This book introduces students to the theory and practice of control systems engineer- ing. The text emphasizes the practical application of the subject to the analysis and design of feedback systems. The study of control systems engineering is essential for students pursuing degrees in electrical, mechanical, aerospace, biomedical, or chemical engineering. Control systems are found in a broad range of applications within these disciplines, from aircraft and spacecraft to robots and process control systems.
标签: Control Systems Engineering
上传时间: 2020-06-10
上传用户:shancjb
My association with the theory of controls in continuous time started during my studies at the Indian Institute of Technology, Kharagpur, India, in 1974 as an undergraduate student in the Controls and Power program. The initial introduction by Professors Kesavamurthy, Y. P. Singh, and Rajagopalan laid the foundation for a good basic understanding of the subject matter. This pursuit and further advanced study in the field of digital controls continued during my days as a graduate student in the electrical and Systems Engineering Department at the University of Connecticut in Storrs, from 1983 to 1988.
标签: Applications Digital Control
上传时间: 2020-06-10
上传用户:shancjb
This book will discuss the topic of Control Systems, which is an interdisciplinary engineering topic. Methods considered here will consist of both "Classical" control methods, and "Modern" control methods. Also, discretely sampled systems (digital/computer systems) will be considered in parallel with the more common analog methods. This book will not focus on any single engineering discipline (electrical, mechanical, chemical, etc.), although readers should have a solid foundation in the fundamentals of at least one discipline.
上传时间: 2020-06-10
上传用户:shancjb
The large-scale deployment of the smart grid (SG) paradigm could play a strategic role in supporting the evolution of conventional electrical grids toward active, flexible and self- healing web energy networks composed of distributed and cooperative energy resources. From a conceptual point of view, the SG is the convergence of information and operational technologies applied to the electric grid, providing sustainable options to customers and improved security. Advances in research on SGs could increase the efficiency of modern electrical power systems by: (i) supporting the massive penetration of small-scale distributed and dispersed generators; (ii) facilitating the integration of pervasive synchronized metering systems; (iii) improving the interaction and cooperation between the network components; and (iv) allowing the wider deployment of self-healing and proactive control/protection paradigms.
标签: Computational Intelligence
上传时间: 2020-06-10
上传用户:shancjb
UL Standard for Safety for Automatic electrical Controls for Household and Similar Use, Part 1: GeneralRequirements, UL 60730-1Fourth Edition, Dated October 19, 2009Summary of TopicsThis new edition of UL 60730–1 is being issued to:1) Adopt IEC’s Amendments No. 1 and No. 2 of IEC 60730-1.2) Adopt UL’s proposed changes to the national differences.
标签: ul60730
上传时间: 2021-10-21
上传用户:ttalli
Road vehicles — Environmental conditions and testing for electrical and electronic equipment — Part 5:Chemical loads(EN)ISO16750-5 道路车辆-电气和电子设备的环境条件和测试 第5部分:化学负荷
上传时间: 2021-10-31
上传用户:
基于TMS320F2812 光伏并网发电模拟装置PROTEL设计原理图+PCB+软件源码+WORD论文文档,硬件采用2层板设计,PROTEL99SE 设计的工程文件,包括完整的原理图和PCB文件,可以做为你的学习设计参考。 摘要:本文实现了一个基于TMS320F2812 DSP芯片的光伏并网发电模拟装置,采用直流稳压源和滑动变阻器来模拟光伏电池。通过TMS320F2812 DSP芯片ADC模块实时采样模拟电网电压的正弦参考信号、光伏电池输出电压、负载电压电流反馈信号等。经过数据处理后,用PWM模块产生实时的SPWM 波,控制MOSFET逆变全桥输出正弦波。本文用PI控制算法实现了输出信号对给定模拟电网电压的正弦参考信号的频率和相位跟踪,用恒定电压法实现了光伏电池最大功率点跟踪(MPPT),从而达到模拟并网的效果。另外本装置还实现了光伏电池输出欠压、负载过流保护功能以及光伏电池输出欠压、过流保护自恢复功能、声光报警功能、孤岛效应的检测、保护与自恢复功能。系统测试结果表明本设计完全满定设计要求。关键词:光伏并网,MPPT,DSP Photovoltaic Grid-connected generation simulator Zhangyuxin,Tantiancheng,Xiewuyang(College of electrical Engineering, Chongqing University)Abstract: This paper presents a photovoltaic grid-connected generation simulator which is based on TMS320F2812 DSP, with a DC voltage source and a variable resistor to simulate the characteristic of photovoltaic cells. We use the internal AD converter to real-time sampling the referenced grid voltage signal, outputting voltage of photovoltaic, feedback outputting voltage and current signal. The PWM module generates SVPWM according to the calculation of the real-time sampling data, to control the full MOSFET inverter bridge output sine wave. We realized that the output voltage of the simulator can track the frequency and phase of the referenced grid voltage with PI regulation, and the maximum photovoltaic power tracking with constant voltage regulation, thereby achieved the purpose of grid-connected simulation. Additionally, this device has the over-voltage and over-current protection, audible and visual alarm, islanding detecting and protection, and it can recover automatically. The testing shows that our design is feasible.Keywords: Photovoltaic Grid-connected,MPPT,DSP 目录引言 11. 方案论证 11.1. 总体介绍 11.2. 光伏电池模拟装置 11.3. DC-AC逆变桥 11.4. MOSFET驱动电路方案 21.5. 逆变电路的变频控制方案 22. 理论分析与计算 22.1. SPWM产生 22.1.1. 规则采样法 22.1.2. SPWM 脉冲的计算公式 32.1.3. SPWM 脉冲计算公式中的参数计算 32.1.4. TMS320F2812 DSP控制器的事件管理单元 42.1.5. 软件设计方法 62.2. MPPT的控制方法与参数计算 72.3. 同频、同相的控制方法和参数计算 8
