代码搜索:zend
找到约 2,728 项符合「zend」的源代码
代码结果 2,728
www.eeworm.com/read/233250/14161502
dat input2.dat
maxx maxy maxz dx dy dz(in meter)
15 54 80 .265e-3 .4064e-3 .406e-3
number of dielectric "bricks"(including air region)
2
xstart xend ystart yend zstart zend epsr tand@10GHz
1 3 1 54 1 80 2.2 0
www.eeworm.com/read/233250/14161504
dat input1.dat
maxx maxy maxz dx dy dz(in meter)
17 42 30 .05e-3 .04286e-3 .04286e-3
number of dielectric "bricks"(including air region)
2
xstart xend ystart yend zstart zend epsr tand@10GHz
1 5 1 42 1 30 12.9
www.eeworm.com/read/233250/14161506
dat input2.dat
maxx maxy maxz dx dy dz(in meter)
17 42 80 .05e-3 .04286e-3 .04286e-3
number of dielectric "bricks"(including air region)
2
xstart xend ystart yend zstart zend epsr tand@10GHz
1 5 1 42 1 80 12.9
www.eeworm.com/read/233250/14161507
dat input1.dat
maxx maxy maxz dx dy dz(in meter)
16 80 30 .265e-3 .4064e-3 .4233e-3
number of dielectric "bricks"(including air region)
2
xstart xend ystart yend zstart zend epsr tand@10GHz
1 3 1 80 1 30 2.2 0.
www.eeworm.com/read/233250/14161509
dat input2.dat
maxx maxy maxz dx dy dz(in meter)
16 80 60 .265e-3 .4064e-3 .4233e-3
number of dielectric "bricks"(including air region)
2
xstart xend ystart yend zstart zend epsr tand@10GHz
1 3 1 80 1 60 2.2 0.
www.eeworm.com/read/233250/14161510
dat input1.dat
maxx maxy maxz dx dy dz(in meter)
60 140 30 .2e-3 .25e-3 .3333e-3
number of dielectric "bricks"(including air region)
2
xstart xend ystart yend zstart zend epsr tand@10GHz
1 30 1 140 1 30 12. 0.
www.eeworm.com/read/233250/14161511
dat input2.dat
maxx maxy maxz dx dy dz(in meter)
60 140 70 .2e-3 .25e-3 .3333e-3
number of dielectric "bricks"(including air region)
2
xstart xend ystart yend zstart zend epsr tand@10GHz
1 30 1 140 1 70 12. 0.
www.eeworm.com/read/233250/14161513
dat input1.dat
maxx maxy maxz dx dy dz(in meter)
20 53 30 .2625e-3 .762e-3 .4075e-3
number of dielectric "bricks"(including air region)
2
xstart xend ystart yend zstart zend epsr tand@10GHz
1 20 1 53 1 30 1. 0
www.eeworm.com/read/233250/14161515
dat input2.dat
xmax ymax zmax dx dy dz(in meter)
20 53 80 .2625e-3 .762e-3 .4075e-3
number of dielectric "bricks"(including air region)
2
xstart xend ystart yend zstart zend epsr tand@10GHz
1 20 1 53 1 80 1. 0
www.eeworm.com/read/233250/14161517
dat input.dat
maxx maxy maxz dx dy dz(in meter)
16 28 80 .125e-3 .125e-3 .125e-3
number of dielectric "bricks"(including air region)
2
xstart xend ystart yend zstart zend epsr tand@10GHz
1 4 1 28 1 80 9.6 0.0