rfc2063.txt
来自「RFC 的详细文档!」· 文本 代码 · 共 1,449 行 · 第 1/5 页
TXT
1,449 行
If there are no more rules in the rule set, return from the
match() function indicating failure.
If the test indicator is off, or the test (above) succeeded:
Set the test indicator to this rule's test flag value.
Determine the next rule to execute.
If the opcode has its goto flag set, its parameter value
specifies the number of the next rule.
Opcodes which don't have their goto flags set either
determine the next rule in special ways (Return),
or they terminate execution (Ignore, Fail, Count,
CountPkt).
Perform the action.
Brownlee, et. al. Experimental [Page 21]
RFC 2063 Traffic Flow Measurement: Architecture January 1997
The PME maintains two 'history' data structures. The first, the
'return' stack, simply records the index (i.e. 1-origin rule number)
of each Gosub rule as it is executed; Return rules pop their Gosub
rule index. The second, the 'pattern' queue, is used to save
information for later use in building a flow key. A flow key is
built by zeroing all its attribute values, then copying attribute and
mask information from the pattern stack in the order it was enqueued.
The opcodes are:
opcode goto test
1 Ignore 0 -
2 Fail 0 -
3 Count 0 -
4 CountPkt 0 -
5 Return 0 0
6 Gosub 1 1
7 GosubAct 1 0
8 Assign 1 1
9 AssignAct 1 0
10 Goto 1 1
11 GotoAct 1 0
12 PushRuleTo 1 1
13 PushRuleToAct 1 0
14 PushPktTo 1 1
15 PushPktToAct 1 0
The actions they perform are:
Ignore: Stop matching, return from the match() function
indicating that the packet is to be ignored.
Fail: Stop matching, return from the match() function
indicating failure.
Count: Stop matching. Save this rule's attribute name,
mask and value in the PME's pattern queue, then
construct a flow key for the flow to which this
this packet belongs. Return from the match()
function indicating success. The meter will use
the flow key to locate the flow record for this
packet's flow.
CountPkt: As for Count, except that the masked value from
the packet is saved in the PME's pattern queue
instead of the rule's value.
Brownlee, et. al. Experimental [Page 22]
RFC 2063 Traffic Flow Measurement: Architecture January 1997
Gosub: Call a rule-matching subroutine. Push the current
rule number on the PME's return stack, set the
test indicator then goto the specified rule.
GosubAct: Same as Gosub, except that the test indicator is
cleared before going to the specified rule.
Return: Return from a rule-matching subroutine. Pop the
number of the calling gosub rule from the PME's
'return' stack and add this rule's parameter value
to it to determine the 'target' rule. Clear the
test indicator then goto the target rule.
A subroutine call appears in a rule set as a Gosub
rule followed by a small group of following rules.
Since a Return action clears the test flag, the
action of one of these 'following' rules will be
executed; this allows the subroutine to return a
result (in addition to any information it may save
in the PME's pattern queue).
Assign: Set the attribute specified in this rule to the
value specified in this rule. Set the test
indicator then goto the specified rule.
AssignAct: Same as Assign, except that the test indicator
is cleared before going to the specified rule.
Goto: Set the test indicator then goto the
specified rule.
GotoAct: Clear the test indicator then goto the specified
rule.
PushRuleTo: Save this rule's attribute name, mask and value
in the PME's pattern queue. Set the test
indicator then goto the specified rule.
PushRuleToAct: Same as PushRuleTo, except that the test indicator
is cleared before going to the specified rule.
PushRuleTo actions may be used to save the value
and mask used in a test, or (if the test is not
performed) to save an arbitrary value and mask.
Brownlee, et. al. Experimental [Page 23]
RFC 2063 Traffic Flow Measurement: Architecture January 1997
PushPktTo: Save this rule's attribute name, mask, together
with the masked value from the packet, in the
PME's pattern queue. SET the test indicator then
goto the specified rule.
PushPktToAct: Same as PushPktTo, except that the test indicator
is cleared before going to the specified rule.
PushPktTo actions may be used to save a value from
the packet using a specified mask. The test in
PushPktTo rules will almost never be executed.
As well as the attributes applying directly to packets (such as
SourcePeerAddress, DestTransAddress, etc.) the PME implements
several further attribtes. These are:
Null: Tests performed on the Null attribute always succeed.
v1 .. v5: v1, v2, v3, v4 and v5 are 'meter variables.' They
provide a way to pass parameters into rule-matching
subroutines. Each may hold the name of a normal
attribute; its value is set by an Assign action.
When a meter variable appears as the attribute of a
rule, its value specifies the actual attribute to be
tested. For example, if v1 had been assigned
SourcePeerAddress as its value, a rule with v1 as its
attribute would actually test SourcePeerAddress.
