000 Reserved.
010 Reserved.
020 Reserved.
150 %%%% MACHEXP %%%% Program successful.  File  %s
150 %%%% MACHEXP %%%% ERROR count  %d  WARNING count  %d
160 %%%% MACHEXP %%%% Program unsuccessful.  File  %s
160 %%%% MACHEXP %%%% ERROR count  %d  WARNING count  %d
200 |> SYSTEM_ERROR E0200
200     Output message file %s open error. Call AMD, 1-800-222-9323.
210 |> SYSTEM_ERROR E0210
210     Output message file close error. Call AMD, 1-800-222-9323.
1010 |> INTERNAL_ERROR E1010
1010     Multiple defaults in transition equations of state %s.
1020 |> INTERNAL_ERROR E1020
1020     Multiple state transition equations for the same state %s.
1110 |> INTERNAL_ERROR E1110
1110     Multiple defaults in output equation of state %s.
1120 |> INTERNAL_ERROR E1120
1120     Multiple state output equations for the same state %s.
1200 |> ERROR E1200
1200     Moore and Mealy directives both used.
1210 |> ERROR E1210
1210     Moore machine with conditional outputs.
1215 |> ERROR E1215
1215     Device %s does not support MASTER_RESET feature.
1216 |> ERROR E1216
1216     Device %s does not support OUTPUT_ENABLE feature.
1217 |> ERROR E1217
1217     MASTER_RESET and OUTPUT_ENABLE features cannot be used
1217     together in the same design.
1220 |> INTERNAL_ERROR E1220
1220     Missing transition equation for state %s.
1230 |> INTERNAL_ERROR E1230
1230     Missing transition equation for state %s.
1230     Using DEFAULT_BRANCH to transition into state %s.
1250 |> ERROR E1250
1250     Conflicting conditions in transition equation of
1250     state %s.
1260 |> ERROR E1260
1260     Conflicting conditions in output equation of state %s.
1270 |> ERROR E1270
1270     Startup states %s and %s are different.
1271 |> ERROR E1271
1271     Device %s does not support programmable initialization.
1272 |> ERROR E1272
1272     Device %s does not support multiple condition
1272     product terms for startup programmable initialization.
1273 |> WARNING E1273
1273     For Mealy machines with registered outputs
1273     you must define a STARTUP.OUTF.
1274 |> WARNING E1274
1274     START_UP Initialization.
1274     Swapping values of state %s and state %s
1275 |> WARNING E1275
1275     START_UP Initialization.  Setting value of the state
1275     %s to %s's natural power up.
1276 |> ERROR E1276
1276     START_UP state %s is undefined.
1276     All defined states either have a state transition
1276     equation or a state assignment equation.
1277 |> WARNING E1277
1277     Output specified in START_UP.OUTF statement conflicts
1277     with the physical power up output value of %s.
1278 |> WARNING E1278
1278     Startup state's outputs are defined.  Ignoring
1278     START_UP.OUTF statement.
1280 |> WARNING E1280
1280     Cannot show more than 8 state bits on the screen.
1290 |> ERROR   E1290
1290     State bits of STATE %s and STATE %s are identical.
1292 |> ERROR E1292
1292     Multiple state transition equations for the
1292     same state %s.
1295 |> WARNING E1295
1295     No. of states: %d  State bits reqd: %d
1295     State bits used: %d
1300 |> WARNING E1300
1300     DEFAULT_BRANCH NEXT_STATE is specified, but the last
1300     state, %s, does not have an explicit next state
1300     defined.
1310 |> WARNING E1310
1310     Missing default next state in transition equations
1310     of state %s.
1320 |> WARNING E1320
1320     State %s is never reached in the State Machine.
1330 |> WARNING E1330
1330     Hold directive specified on a combinatorial pin.
1350 |> WARNING E1350
1350     Automatically assigning state bit %s to pin %d.
1351 |> WARNING E1351
1351     Automatically assigning state bit %s to ? NODE.
1354 |> ERROR E1354
1354     POWER_UP feature is not supported for Device %s.
1355 |> WARNING E1355
1355     POWER_UP Initialization.
1355     Swapping values of state POWER_UP and state %s.
1356 |> WARNING E1356
1356     POWER_UP Initialization.
1356     Setting value of the state POWER_UP to %s's
1356     natural power up.
