⭐ 欢迎来到虫虫下载站! | 📦 资源下载 📁 资源专辑 ℹ️ 关于我们
⭐ 虫虫下载站

📄 rfc1878.txt

📁 著名的RFC文档,其中有一些文档是已经翻译成中文的的.
💻 TXT
📖 第 1 页 / 共 2 页
字号:
RFC 1878                      Subnet Table                 December 1995                              N.N.254.0   N.N.254.N        N.N.254.255255.255.255.0   255 nets      N.N.0.0     N.N.0.N          N.N.0.2558 bit subnet    253           N.N.1.0     N.N.1.N          N.N.1.255                              N.N.252.0   N.N.252.N        N.N.252.255                              N.N.253.0   N.N.253.N        N.N.253.255                              N.N.254.0   N.N.254.N        N.N.254.255   Table 1-2 represents traditional subnetting of a Class C network   address (which is identical to extended Class B subnets).Subnet Mask     # of nets    Net. Addr.  Host Addr Range  Brodcast Addr.Bits of Subnet  hosts/subnet255.255.255.128 2 nets       N.N.N.0     N.N.N.1-126      N.N.N.1271 bit Class C   126          N.N.N.128   N.N.N.129-254    N.N.N.2559 bit Class B255.255.255.192 4 nets       N.N.N.0     N.N.N.1-62       N.N.N.632 bit Class C   62           N.N.N.64    N.N.N.65-126     N.N.N.12710 bit Class B               N.N.N.128   N.N.N.129-190    N.N.N.191                             N.N.N.192   N.N.N.193-254    N.N.N.255255.255.255.224 8 nets       N.N.N.0     N.N.N.1-30       N.N.N.313 bit Class C   30           N.N.N.32    N.N.N.33-62      N.N.N.6311 bit Class B               N.N.N.64    N.N.N.65-94      N.N.N.95                             N.N.N.96    N.N.N.97-126     N.N.N.127                             N.N.N.128   N.N.N.129-158    N.N.N.159                             N.N.N.160   N.N.N.161-190    N.N.N.191                             N.N.N.192   N.N.N.193-222    N.N.N.223                             N.N.N.224   N.N.N.225-254    N.N.N.255255.255.255.240 16 nets      N.N.N.0     N.N.N.1-14       N.N.N.154 bit Class C   14           N.N.N.16    N.N.N.17-30      N.N.N.3112 bit Class B               N.N.N.32    N.N.N.33-46      N.N.N.47                             N.N.N.48    N.N.N.49-62      N.N.N.63                             N.N.N.64    N.N.N.65-78      N.N.N.79                             N.N.N.80    N.N.N.81-94      N.N.N.95                             N.N.N.96    N.N.N.97-110     N.N.N.111                             N.N.N.112   N.N.N.113-126    N.N.N.127                             N.N.N.128   N.N.N.129-142    N.N.N.143                             N.N.N.144   N.N.N.145-158    N.N.N.159                             N.N.N.160   N.N.N.161-174    N.N.N.175                             N.N.N.176   N.N.N.177-190    N.N.N.191                             N.N.N.192   N.N.N.193-206    N.N.N.207Pummill & Manning            Informational                      [Page 5]RFC 1878                      Subnet Table                 December 1995                             N.N.N.208   N.N.N.209-222    N.N.N.223                             N.N.N.224   N.N.N.225-238    N.N.N.239                             N.N.N.240   N.N.N.241-254    N.N.N.255255.255.255.248 32 nets      N.N.N.0     N.N.N.1-6        N.N.N.75 bit Class C   6            N.N.N.8     N.N.N.9-14       N.N.N.1513 bit Class B               N.N.N.16    N.N.N.17-22      N.N.N.23                             N.N.N.24    N.N.N.25-30      N.N.N.31                             N.N.N.32    N.N.N.33-38      N.N.N.39                             N.N.N.40    N.N.N.41-46      N.N.N.47                             N.N.N.48    N.N.N.49-54      N.N.N.55                             N.N.N.56    N.N.N.57-62      N.N.N.63                             N.N.N.64    N.N.N.65-70      N.N.N.71                             N.N.N.72    N.N.N.73-78      N.N.N.79                             N.N.N.80    N.N.N.81-86      N.N.N.87                             N.N.N.88    N.N.N.89-94      N.N.N.95                             N.N.N.96    N.N.N.97-102     N.N.N.103                             N.N.N.104   N.N.N.105-110    N.N.N.111                             N.N.N.112   N.N.N.113-118    N.N.N.119                             N.N.N.120   N.N.N.121-126    N.N.N.127                             N.N.N.128   N.N.N.129-134    N.N.N.135                             N.N.N.136   N.N.N.137-142    N.N.N.143                             N.N.N.144   N.N.N.145-150    N.N.N.151                             N.N.N.152   N.N.N.153-158    N.N.N.159                             N.N.N.160   N.N.N.161-166    N.N.N.167                             N.N.N.168   N.N.N.169-174    N.N.N.175                             N.N.N.176   N.N.N.177-182    N.N.N.183                             