untyped ;
; DEVICE_FAMILY ; MAX3000A ; Untyped ;
; CARRY_CHAIN ; MANUAL ; Untyped ;
; CARRY_CHAIN_LENGTH ; 48 ; CARRY_CHAIN_LENGTH ;
; NOT_GATE_PUSH_BACK ; ON ; NOT_GATE_PUSH_BACK ;
; CARRY_CNT_EN ; SMART ; Untyped ;
; LABWIDE_SCLR ; ON ; Untyped ;
; USE_NEW_VERSION ; TRUE ; Untyped ;
; CBXI_PARAMETER ; NOTHING ; Untyped ;
+------------------------+-------------------+-----------------------------------------------+
Note: In order to hide this table in the UI and the text report file, please set the "Show Parameter Settings Tables in Synthesis Report" option in "Analysis and Synthesis Settings -> More Settings" to "Off".
+-------------------------------------------------------------------------------------------------+
; Parameter Settings for Inferred Entity Instance: baud_div:inst5|lpm_counter:delay_counter_rtl_2 ;
+------------------------+-------------------+----------------------------------------------------+
; Parameter Name ; Value ; Type ;
+------------------------+-------------------+----------------------------------------------------+
; AUTO_CARRY_CHAINS ; ON ; AUTO_CARRY ;
; IGNORE_CARRY_BUFFERS ; OFF ; IGNORE_CARRY ;
; AUTO_CASCADE_CHAINS ; ON ; AUTO_CASCADE ;
; IGNORE_CASCADE_BUFFERS ; OFF ; IGNORE_CASCADE ;
; LPM_WIDTH ; 18 ; Untyped ;
; LPM_DIRECTION ; UP ; Untyped ;
; LPM_MODULUS ; 0 ; Untyped ;
; LPM_AVALUE ; UNUSED ; Untyped ;
; LPM_SVALUE ; UNUSED ; Untyped ;
; LPM_PORT_UPDOWN ; PORT_CONNECTIVITY ; Untyped ;
; DEVICE_FAMILY ; MAX3000A ; Untyped ;
; CARRY_CHAIN ; MANUAL ; Untyped ;
; CARRY_CHAIN_LENGTH ; 48 ; CARRY_CHAIN_LENGTH ;
; NOT_GATE_PUSH_BACK ; ON ; NOT_GATE_PUSH_BACK ;
; CARRY_CNT_EN ; SMART ; Untyped ;
; LABWIDE_SCLR ; ON ; Untyped ;
; USE_NEW_VERSION ; TRUE ; Untyped ;
⌨️ 快捷键说明
复制代码
Ctrl + C
搜索代码
Ctrl + F
全屏模式
F11
切换主题
Ctrl + Shift + D
显示快捷键
?
增大字号
Ctrl + =
减小字号
Ctrl + -