1358 |> WARNING E1358
1358     Possible equation conflict on pin.  Output pin %s
1358     is declared and the buried node is used for state
1358     assignment.  Output %s and node %d are both used.
1360 |> ERROR E1360
1360     State bit assignment failed.
1400 |> ERROR E1400
1400     State bit %s assigned to combinatorial output.
1430 |> WARNING E1430
1430     Device %s requires START_UP syntax so that the device powers
1430     up to a known state.
1500 |> ERROR E1500
1500     START_UP syntax is not supported for this device. Please read the
1500     section in the manual on Powering up to a known state.  Also
1500     read the STARTUP.DOC in the \doc sub-directory for more
1500     information.
1510 |> WARNING E1510
1510     Creating %s pin for OUTPUT_ENABLE/MASTER_RESET feature.
1600 |> INTERNAL_ERROR E1600
1600     AUTO STATE BIT ASSIGNMENT:
1600     Undefined value for state bit.
1600     Call AMD, 1-800-222-9323.
1610 |> WARNING E1610
1610     State value equation of state %s is incompletely
1610     specified. All the state bits are not explicitly
1610     defined. Automatically assigning all unspecified
1610     state bits.
1620 |> INTERNAL ERROR E1620
1620     AUTO STATE BIT ASSIGNMENT:
1620     Cannot have more than 32 signals for state
1620     assignment equation.  Call AMD, 1-800-222-9323
1630 |> SYSTEM_ERROR E1630
1630     AUTO STATE BIT ASSIGNMENT:
1630     Memory allocation failed.  Out of memory.
1630     Call AMD, 1-800-222-9323.
1800 |> INTERNAL_ERROR E1800
1800     Illegal simulation command type (%d).
1800     Call AMD, 1-800-222-9323.
1810 |> ERROR E1810
1810     Condition %s present in simulation statement %s.
1810     Condition names are not allowed in Simulation section.
1820 |> INTERNAL_ERROR E1820
1820     Illegal simulation element.
1830 |> WARNING E1830
1830     Simulation state %s not active.
2000 |> SYSTEM_ERROR E2000
2000     Input intermediate file (.TRE) open error.
2010 |> SYSTEM_ERROR E2010
2010     Input intermediate file (.TRE) close error.
2030 |> SYSTEM_ERROR E2030
2030     Output intermediate file (.TRE) copy error.
2040 |> ERROR E2040
2040     State %s has %s outputs. All previous states
2040     have %s outputs. A state machine can either have
2040     all REGISTERED outputs or all COMBINATORIAL outputs
2040     or all LATCHED outputs, not a mixture of them.
2050 |> ERROR E2050
2050     State %s has both %s and %s pins in its
2050     output equation. Pin %d namely %s is a %s  pin
2050     whereas other pins are %s. An output equation cannot
2050     contain a mixture of pintypes.
2100 |> INTERNAL_ERROR E2100
2100     Illegal equation for state segment.
2110 |> INTERNAL_ERROR E2110
2110     Illegal equation in conditions segment.
2120 |> INTERNAL_ERROR E2120
2120     Illegal equation in equations segment.
2130 |> INTERNAL_ERROR E2130
2130     Illegal equation in simulation segment.
2140 |> SYSTEM_ERROR E2140
2140     Input intermediate file (.TRE) read error.
2400 |> SYSTEM_ERROR E2400
2400     Output intermediate file (.TRE) open error.
2410 |> SYSTEM_ERROR E2410
2410     Output intermediate file (.TRE) write error.
2410     Illegal equation detected.
2420 |> SYSTEM_ERROR E2420
2420     Output intermediate file (.TRE) write error.
2430 |> SYSTEM_ERROR E2430
2430     Output intermediate file (.TRE) close error.
2440 |> SYSTEM_ERROR E2440
2440     Output Simulation file (TBL) Open Error.
2450 |> SYSTEM_ERROR E2450
2450     Output Simulation file (TBL) Close Error.
2700 |> INTERNAL_ERROR E2700
2700     Input intermediate file (.TRE) syntax error.
2715 |> ERROR E2715
2715     Device %s  does not support NCLKF feature.
2724 |> ERROR E2724
2724     %s is an undefined STATE name.
