📄 machmin.msg
字号:
1250 ====> %s MIN_OFF (%d %s pt --> %d %s pt)
1260 |> ERROR L1260 Process stopped. The equation has %d product terms
1260 the largest device support has only %d product terms.
1270 |> ERROR L1270 The %s token is not supported in MACHXL.
1300
1310 |> WARNING L1310 Device %s has only %d global clock pins.
1310 Design has %d single-literal clocks that are either
1310 floating or pre-placed at global clock pins.
1310 They are: %s
1320 |> ERROR L1320 Hard disk is full!
1400
1401 |> ERROR L1401 Error in TRE file.
1401 Please run Parse (Check Syntax).
1500
1600 |> ERROR L1600 Error trying to allocate %ld bytes of memory.
1600 Cannot exceed 64K bytes.
1601 |> INTERNAL_ERROR L1601 set size mismatch error.
1601 Call AMD, 1-800-222-9323.
1620 |> WARNING L1620 Equation was not minimized since it
1620 requires %ld bytes of memory.
1620 Cannot exceed 64K bytes.
1700 |> ERROR L1700 Cannot support this device.
1701 |> SYSTEM_ERROR L1701 Cannot open PALEXMIN.PDF file.
1701 Call AMD, 1-800-222-9323.
1702 |> INTERNAL_ERROR L1702 PAL device not supported in PALEXMIN.PDF.
1702 Call AMD, 1-800-222-9323.
1703 |> SYSTEM_ERROR L1703 Incorrect PALEXMIN.PDF file format.
1703 Call AMD, 1-800-222-9323.
1711 |> SYSTEM_ERROR L1711 Cannot open PLSPDF.PDF file.
1711 Call AMD, 1-800-222-9323.
1712 |> INTERNAL ERROR L1712 PLS device not supported in PLSPDF.PDF.
1712 Call AMD, 1-800-222-9323.
1713 |> SYSTEM_ERROR L1713 Incorrect PLSPDF.PDF file format.
1713 Call AMD, 1-800-222-9323.
1714 |> INTERNAL_ERROR L1714 Incorrect device data structure from
1714 PLSPDF.PDF. Call AMD, 1-800-222-9323.
1721 |> SYSTEM_ERROR L1721 Cannot open MACHPDF.PDF file.
1721 Call AMD, 1-800-222-9323.
1722 |> INTERNAL ERROR L1722 MACH device is not supported in MACHPDF.PDF.
1722 Call AMD, 1-800-222-9323.
1723 |> SYSTEM_ERROR L1723 Incorrect MACHPDF.PDF file format.
1723 Call AMD, 1-800-222-9323.
1730 |> SYSTEM_ERROR L1730 Memory allocation failed. Out of memory.
1730 Call AMD, 1-800-222-9323.
1740 |> SYSTEM_ERROR L1740 Cannot rename design output file.
1740 Call AMD, 1-800-222-9323.
1760 |> INTERNAL_ERROR L1760 Cannot support PROSE device.
1760 Call AMD, 1-800-222-9323.
1780 |> SYSTEM_ERROR L1780 Cannot delete temporary file.
1780 Call AMD, 1-800-222-9323.
1785 |> INTERNAL_ERROR L1785 Cannot support PROSE device.
1790 |> SYSTEM_ERROR L1790 Cannot open PARSE.MSG file for device information.
1790 Call AMD, 1-800-222-9323.
1792 |> ERROR L1792 MACHMIN support MACH devices only. You specify %s.
1795 |> ERROR L1795 MACHMIN does not support device %s
1800 Gate splitting (%s %s) to (NODE ? %s).
1810 |> WARNING L1810 Gate splitting not supported for device %s.
1810 Ignoring (-p) option.
1820 |> ERROR L1820 Device %s can only support a maximum of %d product terms
1820 for %s (%s).
1820 Gate splitting (-p) option specifies %d product terms.
1830 |> ERROR L1830 Device %s can only support a maximum of %d product terms
1830 per pin. Gate splitting option (-p)
1830 specifies %d product terms.
1833 |> WARNING L1833 The %s device supports gate splitting at threshold %d
1833 only. Threshold specified as %d. Changed to %d.
1835 |> WARNING L1835 For the %s device, the signals resulting from
1835 gate splitting can have no more than the specified
1835 maximum of between %d and %d product terms.
1835 Max pterms specified as %d. Changed to %d.
1837 |> WARNING L1837 The %s device supports gate splitting at threshold
1837 between %d and %d. Threshold specified as %d.
1837 changed to %d.
1850 Created paired node equation %s
1851 |> INTERNAL_ERROR L1851 ERROR pin-table-size: %d.
