rfc2108.txt

来自「RFC 的详细文档!」· 文本 代码 · 共 1,751 行 · 第 1/5 页

TXT
1,751 行
字号


               deprecated in this MIB.  It is recommended
               that management applications instead use
               the repeater-level counters contained in
               the rptrMonTable."
       INDEX    { rptrMonitorGroupIndex }
       ::= { rptrMonitorGroupTable 1 }

   RptrMonitorGroupEntry ::=
       SEQUENCE {
           rptrMonitorGroupIndex
               Integer32,
           rptrMonitorGroupTotalFrames
               Counter32,
           rptrMonitorGroupTotalOctets
               Counter32,
           rptrMonitorGroupTotalErrors
               Counter32
       }

   rptrMonitorGroupIndex OBJECT-TYPE
       SYNTAX      Integer32 (1..2147483647)
       MAX-ACCESS  read-only
       STATUS      deprecated
       DESCRIPTION
               "********* THIS OBJECT IS DEPRECATED **********

               This object identifies the group within the
               repeater for which this entry contains
               information."
       ::= { rptrMonitorGroupEntry 1 }

   rptrMonitorGroupTotalFrames OBJECT-TYPE
       SYNTAX      Counter32
       MAX-ACCESS  read-only
       STATUS      deprecated
       DESCRIPTION
               "********* THIS OBJECT IS DEPRECATED **********

               The total number of frames of valid frame length
               that have been received on the ports in this group
               and for which the FCSError and CollisionEvent
               signals were not asserted.  This counter is the
               summation of the values of the
               rptrMonitorPortReadableFrames counters for all of
               the ports in the group.

               This statistic provides one of the parameters
               necessary for obtaining the packet error rate.



de Graaf, et. al.           Standards Track                    [Page 26]

RFC 2108             802.3 Repeater MIB using SMIv2        February 1997


               The approximate minimum time for rollover of this
               counter is 80 hours in a 10Mb/s repeater."
       ::= { rptrMonitorGroupEntry 2 }

   rptrMonitorGroupTotalOctets OBJECT-TYPE
       SYNTAX      Counter32
       MAX-ACCESS  read-only
       STATUS      deprecated
       DESCRIPTION
               "********* THIS OBJECT IS DEPRECATED **********

               The total number of octets contained in the valid
               frames that have been received on the ports in
               this group.  This counter is the summation of the
               values of the rptrMonitorPortReadableOctets
               counters for all of the ports in the group.

               This statistic provides an indicator of the total
               data transferred.  The approximate minimum time
               for rollover of this counter is 58 minutes in a
               10Mb/s repeater."
       ::= { rptrMonitorGroupEntry 3 }

   rptrMonitorGroupTotalErrors OBJECT-TYPE
       SYNTAX      Counter32
       MAX-ACCESS  read-only
       STATUS      deprecated
       DESCRIPTION
               "********* THIS OBJECT IS DEPRECATED **********

               The total number of errors which have occurred on
               all of the ports in this group.  This counter is
               the summation of the values of the
               rptrMonitorPortTotalErrors counters for all of the
               ports in the group."
       ::= { rptrMonitorGroupEntry 4 }


   -- Statistics at the port level.
   --

   rptrMonitorPortTable OBJECT-TYPE
       SYNTAX      SEQUENCE OF RptrMonitorPortEntry
       MAX-ACCESS  not-accessible
       STATUS      current
       DESCRIPTION
               "Table of performance and error statistics for the
               ports.  The number of entries is the same as that



de Graaf, et. al.           Standards Track                    [Page 27]

RFC 2108             802.3 Repeater MIB using SMIv2        February 1997


               in the rptrPortTable.

               The columnar object rptrMonitorPortLastChange
               is used to indicate possible discontinuities
               of counter type columnar objects in the table."
       ::= { rptrMonitorPortInfo 1 }

   rptrMonitorPortEntry OBJECT-TYPE
       SYNTAX      RptrMonitorPortEntry
       MAX-ACCESS  not-accessible
       STATUS      current
       DESCRIPTION
               "An entry in the table, containing performance and
               error statistics for a single port."
       INDEX    { rptrMonitorPortGroupIndex, rptrMonitorPortIndex }
       ::= { rptrMonitorPortTable 1 }

   RptrMonitorPortEntry ::=
       SEQUENCE {
           rptrMonitorPortGroupIndex
               Integer32,
           rptrMonitorPortIndex
               Integer32,
           rptrMonitorPortReadableFrames
               Counter32,
           rptrMonitorPortReadableOctets
               Counter32,
           rptrMonitorPortFCSErrors
               Counter32,
           rptrMonitorPortAlignmentErrors
               Counter32,
           rptrMonitorPortFrameTooLongs
               Counter32,
           rptrMonitorPortShortEvents
               Counter32,
           rptrMonitorPortRunts
               Counter32,
           rptrMonitorPortCollisions
               Counter32,
           rptrMonitorPortLateEvents
               Counter32,
           rptrMonitorPortVeryLongEvents
               Counter32,
           rptrMonitorPortDataRateMismatches
               Counter32,
           rptrMonitorPortAutoPartitions
               Counter32,
           rptrMonitorPortTotalErrors



de Graaf, et. al.           Standards Track                    [Page 28]