2724     Only defined state names can be used in the
2724     DEFAULT_BRANCH statement.
2725 |> ERROR E2725
2725     %s is not a complementary array pin.
2725     Only complementary array pins can be used in the
2725     DEFAULT_BRANCH statement.
2730 |> ERROR E2730
2730     ILLEGAL Syntax in DEFAULT_BRANCH statement.
2750 |> INTERNAL_ERROR E2750
2750     Illegal syntax of state output equation.
2770 |> ERROR E2770
2770     In an OUTPUT_HOLD statement only pin names can be
2770     specified. Not their polarities or any other logical
2770     operator.
2780 |> ERROR E2780
2780     The OUTPUT_HOLD statement can only have output pins
2780     following it.  Pin %s is not an OUTPUT pin.
2790 |> ERROR E2790
2790     The OUTPUT_HOLD statement can only have REGISTERED
2790     or LATCHED pins.  Pin %s is COMBINATORIAL.
2791 |> ERROR E2791
2791     State %s has a state assignment equation but is
2791     missing a transition equation.
2792 |> ERROR E2792
2792     State %s has a state output equation but is
2792     missing a transition equation.
2793 |> ERROR E2793
2793     Transition equation of state %s shows a transition
2793     into an unknown state %s.  All known states have
2793     state transition equations.
2830 |> INTERNAL_ERROR E2830
2830     Unknown Token in TRE file.
2830     Call AMD, 1-800-222-9323.
2840 |> INTERNAL_ERROR E2840
2840     Corrupt .TRE file format.  Boolean Binary
2840     Operators do not have two children.
2840     Call AMD, 1-800-222-9323.
2870 |> INTERNAL_ERROR E2870
2870     Illegal token detected in simulation segment.
2870     Call AMD, 1-800-222-9323.
2890 |> INTERNAL_ERROR E2890
2890     Illegal State assignment equations.
2890     Call AMD, 1-800-222-9323.
3000 |> ERROR E3000
3000     Cannot support this device.
3001 |> SYSTEM_ERROR E3001
3001     Cannot open PALEXMIN.PDF file.
3001     Call AMD, 1-800-222-9323.
3002 |> ERROR E3002
3002     Cannot support this PAL device.
3003 |> SYSTEM_ERROR E3003
3003     Incorrect PALEXMIN.PDF file format.
3003     Call AMD, 1-800-222-9323.
3011 |> SYSTEM_ERROR E3011
3011     Cannot open PLSPDF.PDF file.
3011     Call AMD, 1-800-222-9323.
3013 |> SYSTEM_ERROR E3013
3013     Incorrect PLSPDF.PDF file format.
3013     Call AMD, 1-800-222-9323.
3014 |> INTERNAL_ERROR E3014
3014     Data structure for device incorrectly formed
3014     from PLSPDF.PDF. Call AMD, 1-800-222-9323.
3021 |> SYSTEM_ERROR E3021
3021     Cannot open MACHPDF.PDF file.
3021     Call AMD, 1-800-222-9323.
3022 |> ERROR E3022
3022     Cannot support this MACH device.
3023 |> SYSTEM_ERROR E3023
3023     Incorrect MACHPDF.PDF file format.
3023     Call AMD, 1-800-222-9323.
3030 |> SYSTEM_ERROR E3030
3030     Memory allocation failed.  Out of memory.
3030     Call AMD, 1-800-222-9323.
3060 |> ERROR E3060
3060     Cannot support prose device.
3400 |> INTERNAL_ERROR E3400
3400     Boolean expression processing failed.  Illegal
3400     token found.  Call AMD, 1-800-222-9323.
3410 |> INTERNAL_ERROR E3410
3410     State substitution failed.  No state value.
3410     Call AMD, 1-800-222-9323.
3420 |> INTERNAL_ERROR E3420
3420     Condition substitution failed.  Recursive
3420     definition.  Call AMD, 1-800-222-9323.
3430 |> INTERNAL_ERROR E3430
3430     Condition substitution failed.  Non-Boolean
3430     condition.  Unknown condition type.
3430     Call AMD, 1-800-222-9323.
3500 |> ERROR E3500
3500     Boolean expression processing failed.  More than 32
3500     signals on a single output equation.
