📄 rfc1382.txt
字号:
x25AdmnMinimumRecallTimer OBJECT-TYPE SYNTAX PositiveInteger ACCESS read-write STATUS mandatory DESCRIPTIONThroop [Page 12]RFC 1382 X.25 Packet Layer MIB November 1992 "Minimum time interval between unsuccessful call attempts in milliseconds." REFERENCE "10733 5.9 minimum RecallTimer" ::= { x25AdmnEntry 14 } x25AdmnRestartCount OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write STATUS mandatory DESCRIPTION "The R20 restart retransmission count." REFERENCE "10733 5.9 restartCount; See ISO 8208 Section 4.1, table 27" ::= { x25AdmnEntry 15 } x25AdmnResetCount OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write STATUS mandatory DESCRIPTION "The r22 Reset retransmission count." REFERENCE "10733 resetCount; See section ISO 8208 8.1, table 27" ::= { x25AdmnEntry 16 } x25AdmnClearCount OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write STATUS mandatory DESCRIPTION "The r23 Clear retransmission count." REFERENCE "10733 clearCount; See ISO 8208 Section 5.5.1, table 27" ::= { x25AdmnEntry 17 } x25AdmnDataRxmtCount OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write STATUS mandatory DESCRIPTION "The R25 Data retransmission count. This value is irrelevant if the x25AdmnDataRxmtTimer indicates no timer in use." REFERENCE "10733 5.10.1 dataRetransmissionCount (opt) See ISO 8208 Section 11.2.1, table 27" ::= { x25AdmnEntry 18 }Throop [Page 13]RFC 1382 X.25 Packet Layer MIB November 1992 x25AdmnRejectCount OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write STATUS mandatory DESCRIPTION "The R27 reject retransmission count. This value is irrelevant if the x25AdmnRejectTimer indicates no timer in use." REFERENCE "10733 5.10.1 dataRejectCount (opt)" ::= { x25AdmnEntry 19 } x25AdmnRegistrationRequestCount OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write STATUS mandatory DESCRIPTION "The R28 Registration retransmission Count. This value is irrelevant if the x25AdmnRegistrationRequestTimer indicates no timer in use." REFERENCE "10733 5.8.1 registrationRequestCount (opt); See ISO 8208 Section 13.1.1.1, table 27" ::= { x25AdmnEntry 20 } x25AdmnNumberPVCs OBJECT-TYPE SYNTAX INTEGER (0..4096) ACCESS read-write STATUS mandatory DESCRIPTION "The number of PVC configured for this PLE. The PVCs use channel numbers from 1 to this number." ::= { x25AdmnEntry 21 } x25AdmnDefCallParamId OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-write STATUS mandatory DESCRIPTION "This identifies the instance of the x25CallParmIndex for the entry in the x25CallParmTable which contains the default call parameters for this PLE." ::= { x25AdmnEntry 22 } x25AdmnLocalAddress OBJECT-TYPE SYNTAX X121AddressThroop [Page 14]RFC 1382 X.25 Packet Layer MIB November 1992 ACCESS read-write STATUS mandatory DESCRIPTION "The local address for this PLE subnetwork. A zero length address maybe returned by PLEs that only support PVCs." REFERENCE "10733 5.9 localDTEAddress" ::= { x25AdmnEntry 23 } x25AdmnProtocolVersionSupported OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-write STATUS mandatory DESCRIPTION "Identifies the version of the X.25 protocol this interface should support. Object identifiers for common versions are defined below in the x25ProtocolVersion subtree." REFERENCE "10733 5.9 protocolVersionSupported" ::= { x25AdmnEntry 24 } -- ########################################################### -- X.25 Operational Table -- ########################################################### x25OperTable OBJECT-TYPE SYNTAX SEQUENCE OF X25OperEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The operation parameters in use by the X.25 PLE." ::= { x25 2 } x25OperEntry OBJECT-TYPE SYNTAX X25OperEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Entries of x25OperTable." INDEX { x25OperIndex } ::= { x25OperTable 1 } X25OperEntry ::= SEQUENCE { x25OperIndex IfIndexType, x25OperInterfaceModeThroop [Page 15]RFC 1382 X.25 Packet Layer MIB November 1992 INTEGER, x25OperMaxActiveCircuits INTEGER, x25OperPacketSequencing INTEGER, x25OperRestartTimer PositiveInteger, x25OperCallTimer PositiveInteger, x25OperResetTimer PositiveInteger, x25OperClearTimer PositiveInteger, x25OperWindowTimer PositiveInteger, x25OperDataRxmtTimer PositiveInteger, x25OperInterruptTimer PositiveInteger, x25OperRejectTimer PositiveInteger, x25OperRegistrationRequestTimer PositiveInteger, x25OperMinimumRecallTimer PositiveInteger, x25OperRestartCount INTEGER, x25OperResetCount INTEGER, x25OperClearCount INTEGER, x25OperDataRxmtCount INTEGER, x25OperRejectCount INTEGER, x25OperRegistrationRequestCount INTEGER, x25OperNumberPVCs INTEGER, x25OperDefCallParamId OBJECT IDENTIFIER, x25OperLocalAddress X121Address, x25OperDataLinkId OBJECT IDENTIFIER, x25OperProtocolVersionSupported OBJECT IDENTIFIER }Throop [Page 16]RFC 1382 X.25 Packet Layer MIB November 1992 x25OperIndex OBJECT-TYPE SYNTAX IfIndexType ACCESS read-only STATUS mandatory DESCRIPTION "The ifIndex value for the X.25 interface." ::= { x25OperEntry 1 } x25OperInterfaceMode OBJECT-TYPE SYNTAX INTEGER { dte (1), dce (2), dxe (3) } ACCESS read-only STATUS mandatory DESCRIPTION "Identifies DCE/DTE mode in which the interface operates. A value of dxe indicates the role will be determined by XID negotiation at the Link Layer and that negotiation has not yet taken place." REFERENCE "10733 5.9 interfaceMode" ::= { x25OperEntry 2 } x25OperMaxActiveCircuits OBJECT-TYPE SYNTAX INTEGER (0..4096) ACCESS read-only STATUS mandatory DESCRIPTION "Maximum number of circuits this PLE can support." REFERENCE "10733 5.9 maxActiveCircuits See ISO 8208, Section 3.7" ::= { x25OperEntry 3 } x25OperPacketSequencing OBJECT-TYPE SYNTAX INTEGER { modulo8 (1), modulo128 (2) } ACCESS read-only STATUS mandatory DESCRIPTION "The modulus of the packet sequence number space." REFERENCE "10733 extendedPacketSequencing; See ISO 8208 Section 7.1.1"Throop [Page 17]RFC 1382 X.25 Packet Layer MIB November 1992 ::= { x25OperEntry 4 } x25OperRestartTimer OBJECT-TYPE SYNTAX PositiveInteger ACCESS read-only STATUS mandatory DESCRIPTION "The T20 restart timer in milliseconds." REFERENCE "10733 5.9 restartTime; See ISO 8208 Section 4.1, table 26" ::= { x25OperEntry 5 } x25OperCallTimer OBJECT-TYPE SYNTAX PositiveInteger ACCESS read-only STATUS mandatory DESCRIPTION "The T21 Call timer in milliseconds." REFERENCE "10733 callTime; See ISO 8208 Section 5.2.1, table 26" ::= { x25OperEntry 6 } x25OperResetTimer OBJECT-TYPE SYNTAX PositiveInteger ACCESS read-only STATUS mandatory DESCRIPTION "The T22 Reset timer in milliseconds." REFERENCE "10733 resetTime; See ISO 8208 Section 8.1, table 26" ::= { x25OperEntry 7 } x25OperClearTimer OBJECT-TYPE SYNTAX PositiveInteger ACCESS read-only STATUS mandatory DESCRIPTION "The T23 Clear timer in milliseconds."
⌨️ 快捷键说明
复制代码
Ctrl + C
搜索代码
Ctrl + F
全屏模式
F11
切换主题
Ctrl + Shift + D
显示快捷键
?
增大字号
Ctrl + =
减小字号
Ctrl + -