rfc2063.txt
来自「RFC 的详细文档!」· 文本 代码 · 共 1,449 行 · 第 1/5 页
TXT
1,449 行
- TRAFFIC FLOW MATRICES, showing the total flow rates for
many of the possible paths within an internet.
- FLOW RATE FREQUENCY DISTRIBUTIONS, indicating how flow
rates vary with time.
- USAGE DATA showing the total traffic volumes sent and
received by particular hosts.
The operation of the traffic measurement system as a whole is best
understood by considering the interactions between its components.
These are described in the following sections.
2.2 Interaction Between METER and METER READER
The information which travels along this path is the usage data
itself. A meter holds usage data in an array of flow data records
known as the FLOW TABLE. A meter reader may collect the data in any
suitable manner. For example it might upload a copy of the whole
flow table using a file transfer protocol, or read the records in the
current flow set one at a time using a suitable data transfer
protocol. Note that the meter reader need not read complete flow
data records, a subset of their attribute values may well be
sufficient.
A meter reader may collect usage data from one or more meters. Data
may be collected from the meters at any time. There is no
requirement for collections to be synchronized in any way.
2.3 Interaction Between MANAGER and METER
A manager is responsible for configuring and controlling one or more
meters. At the time of writing a meter can only be controlled by a
single manager; in the future this restriction may be relaxed. Each
meter's configuration includes information such as:
- Flow specifications, e.g. which traffic flows are to be measured,
how they are to be aggregated, and any data the meter is required
to compute for each flow being measured.
- Meter control parameters, e.g. the maximum size of its flow table,
the 'inactivity' time for flows (if no packets belonging to a flow
are seen for this time the flow is considered to have ended, i.e.
to have become idle).
Brownlee, et. al. Experimental [Page 6]
RFC 2063 Traffic Flow Measurement: Architecture January 1997
- Sampling rate. Normally every packet will be observed. It may
sometimes be necessary to use sampling techniques to observe only
some of the packets. (Sampling algorithms are not prescribed by
the architecture; it should be noted that before using sampling one
should verify the statistical validity of the algorithm used).
Current experience with the measurement architecture shows that a
carefully-designed and implemented meter compresses the data such
that in normal LANs and WANs of today sampling is really not
needed.
2.4 Interaction Between MANAGER and METER READER
A manager is responsible for configuring and controlling one or more
meter readers. A meter reader may only be controlled by a single
manager. A meter reader needs to know at least the following for
every meter is is collecting usage data from:
- The meter's unique identity, i.e. its network name or address.
- How often usage data is to be collected from the meter.
- Which flow records are to be collected (e.g. all active flows, the
whole flow table, flows seen since a given time, etc.).
- Which attribute values are to be collected for the required flow
records (e.g. all attributes, or a small subset of them)
Since redundant reporting may be used in order to increase the
reliability of usage data, exchanges among multiple entities must be
considered as well. These are discussed below.
2.5 Multiple METERs or METER READERs
-- METER READER A --
/ | \
/ | \
=====METER 1 METER 2=====METER 3 METER 4=====
\ | /
\ | /
-- METER READER B --
Several uniquely identified meters may report to one or more meter
readers. The diagram above gives an example of how multiple meters
and meter readers could be used.
Brownlee, et. al. Experimental [Page 7]
RFC 2063 Traffic Flow Measurement: Architecture January 1997
In the diagram above meter 1 is read by meter reader A, and meter 4
is read by meter reader B. Meters 1 and 4 have no redundancy; if
either fails, usage data for their network segments will be lost.
Meters 2 and 3, however, measure traffic on the same network segment.
One of them may fail leaving the other collecting the segment's usage
data. Meters 2 and 3 are read by meter reader A and by meter reader
B. If one meter reader fails, the other will continue collecting
usage data.
The architecture does not require multiple meter readers to be
synchronized. In the situation above meter readers A and B could
both collect usage data at the same intervals, but not neccesarily at
the same times. Note that because collections are asynchronous it is
unlikely that usage records from two different meter readers will
agree exactly.
If precisely synchronized collections are required this can be
achieved by having one manager request each meter to begin collecting
a new set of flows, then allowing all meter readers to collect the
usage data from the old sets of flows.
If there is only one meter reader and it fails, the meters continue
to run. When the meter reader is restarted it can collect all of the
accumulated flow data. Should this happen, time resolution will be
lost (because of the missed collections) but overall traffic flow
information will not. The only exception to this would occur if the
traffic volume was sufficient to 'roll over' counters for some flows
during the failure; this is addressed in the section on 'Rolling
Counters.'
2.6 Interaction Between MANAGERs (MANAGER - MANAGER)
Synchronization between multiple management systems is the province
of network management protocols. This traffic flow measurement
architecture specifies only the network management controls necessary
to perform the traffic flow measurement function and does not address
the more global issues of simultaneous or interleaved (possibly
conflicting) commands from multiple network management stations or
the process of transferring control from one network management
station to another.
2.7 METER READERs and APPLICATIONs
Once a collection of usage data has been assembled by a meter reader
it can be processed by an analysis application. Details of analysis
applications - such as the reports they produce and the data they
require - are outside the scope of this architecture.
