  • Cogeneration+and+District+Energy+Systems

    District energy (DE) systems use central heating and/or cooling facilities to provide heating and/or cooling services for communities. The advantages of district energy over conventional heating and cooling include improved efficiency, reliability and safety, reduced environmental impact, and for many situations better economics. DE systems can be particularly beneficial when integrated with cogeneration plants for electricity and heat, i.e., with combined heat and power (CHP) plants. One of the main impediments to increased use of cogeneration-based district energy is a lack of understanding of the behavior of integrated forms of such systems. This book is aimed at providing information on district energy and cogeneration tech- nologies, as well as systems that combine them.

    标签: Cogeneration District Systems Energy and

    上传时间: 2020-06-06

    上传用户:shancjb

  • Transmission+Line+Protection

    Modern power systems involve large amount of investment. An electric power system comprises of generation, transmission, and distribution of electric energy. Growth of power systems has led to very complex networks extended across large areas. In such situations, the proper functioning of a modern power system is heavily dependent upon the healthy operation of the transmission lines within it. Transmission lines are used to transmit a huge amount of power over a long distance. But as these lines are located in the open atmosphere, they are highly affected by different types of abnormal conditions or faults.

    标签: Transmission Protection Line

    上传时间: 2020-06-07

    上传用户:shancjb

  • Linear Optimal Control

    Despite the development of a now vast body of knowledge known as modern control theory, and despite some spectacular applications of this theory to practical situations, it is quite clear that much of the theory has yet to find application, and many practical control problems have yet to find a theory which will successfully deal with them. No book of course can remedy the situation at this time. But the aim of this book is to construct one of many bridges that are still required for the student and practicing control engineer between the familiar classical control results and those of modern control theory. 

    标签: Control Optimal Linear

    上传时间: 2020-06-09

    上传用户:shancjb

  • Optimal Control Linear Quadratic Methods

    Despite the development of a now vast body of knowledge known as modern control theory, and despite some spectacular applications of this theory to practical situations, it is quite clear that some of the theory has yet to find application, and many practical control problems have yet to find a theory that will successfully deal with them. No one book, of course, can remedy the situation. The aim of this book is to construct bridges that are still required for the student and practicing control engineer between the familiar classical control results and those of modern control theory.

    标签: Quadratic Optimal Control Methods Linear

    上传时间: 2020-06-09

    上传用户:shancjb

  • 电子书-RTL Design Style Guide for Verilog HDL540页

    电子书-RTL Design Style Guide for Verilog HDL540页A FF having a fixed input value is generated from the description in the upper portion of Example 2-21. In this case, ’0’ is output when the reset signal is asynchronously input, and ’1’ is output when the START signal rises. Therefore, the FF data input is fixed at the power supply, since the typical value ’1’ is output following the rise of the START signal. When FF input values are fixed, the fixed inputs become untestable and the fault detection rate drops. When implementing a scan design and converting to a scan FF, the scan may not be executed properl not be executed properly, so such descriptions , so such descriptions are not are not recommended. recommended.[1] As in the lower part of Example 2-21, be sure to construct a synchronous type of circuit and ensure that the clock signal is input to the clock pin of the FF. Other than the sample shown in Example 2-21, there are situations where for certain control signals, those that had been switched due to the conditions of an external input will no longer need to be switched, leaving only a FF. If logic exists in a lower level and a fixed value is input from an upper level, the input value of the FF may also end up being fixed as the result of optimization with logic synthesis tools. In a situation like this, while perhaps difficult to completely eliminate, the problem should be avoided as much as possible.

    标签: RTL verilog hdl

    上传时间: 2022-03-21