3550 |> INTERNAL_ERROR E3550
3550     Simulator Boolean expression processing failed.
3550     Call AMD, 1-800-222-9323.
3700 |> SYSTEM_ERROR E3700
3700     Out of memory.  Memory allocation failed.
3700     Call AMD, 1-800-222-9323.
4000 |> ERROR E4000
4000     State %s has more than one state assignment equation.
4020 |> INTERNAL_ERROR E4020
4020     Illegal signal in pin statements.
4020     Call AMD, 1-800-222-9323.
4030 |> ERROR E4030
4030     Duplicate signal %s appears more than once in
4030     state %s bit assignment.
4040 |> INTERNAL_ERROR E4040
4040     Condition has more than one equation.
4050 |> INTERNAL_ERROR E4050
4050     Illegal condition index. Call AMD, 1-800-222-9323.
4100 |> INTERNAL_ERROR E4100
4100     Illegal signal number. Call AMD, 1-800-222-9323.
4110 |> INTERNAL_ERROR E4110
4110     Pin has more than one equation of the same type.
4120 |> ERROR E4120
4120     Minimize switch is different for on and off covers.
4130 |> ERROR E4130
4130     Assignment operator is different for on and off covers.
4300 |> ERROR E4300
4300     Conflicting equations; trying to assign different values
4300     to the same signal.
4500 |> INTERNAL_ERROR E4500
4500     Minimization failed.  Result incorrect.
4500     Call AMD, 1-800-222-9323.
4501 |> SYSTEM_ERROR E4501
4501     Memory allocation failed. Block requested is
4501     too large.  Call AMD, 1-800-222-9323.
4502 |> SYSTEM_ERROR E4502
4502     Memory allocation failed.  Out of memory.
4502     Call AMD, 1-800-222-9323.
4503 |> SYSTEM_ERROR E4503
4503     Memory free failed.  Call AMD, 1-800-222-9323.
4510 |> INTERNAL_ERROR E4510
4510     Esp:  no solution possible (check equations).
4511 |> INTERNAL_ERROR E4511
4511     Esp:  inconsistent frequency table.
4520 |> INTERNAL_ERROR E4520
4520     Esp:  cube not covered in Reduce.
4530 |> INTERNAL_ERROR E4530
4530     Esp:  split_select index error.
4531 |> INTERNAL_ERROR E4531
4531     Esp:  split_two_select index error.
4532 |> INTERNAL_ERROR E4532
4532     Esp:  large_cube_index -- bestindex -1.
4540 |> INTERNAL_ERROR E4540
4540     Esp:  cover capacity exceeded.
4550 |> INTERNAL_ERROR E4550
4550     Esp:  on and off sets overlap (check equations).
4560 |> WARNING E4560
4560     Tree filename is not  unique. Assuming PALASM2.TRE
4560     Use a unique tre filename on the command line.
4570 |> WARNING E4570
4570     Log filename is not unique.  Ignoring log output.
4580
4580 MACHEXP Command Line parameters.
4580     Command to invoke MACHEXP
4580     MACHEXP   [OPTIONS...].
4580     OPTION         [filename[.tre]].
4580                 -tre [filename[.tre]].
4580                 -log [filename[.log]].
4580                 -1eqn
4580                 -t
4580                 -dt
4580     Option flag description:
4580                      [filename[.tre]] - input intermediate filename.
4580                 -tre [filename[.tre]] - output intermediate filename.
4580                 -log [filename[.log]] - error log filename.
4580                 -1eqn  process one equation at a time.
4580                 -t     generate T registered equations only, if they can
4580                        be configured in the device.
4580                 -dt    generate both D and T equations if both D and T
4580                        registers can be configured in the device.
5000 |> SYSTEM_ERROR E5000
5000     Cannot open PARSE.MSG file for device information.
5000     Call AMD, 1-800-222-9323.
10000 |> ERROR E10000
10000     State machine syntax is not supported for
10000     device %s
10001 |> ERROR E10001
10001     You did not run MACHBPP and you should have.
10004 |> SYSTEM_ERROR E10004
10004    Cannot access preheader information.
10004    Call AMD, 1-800-222-9323.