📄 onlinedll.bas
字号:
Attribute VB_Name = "Module1"
'
'It is assumed that you have installed
'Online Comm Manager in the folder of
'C:\OnlineCommManager
'
'Otherwise, you have to
'
'1. Copy OnlineDll.Dll to Windows or Windows\System folder,
' and remove the path specification
'or
'
'2. Copy OnlineDll.Dll to the same folder of your Exe file,
' and remove the path specification
'
'or
'
'3. Manual modify the path in
' Lib "C:\OnlineCommManager\OnlineDll.Dll"
Const CmdOK As Integer = 1
Const CmdEOT As Integer = 2
Const CmdEOF As Integer = 3
Const CmdACK As Integer = 4
Const CmdNAK As Integer = 5
Const CmdYES As Integer = 6
Const CmdNO As Integer = 7
Const CmdUSE As Integer = 8
Const CmdNONE As Integer = 9
Const CmdErr As Integer = 128
Const CmdErrLen As Integer = 129
Const CmdErrTime As Integer = 130
Const CmdErrSocket As Integer = 131
Const M_UNKNOWN As Integer = 0
Const M_OK As Integer = 1
Const M_CONNECT As Integer = 2
Const M_RING As Integer = 3
Const M_NOCARRIER As Integer = 4
Const M_ERROR As Integer = 5
Const M_NODIALTONE As Integer = 6
Const M_BUSY As Integer = 7
Const M_NOANSWER As Integer = 8
Const M_CARRIER As Integer = 9
'for ESC B Command
Type BARCFG
code39 As Byte
' "N" = Enable barcode decoding of Code 39
' "F" = Disable barcode decoding of Code 39
i2of5 As Byte
' "N" = Enable barcode decoding of Interleaved 2 of 5
' "F' = Disable barcode decoding of Interleaved 2 of 5
codabar As Byte
' "N" = Enable barcode decoding of CODABAR
' "F" = Disable barcode decoding of CODABAR
ean_upc As Byte
' "N" = Enable barcode decoding of UPC/EAN
' "F" = Disable barcode decoding of UPC/EAN
code128 As Byte
' "N" = Enable barcode decoding of Code 128
' "F" = Disable barcode decoding of Code 128
ean128 As Byte
' "N" = Enable barcode decoding of EAN 128
' "F" = Enable barcode decoding of EAN 128
code93 As Byte
' "N" = Enable barcode decoding of Code 93
' "F" = Disable barcode decoding of Code 93
End Type
'for PT500 only
Type BARCFG5
code39 As Byte
' "N" = Enable barcode decoding of Code 39
' "a".."h"
' "F" = Disable barcode decoding of Code 39
i2of5 As Byte
' "N" = Enable barcode decoding of Interleaved 2 of 5
' "a".."h"
' "F' = Disable barcode decoding of Interleaved 2 of 5
codabar As Byte
' "N" = Enable barcode decoding of CODABAR
' "a".."h"
' "F" = Disable barcode decoding of CODABAR
ean_upc As Byte
' "N" = Enable barcode decoding of UPC/EAN
' "F" = Disable barcode decoding of UPC/EAN
code128 As Byte
' "N" = Enable barcode decoding of Code 128
' "F" = Disable barcode decoding of Code 128
ean128 As Byte
' "N" = Enable barcode decoding of EAN 128
' msi, "a".."c"
' "F" = Enable barcode decoding of EAN 128
code93 As Byte
' "N" = Enable barcode decoding of Code 93
' "F" = Disable barcode decoding of Code 93
code32 As Byte
' "N" = Enable barcode decoding of Code 32
' "a".."d"
' "F" = Disable barcode decoding of Code 32
chnpost As Byte
' "N" = Enable barcode decoding of China postal code
' "a".."h"
' "F' = Disable barcode decoding of China postal code
End Type
'for PT600 only
Type BARCFG6
code39 As Byte
' "E" = Enable barcode decoding of Code 39
' "F" = Enable barcode decoding of Code 39, Full ASCII
' "D" = Disable barcode decoding of Code 39
i2of5 As Byte
' "E" = Enable barcode decoding of Interleaved 2 of 5
' "D' = Disable barcode decoding of Interleaved 2 of 5
codabar As Byte
' "E" = Enable barcode decoding of CODABAR
' "D" = Disable barcode decoding of CODABAR
ean_upc As Byte
' "E" = Enable barcode decoding of UPC/EAN
' "D" = Disable barcode decoding of UPC/EAN
code128 As Byte
' "E" = Enable barcode decoding of Code 128
' "D" = Disable barcode decoding of Code 128
ean128 As Byte
' "E" = Enable barcode decoding of EAN 128
' "D" = Enable barcode decoding of EAN 128
code93 As Byte
' "E" = Enable barcode decoding of Code 93
' "D" = Disable barcode decoding of Code 93
End Type
'for ESC C Command
'Always set "M" to Protocol,
'"04" to TimeOut, and "C" to FlowCtrl.
