In industrial applications, high voltage power supply spikes with durations ranging from a few microseconds to hundreds of millisecondsare commonly encountered. The electronics in these systems must not only survive transient voltage spikes, but in many Cases alsooperate reliably throughout the event.
上传时间: 2013-11-07
上传用户:redmoons
Automotive power systems are unforgiving electronicenvironments. Transients to 90V can occur when thenominal voltage range is 10V to 15V (ISO7637), along withbattery reversal in some Cases. It’s fairly straightforwardto build automotive electronics around this system, butincreasingly end users want to operate portable electronics,such as GPS systems or music/video players,and to charge their Li-Ion batteries from the automotivebattery. To do so requires a compact, robust, effi cientand easy-to-design charging system
上传时间: 2013-11-04
上传用户:wfl_yy
单片机作为一种微型计算机,其内部具有一定的存储单元(8031除外),但由于其内部存储单元及端口有限,很多情况下难以满足实际需求。为此介绍一种新的扩展方法,将数据线与地址线合并使用,通过软件控制的方法实现数据线与地址线功能的分时转换,数据线不仅用于传送数据信号,还可作为地址线、控制线,用于传送地址信号和控制信号,从而实现单片机与存储器件的有效连接。以单片机片外256KB数据存储空间的扩展为例,通过该扩展方法,仅用10个I/O端口便可实现,与传统的扩展方法相比,可节约8个I/O端口。 Abstract: As a micro-computer,the SCM internal memory has a certain units(except8031),but because of its internal storage units and the ports are limited,in many Cases it can not meet the actual demand.So we introduced a new extension method,the data line and address lines combined through software-controlled approach to realize the time-conversion functions of data lines and address lines,so the data lines not only transmited data signals,but also served as address lines and control lines to transmit address signals and control signals,in order to achieve an effective connection of microcontroller and memory chips.Take microcontroller chip with256KB of data storage space expansion as example,through this extension method,with only10I/O ports it was achieved,compared with the traditional extension methods,this method saves8I/O ports.
上传时间: 2014-12-26
上传用户:adada
The TL2575 and TL2575HV represent superior alternatives to popular three-terminal linear regulators. Due totheir high efficiency, the devices significantly reduce the size of the heatsink and, in many Cases, no heatsink isrequired. Optimized for use with standard series of inductors available from several different manufacturers, theTL2575 and TL2575HV greatly simplify the design of switch-mode power supplies by requiring a minimaladdition of only four to six external components for operation.
标签: STEP-DOWN SWITCHING SIMPLE 1A
上传时间: 2013-11-20
上传用户:jelenecheung
This white paper discusses how market trends, the need for increased productivity, and new legislation have accelerated the use of safety systems in industrial machinery. This TÜV-qualified FPGA design methodology is changing the paradigms of safety designs and will greatly reduce development effort, system complexity, and time to market. This allows FPGA users to design their own customized safety controllers and provides a significant competitive advantage over traditional microcontroller or ASIC-based designs. Introduction The basic motivation of deploying functional safety systems is to ensure safe operation as well as safe behavior in Cases of failure. Examples of functional safety systems include train brakes, proximity sensors for hazardous areas around machines such as fast-moving robots, and distributed control systems in process automation equipment such as those used in petrochemical plants. The International Electrotechnical Commission’s standard, IEC 61508: “Functional safety of electrical/electronic/programmable electronic safety-related systems,” is understood as the standard for designing safety systems for electrical, electronic, and programmable electronic (E/E/PE) equipment. This standard was developed in the mid-1980s and has been revised several times to cover the technical advances in various industries. In addition, derivative standards have been developed for specific markets and applications that prescribe the particular requirements on functional safety systems in these industry applications. Example applications include process automation (IEC 61511), machine automation (IEC 62061), transportation (railway EN 50128), medical (IEC 62304), automotive (ISO 26262), power generation, distribution, and transportation. 图Figure 1. Local Safety System
上传时间: 2013-11-05
上传用户:维子哥哥
Xilinx FPGAs require at least two power supplies: VCCINTfor core circuitry and VCCO for I/O interface. For the latestXilinx FPGAs, including Virtex-II Pro, Virtex-II and Spartan-3, a third auxiliary supply, VCCAUX may be needed. Inmost Cases, VCCAUX can share a power supply with VCCO.The core voltages, VCCINT, for most Xilinx FPGAs, rangefrom 1.2V to 2.5V. Some mature products have 3V, 3.3Vor 5V core voltages. Table 1 shows the core voltagerequirement for most of the FPGA device families. TypicalI/O voltages (VCCO) vary from 1.2V to 3.3V. The auxiliaryvoltage VCCAUX is 2.5V for Virtex-II Pro and Spartan-3, andis 3.3V for Virtex-II.
上传时间: 2013-10-22
上传用户:liu999666
This white paper discusses how market trends, the need for increased productivity, and new legislation have accelerated the use of safety systems in industrial machinery. This TÜV-qualified FPGA design methodology is changing the paradigms of safety designs and will greatly reduce development effort, system complexity, and time to market. This allows FPGA users to design their own customized safety controllers and provides a significant competitive advantage over traditional microcontroller or ASIC-based designs. Introduction The basic motivation of deploying functional safety systems is to ensure safe operation as well as safe behavior in Cases of failure. Examples of functional safety systems include train brakes, proximity sensors for hazardous areas around machines such as fast-moving robots, and distributed control systems in process automation equipment such as those used in petrochemical plants. The International Electrotechnical Commission’s standard, IEC 61508: “Functional safety of electrical/electronic/programmable electronic safety-related systems,” is understood as the standard for designing safety systems for electrical, electronic, and programmable electronic (E/E/PE) equipment. This standard was developed in the mid-1980s and has been revised several times to cover the technical advances in various industries. In addition, derivative standards have been developed for specific markets and applications that prescribe the particular requirements on functional safety systems in these industry applications. Example applications include process automation (IEC 61511), machine automation (IEC 62061), transportation (railway EN 50128), medical (IEC 62304), automotive (ISO 26262), power generation, distribution, and transportation. 图Figure 1. Local Safety System
上传时间: 2013-11-14
上传用户:zoudejile
Xilinx FPGAs require at least two power supplies: VCCINTfor core circuitry and VCCO for I/O interface. For the latestXilinx FPGAs, including Virtex-II Pro, Virtex-II and Spartan-3, a third auxiliary supply, VCCAUX may be needed. Inmost Cases, VCCAUX can share a power supply with VCCO.The core voltages, VCCINT, for most Xilinx FPGAs, rangefrom 1.2V to 2.5V. Some mature products have 3V, 3.3Vor 5V core voltages. Table 1 shows the core voltagerequirement for most of the FPGA device families. TypicalI/O voltages (VCCO) vary from 1.2V to 3.3V. The auxiliaryvoltage VCCAUX is 2.5V for Virtex-II Pro and Spartan-3, andis 3.3V for Virtex-II.
上传时间: 2013-10-22
上传用户:aeiouetla
ARM下 Implement matrix multiplication of 2 square matrices, with data read from an input file and printed both to the console and to an output file. • Assume a file with correct data (no garbage, characters, etc.). • you must check and provide appropriate execution for 2 extra Cases, namely when the matrix size given is either “0” , or when the size is greater than the maximum handled of “5” . In these 2 Cases you must implement the following behaviour: o If size = 0, then print a message “Size = 0 is unacceptable” and continue by reading the next size for the next 2 matrices (if not end of file). o If size >5, then print two messages: “Size is too big - unacceptable”. Then read and discard the next (size2 ) integers and continue by reading the next size for the next 2 matrices (if not end of file).
标签: multiplication Implement matrices matrix
上传时间: 2014-08-30
上传用户:dsgkjgkjg
Wiley Professional Ajax By Nicholas C. Zakas, Jeremy McPeak & Joe Fawcett Professional Ajax provides a developer-level tutorial of Ajax techniques, patterns, and use Cases.
标签: Professional C. Ajax Nicholas
上传时间: 2013-12-12
上传用户:bcjtao