⭐ 欢迎来到虫虫下载站! | 📦 资源下载 📁 资源专辑 ℹ️ 关于我们
⭐ 虫虫下载站

📄 patternlayout.h

📁 log4cxx 0.10 unix下编译包
💻 H
字号:
/* * Licensed to the Apache Software Foundation (ASF) under one or more * contributor license agreements.  See the NOTICE file distributed with * this work for additional information regarding copyright ownership. * The ASF licenses this file to You under the Apache License, Version 2.0 * (the "License"); you may not use this file except in compliance with * the License.  You may obtain a copy of the License at * *      http://www.apache.org/licenses/LICENSE-2.0 * * Unless required by applicable law or agreed to in writing, software * distributed under the License is distributed on an "AS IS" BASIS, * WITHOUT WARRANTIES OR CONDITIONS OF ANY KIND, either express or implied. * See the License for the specific language governing permissions and * limitations under the License. */#ifndef _LOG4CXX_PATTERN_LAYOUT_H#define _LOG4CXX_PATTERN_LAYOUT_H#if defined(_MSC_VER)#pragma warning ( push )#pragma warning ( disable: 4231 4251 4275 4786 )#endif#include <log4cxx/layout.h>#include <log4cxx/pattern/loggingeventpatternconverter.h>#include <log4cxx/pattern/formattinginfo.h>#include <log4cxx/pattern/patternparser.h>namespace log4cxx{        /**        A flexible layout configurable with pattern string.        <p>The goal of this class is to #format a {@link        spi::LoggingEvent LoggingEvent} and return the results as a string.        The results depend on the <em>conversion pattern</em>.        <p>The conversion pattern is closely related to the conversion        pattern of the printf function in C. A conversion pattern is        composed of literal text and format control expressions called        <em>conversion specifiers</em>.        <p><i>You are free to insert any literal text within the conversion        pattern.</i>        <p>Each conversion specifier starts with a percent sign (\%) and is        followed by optional <em>format modifiers</em> and a <em>conversion        character</em>. The conversion character specifies the type of        data, e.g. logger, level, date, thread name. The format        modifiers control such things as field width, padding, left and        right justification. The following is a simple example.        <p>Let the conversion pattern be <b>"\%-5p [\%t]: \%m\%n"</b> and assume        that the log4cxx environment was set to use a PatternLayout. Then the        statements        <pre>        LoggerPtr root = Logger::getRoot();        root->debug("Message 1");        root->warn("Message 2");        </pre>        would yield the output        <pre>        DEBUG [main]: Message 1        WARN  [main]: Message 2        </pre>        <p>Note that there is no explicit separator between text and        conversion specifiers. The pattern parser knows when it has reached        the end of a conversion specifier when it reads a conversion        character. In the example above the conversion specifier        <b>\%-5p</b> means the level of the logging event should be left        justified to a width of five characters.        The recognized conversion characters are        <p>        <table border="1" CELLPADDING="8">        <tr>        <td align=center><b>Conversion Character</b></td>        <td align=center><b>Effect</b></td>        </tr>        <tr>        <td align=center><b>c</b></td>        <td>Used to output the logger of the logging event. The        logger conversion specifier can be optionally followed by        <em>precision specifier</em>, that is a decimal constant in        brackets.        <p>If a precision specifier is given, then only the corresponding        number of right most components of the logger name will be        printed. By default the logger name is printed in full.        <p>For example, for the logger name "a.b.c" the pattern        <b>\%c{2}</b> will output "b.c".        </td>        </tr>   <tr> <td align=center><b>d</b></td> <td>Used to output the date of         the logging event. The date conversion specifier may be         followed by a set of braces containing a         date and time pattern string compatible with java.text.SimpleDateFormat,         <em>ABSOLUTE</em>, <em>DATE</em> or <em>ISO8601</em>.         For example, <b>%d{HH:mm:ss,SSS}</b>,         <b>%d{dd&nbsp;MMM&nbsp;yyyy&nbsp;HH:mm:ss,SSS}</b> or         <b>%d{DATE}</b>.  If no date format specifier is given then         ISO8601 format is assumed.     </td>   </tr>        <tr>        <td align=center><b>F</b></td>        <td>Used to output the file name where the logging request was        issued.        </tr>        <tr>        <td align=center><b>l</b></td>        <td>Used to output location information of the caller which generated        the logging event.        </td>        </tr>        <tr>        <td align=center><b>L</b></td>        <td>Used to output the line number from where the logging request        was issued.        </tr>        <tr>        <td align=center><b>m</b></td>        <td>Used to output the application supplied message associated with        the logging event.</td>        </tr>        <tr>        <td align=center><b>n</b></td>        <td>Outputs the platform dependent line separator character or        characters.        <p>This conversion character offers practically the same        performance as using non-portable line separator strings such as        "\n", or "\r\n". Thus, it is the preferred way of specifying a        line separator.        </tr>        <tr>        <td align=center><b>p</b></td>        <td>Used to output the level of the logging event.</td>        </tr>        <tr>        <td align=center><b>r</b></td>        <td>Used to output the number of milliseconds elapsed since the start        of the application until the creation of the logging event.</td>        </tr>        <tr>        <td align=center><b>t</b></td>        <td>Used to output the name of the thread that generated the        logging event.</td>        </tr>        <tr>        <td align=center><b>x</b></td>        <td>Used to output the NDC (nested diagnostic context) associated        with the thread that generated the logging event.        </td>        </tr>        <tr>        <td align=center><b>X</b></td>        <td>        <p>Used to output the MDC (mapped diagnostic context) associated        with the thread that generated the logging event. The <b>X</b>        conversion character <em>must</em> be followed by the key for the        map placed between braces, as in <b>\%X{clientNumber}</b> where        <code>clientNumber</code> is the key. The value in the MDC        corresponding to the key will be output.</p>        <p>See MDC class for more details.        </p>        </td>        </tr>        <tr>        <td align=center><b>\%</b></td>        <td>The sequence \%\% outputs a single percent sign.        </td>        </tr>        </table>        <p>By default the relevant information is output as is. However,        with the aid of format modifiers it is possible to change the        minimum field width, the maximum field width and justification.        <p>The optional format modifier is placed between the percent sign        and the conversion character.        <p>The first optional format modifier is the <em>left justification        flag</em> which is just the minus (-) character. Then comes the        optional <em>minimum field width</em> modifier. This is a decimal        constant that represents the minimum number of characters to        output. If the data item requires fewer characters, it is padded on        either the left or the right until the minimum width is        reached. The default is to pad on the left (right justify) but you        can specify right padding with the left justification flag. The        padding character is space. If the data item is larger than the        minimum field width, the field is expanded to accommodate the        data. The value is never truncated.        <p>This behavior can be changed using the <em>maximum field        width</em> modifier which is designated by a period followed by a        decimal constant. If the data item is longer than the maximum        field, then the extra characters are removed from the        <em>beginning</em> of the data item and not from the end. For        example, it the maximum field width is eight and the data item is        ten characters long, then the first two characters of the data item        are dropped. This behavior deviates from the printf function in C        where truncation is done from the end.        <p>Below are various format modifier examples for the logger        conversion specifier.        <p>        <TABLE BORDER=1 CELLPADDING=8>        <tr>        <td align=center><b>Format modifier</b></td>        <td align=center><b>left justify</b></td>        <td align=center><b>minimum width</b></td>        <td align=center><b>maximum width</b></td>        <td align=center><b>comment</b></td>        </tr>        <tr>        <td align=center>\%20c</td>        <td align=center>false</td>        <td align=center>20</td>        <td align=center>none</td>        <td>Left pad with spaces if the logger name is less than 20        characters long.        <tr> <td align=center>\%-20c</td> <td align=center>true</td> <td        align=center>20</td> <td align=center>none</td> <td>Right pad with        spaces if the logger name is less than 20 characters long.        <tr>        <td align=center>\%.30c</td>        <td align=center>NA</td>        <td align=center>none</td>        <td align=center>30</td>        <td>Truncate from the beginning if the logger name is longer than 30        characters.        <tr>        <td align=center>\%20.30c</td>        <td align=center>false</td>        <td align=center>20</td>        <td align=center>30</td>        <td>Left pad with spaces if the logger name is shorter than 20        characters. However, if logger name is longer than 30 characters,        then truncate from the beginning.        <tr>        <td align=center>\%-20.30c</td>        <td align=center>true</td>        <td align=center>20</td>        <td align=center>30</td>        <td>Right pad with spaces if the logger name is shorter than 20        characters. However, if logger name is longer than 30 characters,        then truncate from the beginning.        </table>        <p>Below are some examples of conversion patterns.        <p><b>\%r [\%t] \%-5p \%c \%x - \%m\n</b>        <p>This is essentially the TTCC layout.        <p><b>\%-6r [\%15.15t] \%-5p \%30.30c \%x - \%m\n</b>        <p>Similar to the TTCC layout except that the relative time is        right padded if less than 6 digits, thread name is right padded if        less than 15 characters and truncated if longer and the logger        name is left padded if shorter than 30 characters and truncated if        longer.        <p>The above text is largely inspired from Peter A. Darnell and        Philip E. Margolis' highly recommended book "C -- a Software        Engineering Approach", ISBN 0-387-97389-3.        */        class LOG4CXX_EXPORT PatternLayout : public Layout        {                 /**                  * Conversion pattern.                  */                LogString conversionPattern;                /**                 * Pattern converters.                 */                LOG4CXX_LIST_DEF(LoggingEventPatternConverterList, log4cxx::pattern::LoggingEventPatternConverterPtr);                LoggingEventPatternConverterList patternConverters;               /**                * Field widths and alignment corresponding to pattern converters.                */                LOG4CXX_LIST_DEF(FormattingInfoList, log4cxx::pattern::FormattingInfoPtr);                FormattingInfoList patternFields;        public:                DECLARE_LOG4CXX_OBJECT(PatternLayout)                BEGIN_LOG4CXX_CAST_MAP()                        LOG4CXX_CAST_ENTRY(PatternLayout)                        LOG4CXX_CAST_ENTRY_CHAIN(Layout)                END_LOG4CXX_CAST_MAP()                /**                Does nothing                */                PatternLayout();                /**                Constructs a PatternLayout using the supplied conversion pattern.                */                PatternLayout(const LogString& pattern);                /**                Set the <b>ConversionPattern</b> option. This is the string which                controls formatting and consists of a mix of literal content and                conversion specifiers.                */                void setConversionPattern(const LogString& conversionPattern);                /**                Returns the value of the <b>ConversionPattern</b> option.                */                inline LogString getConversionPattern() const                        { return conversionPattern; }                /**                Call createPatternParser                */                virtual void activateOptions(log4cxx::helpers::Pool& p);                virtual void setOption(const LogString& option, const LogString& value);                /**                The PatternLayout does not handle the throwable contained within                {@link spi::LoggingEvent LoggingEvents}. Thus, it returns                <code>true</code>.                */                virtual bool ignoresThrowable() const                        { return true; }                /**                Produces a formatted string as specified by the conversion pattern.                */                virtual void format(LogString& output,                     const spi::LoggingEventPtr& event, log4cxx::helpers::Pool& pool) const;        protected:                virtual log4cxx::pattern::PatternMap getFormatSpecifiers();        };      LOG4CXX_PTR_DEF(PatternLayout);}  // namespace log4cxx#if defined(_MSC_VER)#pragma warning ( pop )#endif#endif //_LOG4CXX_PATTERN_LAYOUT_H

⌨️ 快捷键说明

复制代码 Ctrl + C
搜索代码 Ctrl + F
全屏模式 F11
切换主题 Ctrl + Shift + D
显示快捷键 ?
增大字号 Ctrl + =
减小字号 Ctrl + -