SourceClass, DestClass, FlowClass,
SourceKind, DestKind, FlowKind:
These six attributes may be set by executing PushRuleto
actions. They allow the PME to save (in flow records)
information which has been built up during matching.
Since their values are only defined when matching is
complete (and the flow key is built) their values may
not be tested in rules.
4.5 Maintaining the Flow Table
The flow table may be thought of as a 1-origin array of flow records.
(A particular implementation may, of course, use whatever data
structure is most suitable). When the meter starts up there are no
known flows; all the flow records are in the 'inactive' state.
Each time a packet is seen for a flow which is not in the current
flow set a flow record is set up for it; the state of such a record
is 'current.' When selecting a record for the new flow the meter
searches the flow table for a 'inactive' record - there is no
Brownlee, et. al. Experimental [Page 24]
RFC 2063 Traffic Flow Measurement: Architecture January 1997
particular significance in the ordering of records within the table.
Flow data may be collected by a 'meter reader' at any time. There is
no requirement for collections to be synchronized. The reader may
collect the data in any suitable manner, for example it could upload
a copy of the whole flow table using a file transfer protocol, or it
could read the records in the current flow set row by row using a
suitable data transfer protocol.
The meter keeps information about collections, in particular it
maintains a LastCollectTime variable which remembers the time the
last collection was made. A second variable, InactivityTime,
specifies the minimum time the meter will wait before considering
that a flow is idle.
The meter must recover records used for idle flows, if only to
prevent it running out of flow records. Recovered flow records are
returned to the 'inactive' state. A variety of recovery strategies
are possible, including the following:
One possible recovery strategy is to recover idle flow records as
soon as possible after their data has been collected. To implement
this the meter could run a background process which scans the flow
table looking for 'current' flows whose 'last packet' time is earlier
than the meter's LastCollectTime. This would be suitable for use
when one was interested in measuring flow lifetimes.
Another recovery strategy is to leave idle flows alone as long as
possible, which would be suitable if one was only interested in
measuring total traffic volumes. It could be implemented by having
the meter search for collected idle flows only when it ran out of
'inactive' flow records.
One further factor a meter should consider before recovering a flow
is the number of meter readers which have collected the flow's data.
If there are multiple meter readers operating, network Operations
personnel should be able to specify the minimum number of meters - or
perhaps a specific list of meters - which should collect a flow's
data before its memory can be recovered. This issue will be further
developed in the future.
4.6 Handling Increasing Traffic Levels
Under normal conditions the meter reader specifies which set of usage
records it wants to collect, and the meter provides them.
If memory usage rises above the high-water mark the meter should
switch to a STANDBY RULE SET so as to increase the granularity of
Brownlee, et. al. Experimental [Page 25]
RFC 2063 Traffic Flow Measurement: Architecture January 1997
flow collection and decrease the rate at which new flows are created.
When the manager, usually as part of a regular poll, becomes aware
that the meter is using its standby rule set, it could decrease the
interval between collections. The meter should also increase its
efforts to recover flow memory so as to reduce the number of idle
flows in memory. When the situation returns to normal, the manager
may request the meter to switch back to its normal rule set.
5 Meter Readers
Usage data is accumulated by a meter (e.g. in a router) as memory
permits. It is collected at regular reporting intervals by meter
readers, as specified by a manager. The collected data is recorded
in a disk file called a FLOW DATA FILE, as a sequence of USAGE
RECORDS.
The following sections describe the contents of usage records and
flow data files. Note, however, that at this stage the details of
such records and files is not specified in the architecture.
Specifying a common format for them would be a worthwhile future
development.
5.1 Identifying Flows in Flow Records
Once a packet has been classified and is ready to be counted, an
appropriate flow data record must already exist in the flow table;
otherwise one must be created. The flow record has a flexible format
where unnecessary identification attributes may be omitted. The
determination of which attributes of the flow record to use, and of
what values to put in them, is specified by the current rule set.
Note that the combination of start time, rule set id and subscript
(row number in the flow table) provide a unique flow identifier,
regardless of the values of its other attributes.
The current rule set may specify additional information, e.g. a
computed attribute value such as FlowKind, which is to be placed in
the attribute section of the usage record. That is, if a particular
flow is matched by the rule set, then the corresponding flow record
should be marked not only with the qualifying identification
attributes, but also with the additional information. Using this
feature, several flows may each carry the same FlowKind value, so
that the resulting usage records can be used in post-proc
⌨️ 快捷键说明
复制代码Ctrl + C
搜索代码Ctrl + F
全屏模式F11
增大字号Ctrl + =
减小字号Ctrl + -
显示快捷键?