虫虫首页| 资源下载| 资源专辑| 精品软件
登录| 注册

revised

  • Clock based on the VHDL design language, the revised time alarm can be set up

    Clock based on the VHDL design language, the revised time alarm can be set up

    标签: the language revised design

    上传时间: 2013-12-09

    上传用户:haoxiyizhong

  • MPC7400 Part Number Speci&THOR

    MPC7400 Part Number SpeciÞcationThis document describes part number speciÞc changes to recommended operating conditions and revised electrical speciÞcations,as applicable, from those described in the generalMPC7400 Hardware SpeciÞcations.SpeciÞcations provided in this Part Number SpeciÞcation supersede those in theMPC7400 Hardware SpeciÞcationsdated 9/99(order #: MPC7400EC/D) for these part numbers only; speciÞcations not addressed herein are unchanged. This document isfrequently updated, refer to the website at http://www.mot.com/SPS/PowerPC/ for the latest version.Note that headings and table numbers in this data sheet are not consecutively numbered. They are intended to correspond to theheading or table affected in the general hardware speciÞcation.

    标签: Number Speci 7400 Part

    上传时间: 2014-12-28

    上传用户:huyahui

  • MPC7400l零件号码规范说明

    This document describes part number speciÞc changes to recommended operating conditions and revised electrical speciÞcations,as applicable, from those described in the generalMPC7400 Hardware SpeciÞcations.SpeciÞcations provided in this Part Number SpeciÞcation supersede those in theMPC7400 Hardware SpeciÞcationsdated 9/99(order #: MPC7400EC/D) for these part numbers only; speciÞcations not addressed herein are unchanged. This document isfrequently updated, refer to the website at http://www.mot.com/SPS/PowerPC/ for the latest version.Note that headings and table numbers in this data sheet are not consecutively numbered. They are intended to correspond to theheading or table affected in the general hardware speciÞcation.Part numbers addressed in this document are listed in Table A. For more detailed ordering information see Table B.

    标签: 7400l 7400 MPC 零件

    上传时间: 2013-11-19

    上传用户:qiaoyue

  • 采用TÜV认证的FPGA开发功能安全系统

    This white paper discusses how market trends, the need for increased productivity, and new legislation have accelerated the use of safety systems in industrial machinery. This TÜV-qualified FPGA design methodology is changing the paradigms of safety designs and will greatly reduce development effort, system complexity, and time to market. This allows FPGA users to design their own customized safety controllers and provides a significant competitive advantage over traditional microcontroller or ASIC-based designs. Introduction The basic motivation of deploying functional safety systems is to ensure safe operation as well as safe behavior in cases of failure. Examples of functional safety systems include train brakes, proximity sensors for hazardous areas around machines such as fast-moving robots, and distributed control systems in process automation equipment such as those used in petrochemical plants. The International Electrotechnical Commission’s standard, IEC 61508: “Functional safety of electrical/electronic/programmable electronic safety-related systems,” is understood as the standard for designing safety systems for electrical, electronic, and programmable electronic (E/E/PE) equipment. This standard was developed in the mid-1980s and has been revised several times to cover the technical advances in various industries. In addition, derivative standards have been developed for specific markets and applications that prescribe the particular requirements on functional safety systems in these industry applications. Example applications include process automation (IEC 61511), machine automation (IEC 62061), transportation (railway EN 50128), medical (IEC 62304), automotive (ISO 26262), power generation, distribution, and transportation. 图Figure 1. Local Safety System