Type COMCFG
BaudRate As Byte
' "0" = 110 bps
' "1" = 150
' "2" = 300
' "3" = 600
' "4" = 1200
' "5" = 2400
' "6" = 4800
' "7" = 9600
' "8" = 19200
' "9" = 38400
' "A" = 57600
StopBits As Byte
' "1" = 1 Stop Bit
' "2" = 2 Stop Bits
DataBits As Byte
' "7" = 7 Data Bits
' "8" = 8 Data Bits
Parity As Byte
' "N" = None Parity
' "O" = Odd Parity
' "E" = Even Parity
Protocol As Byte
' "M" = Multi-point protocol
' "F" = None protocol
Address As Byte
' "A".."Y", or "0".."6"
Timeout(1) As Byte
' "00" = reserved
FlowCtrl As Byte
' "N" = None
' "X" = Xon/Xoff
' "C" = CTS/RTS (effect with RS232 only)
End Type
'for PT600 only
Type COMCFG6
BaudRate As Byte
' "0" = 110 bps
' "1" = 150
' "2" = 300
' "3" = 600
' "4" = 1200
' "5" = 2400
' "6" = 4800
' "7" = 9600
' "8" = 19200
' "9" = 38400
' "A" = 57600
StopBits As Byte
' "1" = 1 Stop Bit
' "2" = 2 Stop Bits
DataBits As Byte
' "7" = 7 Data Bits
' "8" = 8 Data Bits
Parity As Byte
' "N" = None Parity
' "O" = Odd Parity
' "E" = Even Parity
FlowCtrl As Byte
' "N" = None
' "X" = Xon/Xoff
' "C" = CTS/RTS
Protocol As Byte
' "M" = Multi-point protocol
' "F" = None protocol
Address As Byte
' "A".."Y", or "0".."6"
Timeout(2) As Byte
' "000" = reserved
End Type
'for ESC T Command
'ID is always 8 characters. So Pad space(s) character to ID
' if its length is less than 8.
Type TRMCFG
ID(7) As Byte
Online As Byte
' "R" = Remote. Transmit the data to host port.
' "L" = Local. No transmit.
Echo As Byte
' "N" = Display data on LCD.
' "F" = No Display.
AutoLF As Byte
' "N" = Append a LF with Data.
' "F" = No Append.
Mode As Byte
' "C" = Set to Character Mode. Transmit the data
' to the host port one character each time.
' "B" = Set to Block Mode. Transmit the data
' to the host port one block each time.
Block As Byte
' "L" = Set to line block mode.
' "P" = Set to page block mode.
' "B" = Set to both line and page block modes.
Line As Byte
' Line = end of line character.
Page As Byte
' Page = end of page character.