RFC 2108             802.3 Repeater MIB using SMIv2        February 1997


               Counter32,
           rptrMonitorPortLastChange
               TimeStamp
       }

   rptrMonitorPortGroupIndex OBJECT-TYPE
       SYNTAX      Integer32 (1..2147483647)
       MAX-ACCESS  read-only
       STATUS      current
       DESCRIPTION
               "This object identifies the group containing the
               port for which this entry contains information."
       ::= { rptrMonitorPortEntry 1 }

   rptrMonitorPortIndex OBJECT-TYPE
       SYNTAX      Integer32 (1..2147483647)
       MAX-ACCESS  read-only
       STATUS      current
       DESCRIPTION
               "This object identifies the port within the group
               for which this entry contains information."
       REFERENCE
               "[IEEE 802.3 Mgt], 30.4.3.1.1, aPortID."
       ::= { rptrMonitorPortEntry 2 }

   rptrMonitorPortReadableFrames OBJECT-TYPE
       SYNTAX      Counter32
       MAX-ACCESS  read-only
       STATUS      current
       DESCRIPTION
               "This object is the number of frames of valid
               frame length that have been received on this port.
               This counter is incremented by one for each frame
               received on this port whose OctetCount is greater
               than or equal to minFrameSize and less than or
               equal to maxFrameSize (Ref: IEEE 802.3 Std,
               4.4.2.1) and for which the FCSError and
               CollisionEvent signals are not asserted.

               A discontinuity may occur in the value
               when the value of object
               rptrMonitorPortLastChange changes.

               This statistic provides one of the parameters
               necessary for obtaining the packet error rate.
               The approximate minimum time for rollover of this
               counter is 80 hours at 10Mb/s."
       REFERENCE



de Graaf, et. al.           Standards Track                    [Page 29]

RFC 2108             802.3 Repeater MIB using SMIv2        February 1997


               "[IEEE 802.3 Mgt], 30.4.3.1.4, aReadableFrames."
       ::= { rptrMonitorPortEntry 3 }

   rptrMonitorPortReadableOctets OBJECT-TYPE
       SYNTAX      Counter32
       MAX-ACCESS  read-only
       STATUS      current
       DESCRIPTION
               "This object is the number of octets contained in
               valid frames that have been received on this port.
               This counter is incremented by OctetCount for each
               frame received on this port which has been
               determined to be a readable frame (i.e., including
               FCS octets but excluding framing bits and dribble
               bits).

               A discontinuity may occur in the value
               when the value of object
               rptrMonitorPortLastChange changes.

               This statistic provides an indicator of the total
               data transferred.  The approximate minimum time
               for rollover of this counter in a 10Mb/s repeater
               is 58 minutes.

               For ports receiving traffic at a maximum rate in
               a 100Mb/s repeater, this counter can roll over
               in less than 6 minutes.  Since that amount of time
               could be less than a management station's poll cycle
               time, in order to avoid a loss of information a
               management station is advised to also poll the
               rptrMonitorPortUpper32Octets object, or to use the
               64-bit counter defined by
               rptrMonitorPortHCReadableOctets instead of the
               two 32-bit counters."
       REFERENCE
               "[IEEE 802.3 Mgt], 30.4.3.1.5, aReadableOctets."
       ::= { rptrMonitorPortEntry 4 }

   rptrMonitorPortFCSErrors OBJECT-TYPE
       SYNTAX      Counter32
       MAX-ACCESS  read-only
       STATUS      current
       DESCRIPTION
               "This counter is incremented by one for each frame
               received on this port with the FCSError signal
               asserted and the FramingError and CollisionEvent
               signals deasserted and whose OctetCount is greater



de Graaf, et. al.           Standards Track                    [Page 30]

RFC 2108             802.3 Repeater MIB using SMIv2        February 1997


               than or equal to minFrameSize and less than or
               equal to maxFrameSize (Ref: 4.4.2.1, IEEE 802.3
               Std).

               A discontinuity may occur in the value
               when the value of object
               rptrMonitorPortLastChange changes.

               The approximate minimum time for rollover of this
               counter is 80 hours at 10Mb/s."
       REFERENCE
               "[IEEE 802.3 Mgt], 30.4.3.1.6,
               aFrameCheckSequenceErrors."
       ::= { rptrMonitorPortEntry 5 }

   rptrMonitorPortAlignmentErrors OBJECT-TYPE
       SYNTAX      Counter32
       MAX-ACCESS  read-only
       STATUS      current
       DESCRIPTION
               "This counter is incremented by one for each frame
               received on this port with the FCSError and
               FramingError signals asserted and CollisionEvent
               signal deasserted and whose OctetCount is greater
               than or equal to minFrameSize and less than or
               equal to maxFrameSize (Ref: IEEE 802.3 Std,
               4.4.2.1).  If rptrMonitorPortAlignmentErrors is
               incremented then the rptrMonitorPortFCSErrors
               Counter shall not be incremented for the same
               frame.

               A discontinuity may occur in the value
               when the value of object
               rptrMonitorPortLastChange changes.

               The approximate minimum time for rollover of this
               counter is 80 hours at 10Mb/s."
       REFERENCE
               "[IEEE 802.3 Mgt], 30.4.3.1.7, aAlignmentErrors."
       ::= { rptrMonitorPortEntry 6 }

   rptrMonitorPortFrameTooLongs OBJECT-TYPE
       SYNTAX      Counter32
       MAX-ACCESS  read-only
       STATUS      current
       DESCRIPTION
               "This counter is incremented by one for each frame
               received on this port whose OctetCount is greater



de Graaf, et. al.           Standards Track                    [Page 31]

RFC 2108             802.3 Repeater MIB using SMIv2        February 1997


               than maxFrameSize (Ref: 4.4.2.1, IEEE 802.3 Std).
               If rptrMonitorPortFrameTooLongs is incremented
               then neither the rptrMonitorPortAlignmentErrors
               nor the rptrMonitorPortFCSErrors counter shall be
               incremented for the frame.

               A discontinuity may occur in the value
               when the value of object
               rptrMonitorPortLastChange 