标签: tms320f2812 光伏 并网发电 模拟 protel pcb
上传时间: 2021-11-02
上传用户:
It all started rather innocuously. I walked into Dr GT Murthy’s office one fine day, andchanged my life. “Doc” was then the General Manager, Central R&D, of a very largeelectrical company headquartered in Bombay. In his new state-of-the-art electronics center,he had hand-picked some of India’s best engineers (over a hundred already) ever assembledunder one roof. Luckily, he too was originally a Physicist, and that certainly helped me gainsome empathy. Nowadays he is in retirement, but I will always remember him as athoroughly fair, honest and facts-oriented person, who led by example. There were severalthings I absorbed from him that are very much part of my basic engineering persona today.You can certainly look upon this book as an extension of what Doc started many years agoin India … because that’s what it really is! I certainly wouldn’t be here today if I hadn’t metDoc. And in fact, several of the brash, high-flying managers I’ve met in recent years,desperately need some sort of crash course in technology and human values from Doc!
标签: 开关电源
上传时间: 2021-11-23
上传用户:
基于LabVIEW2012FPGA模式的数据采集和存储系统摘 要:为了提高数据采集系统精度,减少开发成本,提高开发效率,基于LabVIEW虚拟仪器开发工具研究并设计了一 种数据采集系统。该系统采用FPGA编程模式和网络流技术实现大批量数据实时传输,并对数据进行分析处理和存储。系 统硬件采用美国NI实时控制器CRIO⁃9025,实现16路数据可靠采集与存储。实验仿真及实际运行结果表明该数据采集系 统能够精确地对数据进行实时采集以及分析处理,达到了项目要求。 关键词:FPGA;FIFO;网络流;数据采集系统;SQL数据库 中图分类号:TN98⁃34 文献标识码:A 文章编号:1004⁃373X(2014)14⁃0142⁃04 Data acquisition and storage system based on LabVIEW 2012FPGA pattern WANG Shu⁃dong1,2 ,WEI Kong⁃zhen1 ,LI Xiao⁃pei1 (1. College of electrical and Information Engineering,Lanzhou University of Technology,Lanzhou 730050,China; 2. Gansu Key Laboratory for Advanced Industrial Process Control,Lanzhou 730050,China)
上传时间: 2022-02-18
上传用户:
Agilent 34401A Service Guide.pdfIEC Measurement Category II includes electrical devices connected to mains at an outlet on a branch circuit. Such devices include most small appliances, test equipment, and other devices that plug into a branch outlet or socket. The 34401A may be used to make measurements with the HI and LO inputs connected to mains in such devices, or to the branch outlet itself (up to 300 VAC). However, the 34401A may not be used with its HI and LO inputs connected to mains in permanently installed electrical devices such as the main circuit-breaker panel, sub-panel disconnect boxes, or permanently wired motors. Such devices and circuits are subject to overvoltages that may exceed the protection limits of the 34401A. Note: Voltages above 300 VAC may be measured only in circuits that are isolated from mains. However, transient overvoltages are also present on circuits that are isolated from mains. The Agilent 34401A are designed to safely withstand occasional transient overvoltages up to 2500 Vpk. Do not use this equipment to measure circuits where transient overvoltages could exceed this level. Additional Notices Waste electrical and Electronic Equipment (WEEE) Directive 2002/96/EC This product complies with the WEEE Directive (2002/96/EC) marking requirement. The affixed product label (see below) indicates that you must not discard this electrical/electronic product in domestic household waste. Product Category: With reference to the equipment types in the WEEE directive Annex 1, this product is classified as a "Monitoring and Control instrumentation" product. Do not dispose in domestic household waste. To return unwanted products, contact your local Agilent office, or see www.agilent.com/environment/product for more information. Agilent 34138A Test Lead Set The Agilent 34401A is compatible with the Agilent 34138A Test Lead Set described below. Test Lead Ratings Test Leads - 1000V, 15A Fine Tip Probe Attachments - 300V, 3A Mini Grabber Attachment - 300V, 3A SMT Grabber Attachments - 300V, 3A Operation The Fine Tip, Mini Grabber, and SMT Grabber attachments plug onto the probe end of the Test Leads. Maintenance If any portion of the Test Lead Set is worn or damaged, do not use. Replace with a new Agilent 3413
标签: agilent
上传时间: 2022-02-20
上传用户: