📄 pinball.pow.rpt
字号:
; d ; Logic cell ; 0.00 mW ; 0.00 mW ; -- ;
; a~14 ; Logic cell ; 0.00 mW ; 0.00 mW ; -- ;
; clk ; I/O ; 0.04 mW ; 0.00 mW ; 0.04 mW ;
; keyIn ; I/O ; 0.00 mW ; 0.00 mW ; 0.00 mW ;
; keyOut ; I/O ; 0.00 mW ; 0.00 mW ; 0.00 mW ;
; ~nCSO~ ; I/O ; 0.00 mW ; 0.00 mW ; 0.00 mW ;
; ~ASDO~ ; I/O ; 0.00 mW ; 0.00 mW ; 0.00 mW ;
+------------+------------+-----------------------------------+---------------------------------------+----------------------------+
(1) The "Block Thermal Static Power" for all block types except Pins is part of the "Static Thermal Power Dissipation" value found on the PowerPlay Power Analyzer-->Summary report panel. The "Static Thermal Power Dissipation" also contains the thermal static power dissipated by the routing.
+---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------+
; Thermal Power Dissipation by Block Type ;
+------------+-----------------------------------+---------------------------------------+----------------------------+-----------------------------------------------------------+
; Block Type ; Total Thermal Power by Block Type ; Block & Routing Thermal Dynamic Power ; Block Thermal Static Power ; Block Average Toggle Rate (millions of transitions / sec) ;
+------------+-----------------------------------+---------------------------------------+----------------------------+-----------------------------------------------------------+
; Logic cell ; 0.00 mW ; 0.00 mW ; -- ; 0.000 ;
; I/O ; 0.04 mW ; 0.00 mW ; 0.04 mW ; 0.000 ;
+------------+-----------------------------------+---------------------------------------+----------------------------+-----------------------------------------------------------+
(1) The "Block Thermal Static Power" for all block types except Pins and the Voltage Regulator, if one exists, is part of the "Static Thermal Power Dissipation" value found on the PowerPlay Power Analyzer-->Summary report panel. The "Static Thermal Power Dissipation" also contains the thermal static power dissipated by the routing.
+----------------------------------------------------------------------------------------------------------------------------------------------------------------------+
; Thermal Power Dissipation by Hierarchy ;
+----------------------------+--------------------------------------+-------------------------------------------+--------------------------------+---------------------+
; Compilation Hierarchy Node ; Total Thermal Power by Hierarchy (1) ; Block & Routing Thermal Dynamic Power (1) ; Block Thermal Static Power (1) ; Full Hierarchy Name ;
+----------------------------+--------------------------------------+-------------------------------------------+--------------------------------+---------------------+
; |input ; 0.04 mW (0.04 mW) ; 0.00 mW (0.00 mW) ; 0.04 mW (0.04 mW) ; |input ;
+----------------------------+--------------------------------------+-------------------------------------------+--------------------------------+---------------------+
(1) Value in parentheses is the power consumed at that level of hierarchy. Value not in parentheses is the power consumed at that level of hierarchy plus the power consumed by all levels of hierarchy below it.
(2) The "Block Thermal Static Power" for all levels of hierarchy except the top-level hierarchy is part of the "Static Thermal Power Dissipation" value found on the PowerPlay Power Analyzer-->Summary report panel. The "Static Thermal Power Dissipation" also contains the thermal static power dissipated by the routing.
+-----------------------------------------------------------------------------------------------------------------------------------+
; Confidence Metric Details ;
+----------------------------------------------------------------------------------------+-------+-----+------------+---------------+
; Data Source ; Total ; Pin ; Registered ; Combinational ;
+----------------------------------------------------------------------------------------+-------+-----+------------+---------------+
; Simulation (from file) ; ; ; ; ;
; -- Number of signals with Toggle Rate from Simulation ; 0 ; 0 ; 0 ; 0 ;
; -- Number of signals with Static Probability from Simulation ; 0 ; 0 ; 0 ; 0 ;
; ; ; ; ; ;
; Node, entity or clock assignment ; ; ; ; ;
; -- Number of signals with Toggle Rate from Node, entity or clock assignment ; 0 ; 0 ; 0 ; 0 ;
; -- Number of signals with Static Probability from Node, entity or clock assignment ; 0 ; 0 ; 0 ; 0 ;
; ; ; ; ; ;
; Vectorless estimation ; ; ; ; ;
; -- Number of signals with Toggle Rate from Vectorless estimation ; 0 ; 0 ; 0 ; 0 ;
; -- Number of signals with Static Probability from Vectorless estimation ; 0 ; 0 ; 0 ; 0 ;
; ; ; ; ; ;
; Default assignment ; ; ; ; ;
; -- Number of signals with Toggle Rate from Default assignment ; 0 ; 0 ; 0 ; 0 ;
; -- Number of signals with Static Probability from Default assignment ; 8 ; 5 ; 1 ; 2 ;
; ; ; ; ; ;
; Assumed 0 ; ; ; ; ;
; -- Number of signals with Toggle Rate assumed 0 ; 8 ; 5 ; 1 ; 2 ;
+----------------------------------------------------------------------------------------+-------+-----+------------+---------------+
+--------------------------------------------------------------------------------------------------------------------------------------------------------+
; Signal Activities ;
+----------+---------------+---------------------------------------------+-------------------------+--------------------+--------------------------------+
; Signal ; Type ; Toggle Rate (millions of transitions / sec) ; Toggle Rate Data Source ; Static Probability ; Static Probability Data Source ;
+----------+---------------+---------------------------------------------+-------------------------+--------------------+--------------------------------+
; a~14 ; Combinational ; 0.000 ; Assumed 0 ; 0.500 ; Default assignment ;
; c ; Registered ; 0.000 ; Assumed 0 ; 0.500 ; Default assignment ;
; clk ; Pin ; 0.000 ; Assumed 0 ; 0.500 ; Default assignment ;
; d ; Registered ; 0.000 ; Assumed 0 ; 0.500 ; Default assignment ;
; keyIn ; Pin ; 0.000 ; Assumed 0 ; 0.500 ; Default assignment ;
; keyOut ; Pin ; 0.000 ; Assumed 0 ; 0.500 ; Default assignment ;
; keyOut~0 ; Combinational ; 0.000 ; Assumed 0 ; 0.500 ; Default assignment ;
; ~ASDO~ ; Pin ; 0.000 ; Assumed 0 ; 0.500 ; Default assignment ;
; ~nCSO~ ; Pin ; 0.000 ; Assumed 0 ; 0.500 ; Default assignment ;
+----------+---------------+---------------------------------------------+-------------------------+--------------------+--------------------------------+
+-----------------------------------+
; PowerPlay Power Analyzer Messages ;
+-----------------------------------+
Info: *******************************************************************
Info: Running Quartus II PowerPlay Power Analyzer
Info: Version 5.1 Build 176 10/26/2005 SJ Full Version
Info: Processing started: Wed May 30 16:16:18 2007
Info: Command: quartus_pow --read_settings_files=on --write_settings_files=off Pinball -c Pinball
Warning: Timing Analysis found one or more latches implemented as combinational loops
Warning: Node "a~14" is a latch
Warning: Relative toggle rates could not be calculated because no clock domain could be identified for some nodes
Info: Total thermal power estimate for the design is 60.04 mW
Info: Quartus II PowerPlay Power Analyzer was successful. 0 errors, 3 warnings
Info: Processing ended: Wed May 30 16:16:18 2007
Info: Elapsed time: 00:00:01
⌨️ 快捷键说明
复制代码
Ctrl + C
搜索代码
Ctrl + F
全屏模式
F11
切换主题
Ctrl + Shift + D
显示快捷键
?
增大字号
Ctrl + =
减小字号
Ctrl + -