1851 Call AMD, 1-800-222-9323.
1855 |> ERROR L1805 ERROR pin %s and paired-node %s:
1855 Different type of equation for pair.
1857 |> ERROR L1857 Equation %s.TRST is invalid.
1857 MACH devices do not support TRST equation for nodes.
1860 Created paired pin equation %s.
1901 |> ERROR L1901 Incorrect %s equation polarity.
1902 |> WARNING L1902 Device polarity is Non-programmable. Flipping equation
1902 polarity of pin %s to match device polarity.
1910 |> WARNING L1910 Equation polarity of %s has been changed.
1915 |> ERROR L1915 Cannot open file %s.
2000 |> ERROR L2000 Error %s: More than one primary equation exist or
2000 different type of primary eqns for pin and paired node.
2001 |> WARNING L2001 Signal %s doesn't have primary equation.
2002 |> INTERNAL ERROR L2005 Null initial state.
2005 |> INTERNAL ERROR L2005 Unknown initial state %d.
2010 |> INTERNAL ERROR L2010 ERROR XOR equation %s: Lost XORL.
2010 Call AMD, 1-800-222-9323.
2012 |> INTERNAL ERROR L2010 ERROR XOR equation %s: Lost XORR.
2012 Call AMD, 1-800-222-9323.
2015 |> INTERNAL ERROR L2015 ERROR %s: Pol of (XORL, XORR) are different.
2015 Call AMD, 1-800-222-9323.
2020 |> INTERNAL ERROR L2020 ERROR %s: PinNum of (XORL, XORR) are different.
2020 Call AMD, 1-800-222-9323.
2030 |> ERROR L2030 Error equation polarity %s:
2030 Active-low J, K, R, and S equations are prohibited.
2040 |> WARNING L2040 %s option ignored.
2040 Device %s does not have %s registers.
2050 |> WARNING L2050 Equation converted to %s register logic.
2060 |> ERROR L2060 Incomplete JK equation %s: Both J and K must exist.
2065 |> ERROR L2065 Incomplete RS equation %s: Both R and S must exist.
2100 |> WARNING L2100 XOR equation %s expanded.
2100 Both ON and OFF cover exist.
2110 |> WARNING L2110 Multiple-XOR is not supported.
2110 Equation %s expanded to single-XOR form.
2200 |> ERROR L2200 Equation %s: Some minterm(s) belong to both ON-set and
2200 OFF-set which is invalid.
2210 |> WARNING L2210 Duplicated item %s found in group %s.
2210 This item will be ignored.
2300 \n|> ERROR L2300 Error PLA file %s in line %d: unknown character %s.
2310 \n|> ERROR L2310 Syntax error in PLA file %s in line %d.
2320 \n|> ERROR L2320 Syntax error in PLA file %s in line %d.
2320 %d binary number found in LHS plane, should be %d.
2325 \n|> ERROR L2325 Syntax error in PLA file %s in line %d.
2325 %d binary number found in RHS plane, should be %d.
2330 |> ERROR L2330 Too many signals in ".ob" directive.
2332 |> ERROR L2330 Too many signals in ".ilb" directive.
10000
10001 |> ERROR L10001 Please run MACHBPP (Expand Boolean).
10002 |> ERROR L10002 Please run MACHEXP (Expand State).
10003 |> ERROR L10003 Please run MACHMIN without -tre2pla option first.
10530 |> WARNING L10530 Extra .i line ignored.
10540 |> WARNING L10540 Extra .o line ignored.
10550 |> WARNING L10550 Extra .mv ignored.
10560 |> WARNING L10560 Extra .phase ignored.
10570 |> WARNING L10570 Extra .pair ignored.
11200 |> WARNING L11200 Cannot permute columns without names.
11210 |> ERROR L11210 PLA Verify: PLA's are not the same size.
11215 |> ERROR L11215 Cannot compare: PLA's have different input size.
11217 |> ERROR L11217 Cannot compare: PLA's have different output size.
11220 |> ERROR L11220 Equation %s:
11220 Some minterm(s) belong to both the ON-SET and DC-SET.
11230 |> ERROR L11230 Equation %s: Some minterm(s) belong to both ON-set and
11230 OFF-set which is invalid.
11240 |> ERROR L11240 Equation %s:
11240 Some minterm(s) belong to both the OFF-SET and DC-SET.
11250 |> ERROR L11250 There are minterms left unspecified.
11260 |> ERROR L11260 Some minterm in F is not covered by Fold u Dold.
11270 |> ERROR L11270 Some minterm in Fold is not covered by F u Dold
⌨️ 快捷键说明
复制代码
Ctrl + C
搜索代码
Ctrl + F
全屏模式
F11
切换主题
Ctrl + Shift + D
显示快捷键
?
增大字号
Ctrl + =
减小字号
Ctrl + -