    标签: FPGA 安全系统

    上传时间: 2013-11-05

    上传用户:维子哥哥

  • 采用TÜV认证的FPGA开发功能安全系统

    This white paper discusses how market trends, the need for increased productivity, and new legislation have accelerated the use of safety systems in industrial machinery. This TÜV-qualified FPGA design methodology is changing the paradigms of safety designs and will greatly reduce development effort, system complexity, and time to market. This allows FPGA users to design their own customized safety controllers and provides a significant competitive advantage over traditional microcontroller or ASIC-based designs. Introduction The basic motivation of deploying functional safety systems is to ensure safe operation as well as safe behavior in cases of failure. Examples of functional safety systems include train brakes, proximity sensors for hazardous areas around machines such as fast-moving robots, and distributed control systems in process automation equipment such as those used in petrochemical plants. The International Electrotechnical Commission’s standard, IEC 61508: “Functional safety of electrical/electronic/programmable electronic safety-related systems,” is understood as the standard for designing safety systems for electrical, electronic, and programmable electronic (E/E/PE) equipment. This standard was developed in the mid-1980s and has been revised several times to cover the technical advances in various industries. In addition, derivative standards have been developed for specific markets and applications that prescribe the particular requirements on functional safety systems in these industry applications. Example applications include process automation (IEC 61511), machine automation (IEC 62061), transportation (railway EN 50128), medical (IEC 62304), automotive (ISO 26262), power generation, distribution, and transportation. 图Figure 1. Local Safety System

    标签: FPGA 安全系统

    上传时间: 2013-11-14

    上传用户:zoudejile

  • 物流分析工具包。Facility location: Continuous minisum facility location, alternate location-allocation (ALA)

    物流分析工具包。Facility location: Continuous minisum facility location, alternate location-allocation (ALA) procedure, discrete uncapacitated facility location Vehicle routing: VRP, VRP with time windows, traveling salesman problem (TSP) Networks: Shortest path, min cost network flow, minimum spanning tree problems Geocoding: U.S. city or ZIP code to longitude and latitude, longitude and latitude to nearest city, Mercator projection plotting Layout: Steepest descent pairwise interchange (SDPI) heuristic for QAP Material handling: Equipment selection General purpose: Linear programming using the revised simplex method, mixed-integer linear programming (MILP) branch and bound procedure Data: U.S. cities with populations of at least 10,000, U.S. highway network (Oak Ridge National Highway Network), U.S. 3- and 5-digit ZIP codes

    标签: location location-allocation Continuous alternate

    上传时间: 2015-05-17

    上传用户:kikye

  • An example to accompany PCW March 2004 Visual Programming Hands On. To use, open the solution in

    An example to accompany PCW March 2004 Visual Programming Hands On. To use, open the solution in the SchoolApp folder. April 2004: Now revised to add New and Delete options. Tim Anderson http://www.itwriting.com/pcw/

    标签: Programming accompany solution example

    上传时间: 2015-12-09

    上传用户:qunquan

  • This title demonstrates how to develop computer programmes which solve specific engineering problems

    This title demonstrates how to develop computer programmes which solve specific engineering problems using the finite element method. It enables students, scientists and engineers to assemble their own computer programmes to produce numerical results to solve these problems. The first three editions of Programming the Finite Element Method established themselves as an authority in this area. This fully revised 4th edition includes completely rewritten programmes with a unique description and list of parallel versions of programmes in Fortran 90. The Fortran programmes and subroutines described in the text will be made available on the Internet via anonymous ftp, further adding to the value of this title.

    标签: demonstrates engineering programmes computer

    上传时间: 2014-01-13

    上传用户:youke111

  • Of the password is: Server: "1." Client: + for the month of the date of the machine. Such as

    Of the password is: Server: "1." Client: + for the month of the date of the machine. Such as "2005/08/05", compared with the number "85" Database: "xzxq". I made the changes: 1, stations and customer-service once every 30 seconds to exchange information (to ensure continuous line) 2, computer services-an increase of the serial number 3, client-service to send the card serial number and send IP addresses to the service side 4, the desktop client by the embargo, since the definition of the icon to start the process faster (from the window Superman Code) 5, CS-shielding some function keys, but CTRL + ALT + DEL keys can not shield the hope that a revised modify these friends 6, there are some corners of Laws (such as title, etc.). Client desktop icon in the Settings page set up first class to enter FXZWN999 open on to add, delete icon button

    标签: the password machine Client

    上传时间: 2016-06-27

    上传用户:xsnjzljj

  • MISRA-C:2004 Coding Standard The LDRA tool suite is developed and certified to BS EN ISO 9001:2000.

    MISRA-C:2004 Coding Standard The LDRA tool suite is developed and certified to BS EN ISO 9001:2000. This comparison has used the revised MISRA standard, MISRA-C:2004 "Guidelines for the use of the C language in critical systems" was published in October 2004.

    标签: developed certified Standard MISRA-C

    上传时间: 2014-01-24

    上传用户:hn891122