📄 sysvdlg.dat
字号:
!HPASSOC|Integer|Registry|1
Controls the associative property of hatch patterns or gradient fills.\n\n0\tHatch patterns and gradient fills are not associated to the boundaries\n1\tHatch patterns and gradient fills are associated to the boundaries and update when the boundaries are changed
!HPBOUND|Integer|Not saved|1
Controls the object type created by the BHATCH and BOUNDARY commands.\n\n0\tCreates a region\n1\tCreates a polyline
!HPDOUBLE|Integer|Not saved|0
Specifies hatch pattern doubling for user-defined patterns.\n\n0\tTurns off hatch pattern doubling\n1\tTurns on hatch pattern doubling
!HPDRAWORDER|Integer|Not saved|3
Controls the draw order for both hatches and fills.\n\n0\tNone. The hatch or fill object is not assigned a draw order value.\n1\tSend to back. The hatch or fill is sent behind all other objects.\n2\tBring to front. The hatch or fill is brought to the front all other objects.\n3\tSend behind boundary. The hatch or fill is sent behind the hatch boundary.\n4\tBring in front of boundary. The hatch or fill is brought in front of the hatch boundary.
!HPGAPTOL|Real|Not saved|0.0000
Specifies the maximum gap (or opening) that is to be bridged when try to form a closed hatch boundary. Valid range is 0 to 5000.
!HPNAME|String|Not saved|"ANSI31"
Sets a default hatch pattern name of up to 34 characters without spaces. Returns "" if there is no default. Enter a period (.) to set no default.
!HPSCALE|Real|Not saved|1.0000
Specifies the hatch pattern scale factor, which must be nonzero.
!HPSPACE|Real|Not saved|1.0000
Specifies the hatch pattern line spacing for user-defined simple patterns, which must be nonzero.
!HYPERLINKBASE|String|Drawing|""
Specifies the path used for all relative hyperlinks in the drawing. If no value is specifed, the drawing path is used for all relative hyperlinks.
!IMAGEHLT|Integer|Registry|0
Controls whether the entire raster image or only the raster image frame is highlighted.\n\n0\tHighlights only the raster image frame\n1\tHighlights the entire raster image
!INDEXCTL|Integer|Drawing|0
Controls whether layer and spatial indexes are created and saved in drawing files.\n\n0\tNo indexes are created\n1\tLayer index is created\n2\tSpatial index is created\n3\tLayer and spatial indexes are created
!INETLOCATION|String|Registry|"http://www.autodesk.com"
Stores the Internet location used by the BROWSER command and the Browse the Web dialog box.
!INSBASE|3D point|Drawing|0.0000,0.0000,0.0000
Stores the insertion base point set by BASE, which gets expressed as a UCS coordinate for the current space.
!INSNAME|String|Not saved|""
Sets a default block name for the INSERT command. The name must conform to symbol naming conventions. Returns "" if no default is set. Enter a period (.) to set no default.
!INSUNITS|Integer|Drawing|1 (imperial) or 4 (metric)
When you drag a block from AutoCAD DesignCenter, specifies a drawing units value as follows:\n\n0\tUnspecified (No units)\n1\tInches\n2\tFeet\n3\tMiles\n4\tMillimeters\n5\tCentimeters\n6\tMeters\n7\tKilometers\n8\tMicroinches\n9\tMils\n10\tYards\n11\tAngstroms\n12\tNanometers\n13\tMicrons\n14\tDecimeters\n15\tDecameters\n16\tHectometers\n17\tGigameters\n18\tAstronomical Units\n19\tLight Years\n20\tParsecs
!INSUNITSDEFSOURCE|Integer|Registry|1 (imperial) or 4 (metric)
Sets source content units value. Valid range is 0 to 20. See INSUNITS for the actual meanings of the values 0 to 20.
!INSUNITSDEFTARGET|Integer|Registry|1 (imperial) or 4 (metric)
Sets target drawing units value. Valid range is 0 to 20. See INSUNITS for the actual meanings of the values 0 to 20.
!INTERSECTIONCOLOR|Integer|Drawing|257
Controls the color that is used for intersection polylines. Intersectiondisplay must be turned On in order for this value to matter.\n\n0\t\t\tByBlock\n1 to 255\t\tStandard ACI colors\n256\t\t\tByLayer\n257\t\t\tByEntity
!INTERSECTIONDISPLAY|Switch|Off
Controls the use of Intersectioncolor for displaying intersection polylines.\n\nOff\tDisplay of intersection polylines is not enabled\nOn\tDisplay of intersection ploylines is enabled
!ISAVEBAK|Integer|Registry|1
Improves the speed of incremental saves, especially for large drawings. ISAVEBAK controls the creation of a backup file (BAK). In Windows, copying the file data to create a BAK file for large drawings takes a major portion of the incremental save time.\n\n0\tNo BAK file is created (even for a full save)\n1\tA BAK file is created\n\nWARNING In some cases (such as a power failure in the middle of a save), it's possible that drawing data can be lost.
!ISAVEPERCENT|Integer|Registry|50
Determines the amount of wasted space tolerated in a drawing file. The value of ISAVEPERCENT is an integer between 0 and 100. The default value of 50 means that the estimate of wasted space within the file does not exceed 50 percent of the total file size. Wasted space is eliminated by periodic full saves. When the estimate exceeds 50 percent, the next save will be a full save. This resets the wasted space estimate to 0. If ISAVEPERCENT is set to 0, every save is a full save.
!ISOLINES|Integer|Drawing|4
Specifies the number of isolines per surface on objects. Valid integer values are from 0 to 2047.
