impact.log

来自「xilinx xc9572 cpld 实现的伺服电机控制器」· LOG 代码 · 共 75 行

LOG
75
字号
iMPACT Version: G.35
iMPACT log file Started on 2006/04/25 16:32:56
// *** BATCH CMD : setPreference -pref UserLevel:NOVICE
// *** BATCH CMD : setPreference -pref MessageLevel:DETAILED
// *** BATCH CMD : setPreference -pref ConcurrentMode:FALSE
// *** BATCH CMD : setPreference -pref UseHighz:FALSE
// *** BATCH CMD : setPreference -pref ConfigOnFailure:STOP
// *** BATCH CMD : setPreference -pref StartupCLock:AUTO_CORRECTION
// *** BATCH CMD : setPreference -pref AutoSignature:FALSE
// *** BATCH CMD : setPreference -pref KeepSVF:FALSE
// *** BATCH CMD : setPreference -pref svfUseTime:FALSE
// *** BATCH CMD : setPreference -pref UserLevel:NOVICE
// *** BATCH CMD : setPreference -pref MessageLevel:DETAILED
// *** BATCH CMD : setPreference -pref ConcurrentMode:FALSE
// *** BATCH CMD : setPreference -pref UseHighz:FALSE
// *** BATCH CMD : setPreference -pref ConfigOnFailure:STOP
// *** BATCH CMD : setPreference -pref StartupCLock:AUTO_CORRECTION
// *** BATCH CMD : setPreference -pref AutoSignature:FALSE
// *** BATCH CMD : setPreference -pref KeepSVF:FALSE
// *** BATCH CMD : setPreference -pref svfUseTime:FALSE
GUI --- Boundary-Scan Mode selected
// *** BATCH CMD : setMode -bs
GUI --- Auto connect to cable...
// *** BATCH CMD : setCable -port auto
AutoDetecting cable. Please wait.
CB_PROGRESS_START - Starting Operation.
Connecting to cable (USB Port).
Cable connection failed.
Connecting to cable (Parallel Port - LPT1).
Checking cable driver.
 Driver windrvr6.sys version = 6.2.2.2. LPT base address = 0378h.
 ECP base address = 0778h.
Cable connection established.
CB_PROGRESS_END - End Operation.
Elapsed time =      1 sec.
// *** BATCH CMD : Identify
PROGRESS_START - Starting Operation.
Identifying chain contents ....'1': : Manufacturer's ID =Xilinx xc9572, Version : 2
INFO:iMPACT:1777 - 
Reading D:/Xilinx/xc9500/data/xc9572.bsd...
Reading D:/Xilinx/xc9500/data/xc9572.bsd...
INFO:iMPACT:501 - '1': Added Device xc9572 successfully.
----------------------------------------------------------------------
----------------------------------------------------------------------
done.
PROGRESS_END - End Operation.
Elapsed time =      0 sec.
// *** BATCH CMD : Erase -p 1 
PROGRESS_START - Starting Operation.
Validating chain...
Boundary-scan chain validated successfully.
'1': Putting device in ISP mode...done
'1': Erasing device...
done.
'1': Erasure completed successfully.
PROGRESS_END - End Operation.
Elapsed time =      7 sec.
// *** BATCH CMD : BlankCheck -p 1 
PROGRESS_START - Starting Operation.
Validating chain...
Boundary-scan chain validated successfully.
'1': Putting device in ISP mode...done
'1': Putting device in ISP mode...done
'1': Performing blank check on device...
'1': Blank check completed successfully.
'1': Device is blank.
PROGRESS_END - End Operation.
Elapsed time =      2 sec.
// *** BATCH CMD : ReadIdcode -p 1 
Validating chain...
Boundary-scan chain validated successfully.
'1': IDCODE is '00101001010100000100000010010011'
'1': IDCODE is '29504093' (in hex).
'1': : Manufacturer's ID =Xilinx xc9572, Version : 2