End Type
'for ESC V Command
'for MR320 Only
Type DEVCFG2
Scanner As Byte
' "A" = Auto Scanner
Badge As Byte
' "B" = Slot Reader
LCDBkLt As Byte
' "N" = On
' "F" = Off
Buzzer As Byte
' "N" = On
BuzzerVol As Byte
' "0".."7", "7" = Off
Interval As Byte
' "N" = On
' "F" = Off
Reserved(1) As Byte
' "00" Reserved
End Type
'for MR350 Only
Type DEVCFG5
Scanner As Byte
' "N" = reserved.
Badge As Byte
' "B" = Enable the badge.
' "D" = Disable the badge.
LCDBkLt As Byte
' "N" = reserved.
Buzzer As Byte
' "N" = Set buzzer on.
' "F" = Set Buzzer off.
KeyLock As Byte
' "N" = Set keyboard unlocked.
' "K" = Set keyboard locked.
' "P" = Set keyboard partial locked.
BuzzerVol As Byte
' "0" = Low volumn.
' "5" = Mid volumn.
' "9" = Hi volumn.
End Type
'for MR380 Only
Type DEVCFG8
Ext_Scanner As Byte
' "P" = Pen.
' "A" = Auto
' "M" = MSR
' "D" = Disable
Int_Scanner As Byte
' "B" = Bar code
' "M" = MSR
' "D" = Disable
LCDBkLt As Byte
' "N" = On
' "F" = Off
Buzzer As Byte
' "N" = Set buzzer on.
' "F" = Set Buzzer off.
KeyLock As Byte
' "N" = Set keyboard unlocked.
' "K" = Set keyboard locked.
' "P" = Set keyboard partial locked.
BuzzerVol As Byte
' "0" = Low volumn.
' "5" = Mid volumn.
' "9" = Hi volumn.
End Type
'for PT600 Only
Type DEVCFG6
Scanner As Byte
' "P" = Pen
' "A" = Auto
' "D" = Disable
LCDBkLt As Byte
' "N" = reserved.
Buzzer As Byte
' "N" = Set buzzer on.
' "F" = Set Buzzer off.
KeyLock As Byte
' "N" = reserved
BuzzerVol As Byte
' "0" = Low volumn.
' "5" = Mid volumn.
' "9" = Hi volumn.
End Type
Declare Function Online_Create _
Lib "C:\OnlineCommManager\OnlineDll.Dll" _
() As Long
Declare Function Online_Alloc _
Lib "C:\OnlineCommManager\OnlineDll.Dll" _
(ByRef HGlobal As Long) As Long
Declare Function Online_Init _
Lib "C:\OnlineCommManager\OnlineDll.Dll" _
(ByVal CommData As Long) As Integer
Declare Sub Online_Destroy _
Lib "C:\OnlineCommManager\OnlineDll.Dll" _
(ByVal CommData As Long)
Declare Sub Online_Done _
Lib "C:\OnlineCommManager\OnlineDll.Dll" _
(ByVal CommData As Long)
Declare Sub Online_Release _
Lib "C:\OnlineCommManager\OnlineDll.Dll" _
(ByRef HGlobal As Long)
Declare Function Online_Connect _
Lib "C:\OnlineCommManager\OnlineDll.Dll" _
(ByVal CommData As Long) As Integer
Declare Sub Online_Disconnect _
Lib "C:\OnlineCommManager\OnlineDll.Dll" _
(ByVal CommData As Long)
Declare Sub Online_Delay _
Lib "C:\OnlineCommManager\OnlineDll.Dll" _
(ByVal CommData As Long, _
ByVal Delay As Long)
Declare Function Online_SetupEx _
Lib "C:\OnlineCommManager\OnlineDll.Dll" _
(ByVal CommData As Long, _
ByVal Port As Integer, _
ByVal BaudRate As Integer, _
ByVal StopBits As Integer, _
ByVal Parity As Integer) As Integer
Declare Function Online_Setup _
Lib "C:\OnlineCommManager\OnlineDll.Dll" _
(ByVal CommData As Long, _
ByVal Port As Integer, _
ByVal BaudRate As Integer, _
ByVal StopBits As Integer, _