Brownlee, et. al. Experimental [Page 8]
RFC 2063 Traffic Flow Measurement: Architecture January 1997
It should be noted, however, that analysis applications will often
require considerable amounts of input data. An important part of
running a traffic flow measurement system is the storage and regular
reduction of flow data so as to produce daily, weekly or monthly
summary files for further analysis. Again, details of such data
handling are outside the scope of this architecture.
3 Traffic Flows and Reporting Granularity
A flow was defined in section 2.1 above in abstract terms as follows:
"A TRAFFIC FLOW is an artifical logical equivalent to a call or
connection, belonging to an ACCOUNTABLE ENTITY."
In practical terms, a flow is a stream of packets passing across a
network between two end points (or being sent from a single end
point), which have been summarized by a traffic meter for analysis
purposes.
3.1 Flows and their Attributes
Every traffic meter maintains a table of 'flow records' for flows
seen by the meter. A flow record holds the values of the ATTRIBUTES
of interest for its flow. These attributes might include:
- ADDRESSES for the flow's source and destination. These comprise
the protocol type, the source and destination addresses at various
network layers (extracted from the packet), and the number of the
interface on which the packet was observed.
- First and last TIMES when packets were seen for this flow, i.e.
the 'creation' and 'last activity' times for the flow.
- COUNTS for 'forward' (source to destination) and 'backward'
(destination to source) components (e.g. packets and bytes) of the
flow's traffic. The specifying of 'source' and 'destination' for
flows is discussed in the section on packet matching below.
- OTHER attributes, e.g. information computed by the meter.
A flow's ACCOUNTABLE ENTITY is specified by the values of its ADDRESS
attributes. For example, if a flow's address attributes specified
only that "source address = IP address 10.1.0.1," then all IP packets
from and to that address would be counted in that flow. If a flow's
address list were specified as "source address = IP address 10.1.0.1,
destination address = IP address 26.1.0.1" then only IP packets
between 10.1.0.1 and 26.1.0.1 would be counted in that flow.
Brownlee, et. al. Experimental [Page 9]
RFC 2063 Traffic Flow Measurement: Architecture January 1997
The addresses specifying a flow's address attributes may include one
or more of the following types:
- The INTERFACE NUMBER for the flow, i.e. the interface on which the
meter measured the traffic. Together with a unique address for the
meter this uniquely identifies a particular physical-level port.
- The ADJACENT ADDRESS, i.e. the [n-1] layer address of the
immediate source or destination on the path of the packet. For
example, if flow measurement is being performed at the IP layer on
an Ethernet LAN [3], an adjacent address is a six-octet Media
Access Control (MAC) address. For a host connected to the same LAN
segment as the meter the adjacent address will be the MAC address
of that host. For hosts on other LAN segments it will be the MAC
address of the adjacent (upstream or downstream) router carrying
the traffic flow.
- The PEER ADDRESS, which identifies the source or destination of the
PEER-LEVEL packet. The form of a peer address will depend on the
network-layer protocol in use, and the network layer [n] at which
traffic measurement is being performed.
- The TRANSPORT ADDRESS, which identifies the source or destination
port for the packet, i.e. its [n+1] layer address. For example,
if flow measurement is being performed at the IP layer a transport
address is a two-octet UDP or TCP port number.
The four definitions above specify addresses for each of the four
lowest layers of the OSI reference model, i.e. Physical layer, Link
layer, Network layer and Transport layer. A FLOW RECORD stores both
the VALUE for each of its addresses (as described above) and a MASK
specifying which bits of the address value are being used and which
are ignored. Note that if address bits are being ignored the meter
will set them to zero, however their actual values are undefined.
One of the key features of the traffic measurement architecture is
that attributes have essentially the same meaning for different
protocols, so that analysis applications can use the same reporting
formats for all protocols. This is straightforward for peer
addresses; although the form of addresses differs for the various
protocols, the meaning of a 'peer address' remains the same. It
becomes harder to maintain this correspondence at higher layers - for
example, at the Network layer IP, Novell IPX and AppleTalk all use
port numbers as a 'transport address,' but CLNP and DECnet have no
notion of ports. Further work is needed here, particularly in
selecting attributes which will be suitable for the higher layers of
the OSI reference model.
Brownlee, et. al. Experimental [Page 10]
RFC 2063 Traffic Flow Measurement: Architecture January 1997
Reporting by adjacent intermediate sources and destinations or simply
by meter interface (most useful when the meter is embedded in a
router) supports hierarchical Internet reporting schemes as described
in the 'Traffic Flow Measurement: Background' RFC [1]. That is, it
allows backbone and regional networks to measure usage to just the
next lower level of granularity (i.e. to the regional and
stub/enterprise levels, respectively), with the final breakdown
according to end user (e.g. to source IP address) performed by the
stub/enterprise networks.
In cases where network addresses are dynamically allocated (e.g.
mobile subscribers), further subscriber identification will be
necessary if flows are to ascribed to individual users. Provision is
made to further specify the accountable entity through the use of an
⌨️ 快捷键说明
复制代码Ctrl + C
搜索代码Ctrl + F
全屏模式F11
增大字号Ctrl + =
减小字号Ctrl + -
显示快捷键?