#LASTANGLE|Real|Not saved|
Stores the end angle of the last arc entered relative to the XY plane of the current UCS for the current space.
!LASTPOINT|3D point|Not saved|0.0000,0.0000,0.0000
Stores the last point entered, expressed as a UCS coordinate for the current space; referenced by the at symbol (@) during keyboard entry.
#LASTPROMPT|String|Not saved|""
Stores the last string echoed to the command line. This string is identical to the last line seen at the command line and includes any user input.
!LAYOUTREGENCTL|Integer|Registry|2
Controls the display behavior of how a layout acts when switching to it.\n\n0\tEach time you switching to a layout tab, a regeneration occurs\n1\tModel and the last layout tab is cached into memory\n2\tInitial display of the tab is the only time that a regeneration occurs and any other time that the tab is activated it is read from cache
#LENSLENGTH|Real|Drawing|50.0000
Stores the length of the lens (in millimeters) used in perspective viewing for the current viewport.
!LIMCHECK|Integer|Drawing|0
Controls the creation of objects outside the drawing limits.\n\n0\tObjects can be created outside the limits\n1\tObjects cannot be created outside the limits
!LIMMAX|2D point|Drawing|12.0000,9.0000
Stores the upper-right drawing limits for the current space, expressed as a world coordinate. LIMMAX is read-only when paper space is active and the paper background or paper margins are displayed.
!LIMMIN|2D point|Drawing|0.0000,0.0000
Stores the lower-left drawing limits for the current space, expressed as a world coordinate. LIMMIN is read-only when paper space is active and the paper background or paper margins are displayed.
!LISPINIT|Integer|Registry|1
When single-document interface is enabled, specifies whether AutoLISP-defined functions and variables are preserved when you open a new drawing or whether they are valid in the current drawing session only.\n\n0\tAutoLISP functions and variables are preserved from drawing to drawing\n1\tAutoLISP functions and variables are valid in the current drawing only\n\nWhen SDIis set to 0, AutoLISP always behaves as if LISPINIT were set to 1. For information about the behavior of AutoLISP-defined functions and variables in a multiple-document interface, see "Designing For a Multiple Document Environment", in chapter 4, "Building Applications", in the Visual LISP Developer's Guide.
#LOCALE|String|Not saved|"ENU"
Displays the International Standards Organization (ISO) language code of the current AutoCAD version you're running.
#LOCALROOTPREFIX|String|Registry|"C:\Documents and Settings\<user name>\Local Settings\Application Data\Autodesk\AutoCAD 2005\R16.1\enu\"
Location that points to the Local Settings folder for AutoCAD on the machine or profile.
!LOGFILEMODE|Integer|Registry|0
Specifies whether the contents of the text window are written to a log file.\n\n0\tLog file is not maintained\n1\tLog file is maintained
#LOGFILENAME|String|Drawing|"C:\Documents and Settings\<user name>\Local Settings\Application Data\Autodesk\AutoCAD 2005\R16.1\Enu\Acad.log"
Specifies the path and name of the log file for the current drawing. The initial value varies depending on where you installed AutoCAD.
!LOGFILEPATH|String|Registry|"C:\Documents and Settings\<user name>\Local Settings\Application Data\Autodesk\AutoCAD 2005\R16.1\Enu\"
Specifies the path for the log files for all drawings in a session. You can also specify the path by using the OPTIONS command. The initial value varies depending on where you installed AutoCAD.
#LOGINNAME|String|Not saved|
Displays the user's name as configured or as input when AutoCAD is loaded. The maximum length for a login name is 30 characters.
!LTSCALE|Real|Drawing|1.0000
Sets the global linetype scale factor. The linetype scale factor cannot equal zero.
!LUNITS|Integer|Drawing|2
Sets linear units.\n\n1\tScientific\n2\tDecimal\n3\tEngineering\n4\tArchitectural\n5\tFractional
!LUPREC|Integer|Drawing|4
Sets the number of decimal places displayed for linear units in commands (except dimensioning commands), variables, and output. This includes coordinate display, and the AREA, DIST, ID, LIST, PROPERTIES, and UNITS commands.
!LWDEFAULT|Enum|Registry|25
Sets the value for the default lineweight. The default lineweight can be set to any valid lineweight value in hundredths of millimeters, including: 0, 5, 9, 13, 15, 18, 20, 25, 30, 35, 40, 50, 53, 60, 70, 80, 90, 100, 106, 120, 140, 158, 200, and 211.\n\nAll values must be entered in hundredths of millimeters. (Multiply a value by 2540 to convert values from inches to hundredths of millimeters.)
!LWDISPLAY|Integer|Drawing|0
Controls whether the lineweight is displayed on the Model or Layout tab. The setting is saved with each tab in the drawing.\n\n0 (off)\tLineweight is not displayed\n1 (on)\tLineweight is displayed
!LWUNITS|Integer|Registry|1
Controls whether lineweight units are displayed in inches or millimeters.\n\n0\tInches\n1\tMillimeters
!MAXACTVP|Integer|Drawing|64
Sets the maximum number of viewports that can be active at one time in the display. MAXACTVP has no effect on the number of viewports that are plotted.
!MAXSORT|Integer|Registry|1000
Sets the maximum number of symbol names or
⌨️ 快捷键说明
复制代码
Ctrl + C
搜索代码
Ctrl + F
全屏模式
F11
切换主题
Ctrl + Shift + D
显示快捷键
?
增大字号
Ctrl + =
减小字号
Ctrl + -