⭐ 欢迎来到虫虫下载站! | 📦 资源下载 📁 资源专辑 ℹ️ 关于我们
⭐ 虫虫下载站

📄 telebit

📁 使用efax的fax工具程序
💻
字号:
From: sainez@Telebit.COM (Jaime Sainez)Subject: Re: Documentation for Telebit modems in FAX mode?Here's the Telebit T3000/WorldBlazer (Up to LA7.04c) commands in theirsimplest form.                             COMMAND DESCRIPTIONS+FAA, Answer Parameter+FAA=? 0+FAA=0 _______________________________________+FAXERR, T.30 Session Error Report+FAXERR=<table value>, read onlyValid values: 0-255   Mandatory values: 0,10,20,30,40,50,60,70_______________________________________+FBADLIN, Bad Line Threshold+FBADLIN=? 0+FBADLIN=0 _______________________________________+FBADMUL, Error Threshold Multiplier+FBADMUL=? 0+FBADMUL=0 ._______________________________________+FBOR, Data Bit Order+FBOR=? 0-3+FBOR=0 +FBOR=1 +FBOR=2 +FBOR=3 _______________________________________+FBUF, Buffer Size+FBUF=0 _______________________________________+FBUG, Session Message Reporting+FBUG=? 0,1+FBUG=0 +FBUG=1 _______________________________________+FCIG, Local Polling ID String+FCIG=? (20)(32-127)+FCIG="<local polling ID string>"_______________________________________+FCLASS, Service Class Identification & Selection+FCLASS=? 0,2+FCLASS=0 +FCLASS=2 _______________________________________+FCQ, Copy Quality Checking+FCQ=? 0+FCQ=0 _______________________________________+FCR, Capability to Receive+FCR=? 0,1+FCR=0 +FCR=1 _______________________________________+FCTCRTY, CTC Retry Count+FCTCRTY=? 0+FCTCRTY=0 _______________________________________+FDCC, DCE capabilities parameters+FDCC=<VR,BR,WD,LN,DF,EC,BF,ST>+FDCC=? (0,1),(0-3),(0-2),(0-2),(0),(0),(0),(0-7)+FDCC? 0,3,0,2,0,0,0,0 Default ValueValues:VR  0,1BR  0,1,2,3WD  0,1,2LN  0,1,2DF  0EC  0BF  0ST  0,1,2,3,4,5,6,7_______________________________________+FDCS, Current Session results+FDCS=<VR,BR,WD,LN,DF,EC,BF,ST>+FDCS? 0,0,0,0,0,0,0,0 Default value._______________________________________+FDFFC, Data Compression Format Conversion+FDFFC=? 0+FDFFC=0 _______________________________________+FDIS, Current Session Parameters+FDIS=<VR,BR,WD,LN,DF,EC,BF,ST>+FDIS=? (0,1),(0-3),(0-2),(0-2),(0),(0),(0),(0-7)+FDIS? 0,3,0,2,0,0,0,0 Default valueValues:VR  0,1BR  0,1,2,3WD  0,1,2LN  0,1,2DF  0EC  0BF  0ST  0,1,2,3,4,5,6,7_______________________________________+FDR, Begin or Continue Phase C Receive Data+FDR  _______________________________________+FDT, Data Transmission+FDT  _______________________________________+FECM, Error Correction Mode Control+FECM=? 0+FECM=0 _______________________________________+FET, Transmit Page Punctuation+FET=? 0,1,2,4,5,6Values:0  1  2  4  5  6  _______________________________________+FK, Session Termination+FK_______________________________________+FLID, Local ID String+FLID=? (20)(32-127)+FLID="local ID string"_______________________________________+FLNFC, Page Length Format Conversion+FLNFC=? 0+FLNFC=0 _______________________________________+FLPL, Indicate Document to Poll+FLPL=? 0,1+FLPL=0 +FLPL=1 _______________________________________+FMDL?, Request Model Identification+FMDL?_______________________________________+FMFR?, Request Manufacturer Identification+FMFR?response:Telebit_______________________________________+FMINSP, Minimum Phase C Speed+FMINSP=? 0-3+FMINSP=0 +FMINSP=1 +FMINSP=2 +FMINSP=3 _______________________________________+FPHCTO, DTE Phase C Response Time-out+FPHCTO=? 0-255+FPHCTO? 30 Default value.Range:0 - 255_______________________________________+FPTS, Page Transfer Status+FPTS=? 1-5+FPTS=1 +FPTS=2 +FPTS=3 +FPTS=4 +FPTS=5 _______________________________________+FRBC, Phase C Receive Data Block Size+FRBC=? 0-0+FRBC=0 _______________________________________+FREL, Phase C Received EOL Alignment+FREL=? 0,1+FREL=0 +FREL=1 _______________________________________+FREV?, Request Product Revision Identification+FREV?_______________________________________+FSPL, Request to Poll+FSPL=? 0,1+FSPL=0 +FSPL=1 _______________________________________+FTBC, Phase C Trasmit Data Block Size+FTBC=0 _______________________________________+FVRFC, Vertical Resolution Format Conversion+FVRFC=? 0+FVRFC=0 _______________________________________+FWDFC, Page Width Format Conversion+FWDFC=? 0+FWDFC=0                            RESPONSE DESCRIPTIONS_______________________________________+FCFR, Indicate Confirmation to Receive+FCFR _______________________________________+FCKG:<string>, Report the Remote ID+FCKG:"<CIG ID string>" Polling station ID+FCKG _______________________________________+FCON, Facsimile Connection Response+FCON _______________________________________+FCSI:<string>, Report the remote ID+FCSI:"<CSI ID string>"Called Station ID+FCSI _______________________________________+FDCS, Report DIS/DCS/DTC frame information+FDCS=<VR,BR,WD,LN,DF,EC,BF,ST>+FDCS? 0,0,0,0,0,0,0,0 Default value._______________________________________+FHNG, Call Termination with Status+FHNG:<hang-up status code>_______________________________________+FPOLL, Remote Polling Indication+FPOLL_______________________________________+FPTS, Receive and Transmit Page Transfer Status+FPTS=? 1-5+FPTS=1+FPTS=2+FPTS=3+FPTS=4+FPTS=5  _______________________________________+FTSI:<string>, Report the Remote ID+FTSI:"<TSI ID string>"Transmit Station ID

⌨️ 快捷键说明

复制代码 Ctrl + C
搜索代码 Ctrl + F
全屏模式 F11
切换主题 Ctrl + Shift + D
显示快捷键 ?
增大字号 Ctrl + =
减小字号 Ctrl + -