N.N.N.184   N.N.N.185-190    N.N.N.191                             N.N.N.192   N.N.N.193-198    N.N.N.199                             N.N.N.200   N.N.N.201-206    N.N.N.207                             N.N.N.208   N.N.N.209-214    N.N.N.215                             N.N.N.216   N.N.N.217-222    N.N.N.223                             N.N.N.224   N.N.N.225-230    N.N.N.231                             N.N.N.232   N.N.N.233-238    N.N.N.239                             N.N.N.240   N.N.N.241-246    N.N.N.247                             N.N.N.248   N.N.N.249-254    N.N.N.255255.255.255.252 64 nets      N.N.N.0     N.N.N.1-2        N.N.N.36 bit Class C   2            N.N.N.4     N.N.N.5-6        N.N.N.714 bit Class B               N.N.N.8     N.N.N.9-10       N.N.N.11                             N.N.N.244   N.N.N.245-246    N.N.N.247                             N.N.N.248   N.N.N.249-250    N.N.N.251                             N.N.N.252   N.N.N.253-254    N.N.N.255Pummill & Manning            Informational                      [Page 6]RFC 1878                      Subnet Table                 December 1995   For the sake of completeness within this memo, tables 2-1 and 2-2   illistrate some options for subnet/host partions within selected   block sizes using calculations which exclude all-zeros and all-ones   subnets [2].  Many vendors only support subnetting based upon this   premise.  This practice is obsolete!  Modern software will be able to   utilize all definable networks.Table 2-1 from a /16 block# bits          Mask            Effective Subnets       Effective Hosts========        =====           =================       ===============2               255.255.192.0   2                       163823               255.255.224.0   6                       81904               255.255.240.0   14                      40945               255.255.248.0   30                      20466               255.255.252.0   62                      10227               255.255.254.0   126                     5108               255.255.255.0   254                     2549               255.255.255.128 510                     12610              255.255.255.192 1022                    6211              255.255.255.224 2046                    3012              255.255.255.240 4094                    1413              255.255.255.248 8190                    614              255.255.255.252 16382                   2Table 2-2 from a /24 block# bits          Mask            Effective Subnets       Effective Hosts========        =====           =================       ===============2               255.255.255.192 2                       623               255.255.255.224 6                       304               255.255.255.240 14                      145               255.255.255.248 30                      66               255.255.255.252 62                      2*Subnet all zeroes and all ones excluded. (Obsolete)*Host all zeroes and all ones excluded.   (Obsolete)Pummill & Manning            Informational                      [Page 7]RFC 1878                      Subnet Table                 December 1995References   [1] Mogul J., "BROADCASTING INTERNET DATAGRAMS IN THE PRESENCE OF       SUBNETS", STD 5, RFC 922, Stanford University, October 1984.   [2] Braden R., Editor, "Requirements for Internet Hosts --       Application and Support", STD 3, RFC 1123, IETF, October 1989.   [3] Fuller V., Li T., Yu J., and K. Varadhan, "Classless Inter-       Domain Routing (CIDR): an Address Assignment and Aggregation       Strategy", RFC 1519, BARRNet, cicso, Merit, OARnet, September       1993.   [4] Baker F., "Requirements for IP Version 4 Routers", RFC 1812,       cisco Systems, June 1995.   [5] Mogul J., and J. Postel, "Internet Standard Subnetting       Procedure", STD 5, RFC 950, Stanford, USC/Information Sciences       Institute, August 1985.Security Considerations   Security issues are not discussed in this memo.Authors' Addresses   Troy T. Pummill   Alantec   2115 O'Nel Drive   San Jose, CA  95131   USA   Phone: +1 408.467.4871   Fax:   +1 408.441.0272   EMail: trop@alantec.com   Bill Manning   Information Sciences Institute   University of Southern California   4676 Admiralty Way   Marina del Rey, CA 90292-6695   USA   Phone: +1 310-822-1511 x387   Fax:   +1 310-823-6714   EMail: bmanning@isi.eduPummill & Manning            Informational                      [Page 8]

⌨️ 快捷键说明

复制代码 Ctrl + C
搜索代码 Ctrl + F
全屏模式 F11
切换主题 Ctrl + Shift + D
显示快捷键 ?
增大字号 Ctrl + =
减小字号 Ctrl + -