📄 top_par.xrpt
字号:
<item label="Pin
Usage" stringID="Pin_Usage" value="DIFFS"/> <item label="Pin
Name" sort="smart" stringID="Pin_Name" value="IO_L23N_1/LDC0"/> <item stringID="Direction" value="UNUSED"/> <item label="IO Bank
Number" stringID="IO_Bank_Number" value="1"/> </row> <row stringID="row" value="71"> <item label="Pin
Number" sort="smart" stringID="Pin_Number" value="D17"/> <item label="Pin
Usage" stringID="Pin_Usage" value="DIFFM"/> <item label="Pin
Name" sort="smart" stringID="Pin_Name" value="IO_L23P_1/HDC"/> <item stringID="Direction" value="UNUSED"/> <item label="IO Bank
Number" stringID="IO_Bank_Number" value="1"/> </row> <row stringID="row" value="72"> <item label="Pin
Number" sort="smart" stringID="Pin_Number" value="D18"/> <item label="Signal
Name" stringID="Signal_Name" value="en"/> <item label="Pin
Usage" stringID="Pin_Usage" value="IBUF"/> <item label="Pin
Name" sort="smart" stringID="Pin_Name" value="IP/VREF_1"/> <item stringID="Direction" value="INPUT"/> <item label="IO
Standard" sort="smart" stringID="IO_Standard" value="LVTTL"/> <item label="IO Bank
Number" stringID="IO_Bank_Number" value="1"/> <item label="Termination" stringID="Termination" value="PULLDOWN"/> <item label="IOB
Delay" stringID="IOB_Delay" value="NONE"/> <item label="Constraint" stringID="Constraint" value="LOCATED"/> <item label="IO
Register" stringID="IO_Register" value="NO"/> <item label="Signal
Integrity" stringID="Signal_Integrity" value="NONE"/> </row> <row stringID="row" value="73"> <item label="Pin
Number" sort="smart" stringID="Pin_Number" value="E1"/> <item label="Pin
Usage" stringID="Pin_Usage" value="DIFFS"/> <item label="Pin
Name" sort="smart" stringID="Pin_Name" value="IO_L03N_3"/> <item stringID="Direction" value="UNUSED"/> <item label="IO Bank
Number" stringID="IO_Bank_Number" value="3"/> </row> <row stringID="row" value="74"> <item label="Pin
Number" sort="smart" stringID="Pin_Number" value="E2"/> <item label="Pin
Usage" stringID="Pin_Usage" value="DIFFM"/> <item label="Pin
Name" sort="smart" stringID="Pin_Name" value="IO_L03P_3"/> <item stringID="Direction" value="UNUSED"/> <item label="IO Bank
Number" stringID="IO_Bank_Number" value="3"/> </row> <row stringID="row" value="75"> <item label="Pin
Number" sort="smart" stringID="Pin_Number" value="E3"/> <item label="Pin
Name" sort="smart" stringID="Pin_Name" value="NC"/> </row> <row stringID="row" value="76"> <item label="Pin
Number" sort="smart" stringID="Pin_Number" value="E4"/> <item label="Pin
Name" sort="smart" stringID="Pin_Name" value="NC"/> </row> <row stringID="row" value="77"> <item label="Pin
Number" sort="smart" stringID="Pin_Number" value="E5"/> <item label="Pin
Name" sort="smart" stringID="Pin_Name" value="VCCINT"/> <item label="Voltage" stringID="Voltage" value="1.2"/> </row> <row stringID="row" value="78"> <item label="Pin
Number" sort="smart" stringID="Pin_Number" value="E6"/> <item label="Pin
Name" sort="smart" stringID="Pin_Name" value="NC"/> </row> <row stringID="row" value="79"> <item label="Pin
Number" sort="smart" stringID="Pin_Number" value="E7"/> <item label="Pin
Usage" stringID="Pin_Usage" value="DIFFS"/> <item label="Pin
Name" sort="smart" stringID="Pin_Name" value="IO_L19N_0/VREF_0"/> <item stringID="Direction" value="UNUSED"/> <item label="IO Bank
Number" stringID="IO_Bank_Number" value="0"/> </row> <row stringID="row" value="80"> <item label="Pin
Number" sort="smart" stringID="Pin_Number" value="E8"/> <item label="Pin
Usage" stringID="Pin_Usage" value="DIFFM"/> <item label="Pin
Name" sort="smart" stringID="Pin_Name" value="IO_L17P_0"/> <item stringID="Direction" value="UNUSED"/> <item label="IO Bank
Number" stringID="IO_Bank_Number" value="0"/> </row> <row stringID="row" value="81"> <item label="Pin
Number" sort="smart" stringID="Pin_Number" value="E9"/> <item label="Signal
Name" stringID="Signal_Name" value="led<6>"/> <item label="Pin
Usage" stringID="Pin_Usage" value="IOB"/> <item label="Pin
Name" sort="smart" stringID="Pin_Name" value="IO_L15P_0"/> <item stringID="Direction" value="TRISTATE"/> <item label="IO
Standard" sort="smart" stringID="IO_Standard" value="LVTTL"/> <item label="IO Bank
Number" stringID="IO_Bank_Number" value="0"/> <item label="Drive
(mA)" stringID="Drive" value="8"/> <item label="Slew
Rate" stringID="Slew_Rate" value="SLOW"/> <item label="Termination" stringID="Termination" value="NONE**"/> <item label="Constraint" stringID="Constraint" value="LOCATED"/> <item label="IO
Register" stringID="IO_Register" value="NO"/> <item label="Signal
Integrity" stringID="Signal_Integrity" value="NONE"/> </row> <row stringID="row" value="82"> <item label="Pin
Number" sort="smart" stringID="Pin_Number" value="E10"/> <item label="Pin
Usage" stringID="Pin_Usage" value="DIFFS"/> <item label="Pin
Name" sort="smart" stringID="Pin_Name" value="IO_L11N_0/GCLK5"/> <item stringID="Direction" value="UNUSED"/> <item label="IO Bank
Number" stringID="IO_Bank_Number" value="0"/> </row> <row stringID="row" value="83"> <item label="Pin
Number" sort="smart" stringID="Pin_Number" value="E11"/> <item label="Signal
Name" stringID="Signal_Name" value="led<2>"/> <item label="Pin
Usage" stringID="Pin_Usage" value="IOB"/> <item label="Pin
Name" sort="smart" stringID="Pin_Name" value="IO_L08P_0"/> <item stringID="Direction" value="TRISTATE"/> <item label="IO
Standard" sort="smart" stringID="IO_Standard" value="LVTTL"/> <item label="IO Bank
Number" stringID="IO_Bank_Number" value="0"/> <item label="Drive
(mA)" stringID="Drive" value="8"/> <item label="Slew
Rate" stringID="Slew_Rate" value="SLOW"/> <item label="Termination" stringID="Termination" value="NONE**"/> <item label="Constraint" stringID="Constraint" value="LOCATED"/> <item label="IO
Register" stringID="IO_Register" value="NO"/> <item label="Signal
Integrity" stringID="Signal_Integrity" value="NONE"/> </row> <row stringID="row" value="84"> <item label="Pin
Number" sort="smart" stringID="Pin_Number" value="E12"/> <item label="Signal
Name" stringID="Signal_Name" value="led<1>"/> <item label="Pin
Usage" stringID="Pin_Usage" value="IOB"/> <item label="Pin
Name" sort="smart" stringID="Pin_Name" value="IO_L06N_0"/> <item stringID="Direction" value="TRISTATE"/> <item label="IO
Standard" sort="smart" stringID="IO_Standard" value="LVTTL"/> <item label="IO Bank
Number" stringID="IO_Bank_Number" value="0"/> <item label="Drive
(mA)" stringID="Drive" value="8"/> <item label="Slew
Rate" stringID="Slew_Rate" value="SLOW"/> <item label="Termination" stringID="Termination" value="NONE**"/> <item label="Constraint" stringID="Constraint" value="LOCATED"/> <item label="IO
Register" stringID="IO_Register" value="NO"/> <item label="Signal
Integrity" stringID="Signal_Integrity" value="NONE"/> </row> <row stringID="row" value="85"> <item label="Pin
Number" sort="smart" stringID="Pin_Number" value="E13"/> <item label="Pin
Usage" stringID="Pin_Usage" value="IOB"/> <item label="Pin
Name" sort="smart" stringID="Pin_Name" value="IO"/> <item stringID="Direction" value="UNUSED"/> <item label="IO Bank
Number" stringID="IO_Bank_Number" value="0"/> </row> <row stringID="row" value="86"> <item label="Pin
Number" sort="smart" stringID="Pin_Number" value="E14"/> <item label="Pin
Name" sort="smart" stringID="Pin_Name" value="VCCINT"/> <item label="Voltage" stringID="Voltage" value="1.2"/> </row> <row stringID="row" value="87"> <item label="Pin
Number" sort="smart" stringID="Pin_Number" value="E15"/> <item label="Pin
Name" sort="smart" stringID="Pin_Name" value="NC"/> </row> <row stringID="row" value="88"> <item label="Pin
Number" sort="smart" stringID="Pin_Number" value="E16"/> <item label="Pin
Name" sort="smart" stringID="Pin_Name" value="NC"/> </row> <row stringID="row" value="89"> <item label="Pin
Number" sort="smart" stringID="Pin_Number" value="E17"/> <item label="Pin
Usage" stringID="Pin_Usage" value="IOB"/> <item label="Pin
Name" sort="smart" stringID="Pin_Name" value="IO"/> <item stringID="Direction" value="UNUSED"/> <item label="IO Bank
Number" stringID="IO_Bank_Number" value="1"/> </row> <row stringID="row" value="90"> <item label="Pin
Number" sort="smart" stringID="Pin_Number" value="E18"/> <item label="Pin
Usage" stringID="Pin_Usage" value="IBUF"/> <item label="Pin
Name" sort="smart" stringID="Pin_Name" value="IP"/> <item stringID="Direction" value="UNUSED"/> <item label="IO Bank
Number" stringID="IO_Bank_Number" value="1"/> </row> <row stringID="row" value="91"> <item label="Pin
Number" sort="smart" stringID="Pin_Number" value="F1"/> <item label="Pin
Usage" stringID="Pin_Usage" value="DIFFM"/> <item label="Pin
Name" sort="smart" stringID="Pin_Name" value="IO_L05P_3"/> <item stringID="Direction" value="UNUSED"/> <item label="IO Bank
Number" stringID="IO_Bank_Number" value="3"/> </row> <row stringID="row" value="92"> <item label="Pin
Number" sort="smart" stringID="Pin_Number" value="F2"/> <item label="Pin
Usage" stringID="Pin_Usage" value="DIFFS"/> <item label="Pin
Name" sort="smart" stringID="Pin_Name" value="IO_L05N_3"/> <item stringID="Direction" value="UNUSED"/> <item label="IO Bank
Number" stringID="IO_Bank_Number" value="3"/> </row> <row stringID="row" value="93"> <item label="Pin
Number" sort="smart" stringID="Pin_Number" value="F3"/> <item label="Pin
Name" sort="smart" stringID="Pin_Name" value="VCCO_3"/> <item label="IO Bank
Number" stringID="IO_Bank_Number" value="3"/> <item label="Voltage" stringID="Voltage" value="any******"/> </row> <row stringID="row" value="94"> <item label="Pin
Number" sort="smart" stringID="Pin_Number" value="F4"/> <item label="Pin
Usage" stringID="Pin_Usage" value="IOB"/> <item label="Pin
Name" sort="smart" stringID="Pin_Name" value="IO"/> <item stringID="Direction" value="UNUSED"/> <item label="IO Bank
Number" stringID="IO_Bank_Number" value="3"/> </row> <row stringID="row" value="95"> <item label="Pin
Number" sort="smart" stringID="Pin_Number" value="F5"/> <item label="Pin
Usage" stringID="Pin_Usage" value="IBUF"/> <item label="Pin
Name" sort="smart" stringID="Pin_Name" value="IP"/> <item stringID="Direction" value="UNUSED"/> <item label="IO Bank
Number" stringID="IO_Bank_Number" value="3"/> </row> <row stringID="row" value="96"> <item label="Pin
Number" sort="smart" stringID="Pin_Number" value="F6"/> <item label="Pin
Name" sort="smart" stringID="Pin_Name" value="VCCINT"/> <item label="Voltage" stringID="Voltage" value="1.2"/> </row> <row stringID="row" value="97"> <item label="Pin
Number" sort="smart" stringID="Pin_Number" value="F7"/> <item label="Pin
Usage" stringID="Pin_Usage" value="DIFFM"/> <item label="Pin
Name" sort="smart" stringID="Pin_Name" value="IO_L19P_0"/> <item stringID="Direction" value="UNUSED"/>
⌨️ 快捷键说明
复制代码
Ctrl + C
搜索代码
Ctrl + F
全屏模式
F11
切换主题
Ctrl + Shift + D
显示快捷键
?
增大字号
Ctrl + =
减小字号
Ctrl + -