📄 alarmconfiguration.mib
字号:
-- File Name : AlarmConfiguration.mib-- Date : Wed Jul 16 08:37:19 CST 2008-- Author : AdventNet Agent Toolkit C Edition - MibEditor 6--
-- AlarmConfiguration.mib
-- MIB generated by MG-SOFT Visual MIB Builder Version 6.0 Build 88
-- Wednesday, July 12, 2006 at 18:01:44
--
-- AlarmConfiguration.mib
-- MIB generated by MG-SOFT Visual MIB Builder Version 6.0 Build 88
-- Sunday, June 25, 2006 at 11:42:12
--
-- AlarmConfiguration.mib
-- MIB generated by MG-SOFT Visual MIB Builder Version 6.0 Build 88
-- Wednesday, April 26, 2006 at 15:52:13
--
-- AlarmConfiguration.mib
-- MIB generated by MG-SOFT Visual MIB Builder Version 6.0 Build 88
-- Wednesday, April 26, 2006 at 15:01:58
--
-- AlarmConfiguration.mib
-- MIB generated by MG-SOFT Visual MIB Builder Version 6.0 Build 88
-- Tuesday, January 10, 2006 at 15:24:31
--
-- AlarmConfiguration.mib
-- MIB generated by MG-SOFT Visual MIB Builder Version 6.0 Build 88
-- Tuesday, January 03, 2006 at 18:42:11
--
FORTO-ALARM-CONFIGURATION-MIB DEFINITIONS ::= BEGIN IMPORTS fortoPrivate, FortoOLTIdIndex FROM FORTO-MIB ifIndex FROM IF-MIB Counter32, Counter64, OBJECT-TYPE, MODULE-IDENTITY, NOTIFICATION-TYPE, enterprises, Integer32 FROM SNMPv2-SMI; fortoAlarmConfiguration MODULE-IDENTITY LAST-UPDATED "190502081355Z" ORGANIZATION "FORTO LTD" CONTACT-INFO " EMANUEL GRINSPUN" DESCRIPTION "The MIB for ALARM SET UP " REVISION "190502081355Z" DESCRIPTION "Revisions made by the Interfaces MIB WG." ::= { fortoPrivate 13 } fortoAlarmSetting OBJECT IDENTIFIER ::= { fortoAlarmConfiguration 1 } fortoAlarmNotifyObjects OBJECT IDENTIFIER ::= { fortoAlarmConfiguration 2 } fortoAlarmNotification OBJECT IDENTIFIER ::= { fortoAlarmConfiguration 3 } alarmConfigurationTable OBJECT-TYPE SYNTAX SEQUENCE OF AlarmConfigurationEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table configures alarm event generation thresholds, overriding previous / default configuration." ::= { fortoAlarmSetting 1 } alarmConfigurationEntry OBJECT-TYPE SYNTAX AlarmConfigurationEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry containing management information applicable
to a particular OLT. The information is for all OLT versions.
The index is the ifIndex of the OLT and ONU device." INDEX { ifIndex } ::= { alarmConfigurationTable 1 } AlarmConfigurationEntry ::= SEQUENCE { alarmConfigurationOLTApply INTEGER, alarmConfigurationBERActivation INTEGER, alarmConfigurationBERDirection INTEGER, alarmConfigurationBERThreshold OCTET STRING, alarmConfigurationBERMinimumErrorThreshold Integer32, alarmConfigurationFERActivation INTEGER, alarmConfigurationFERDirection INTEGER, alarmConfigurationFERThreshold OCTET STRING, alarmConfigurationFERMinimumErrorThreshold Integer32, alarmConfigurationSoftwareErrorActivation INTEGER, alarmConfigurationLocalLinkFaultActivation INTEGER, alarmConfigurationDyingGaspActivation INTEGER, alarmConfigurationCriticalEventActivation INTEGER, alarmConfigurationRemoteStableActivation INTEGER, alarmConfigurationLocalStableActivation INTEGER, alarmConfigurationOAMVendorSpecificActivation INTEGER, alarmConfigurationErroredSymbolPeriodActivation INTEGER, alarmConfigurationErroredSymbolPeriodWindow OCTET STRING, alarmConfigurationErroredSymbolPeriodThreshold OCTET STRING, alarmConfigurationErroredFrameActivation INTEGER, alarmConfigurationErroredFrameWindow Integer32, alarmConfigurationErroredFrameThreshold Integer32, alarmConfigurationErroredFramePeriodActivation INTEGER, alarmConfigurationErroredFramePeriodWindow Integer32, alarmConfigurationErroredFramePeriodThreshold Integer32, alarmConfigurationErroredFrameSecondSummaryActivation INTEGER, alarmConfigurationErroredFrameSecondSummaryWindow Integer32, alarmConfigurationErroredFrameSecondSummaryThreshold Integer32, alarmConfigurationONURegistrationError INTEGER, alarmConfigurationOAMLinkDisconnection INTEGER, alarmConfigurationBadEncryptionKey INTEGER, alarmConfigurationLLIDMismatch INTEGER, alarmConfigurationLLIDMismatchThreshold Integer32, alarmConfigurationTooManyONUsRegistration INTEGER, alarmConfigurationPortBER Integer32, alarmConfigurationPortBERDirection Integer32, alarmConfigurationPortBERThreshold OCTET STRING, alarmConfigurationPortBERMinimumErrorThreshold Integer32 } alarmConfigurationOLTApply OBJECT-TYPE SYNTAX INTEGER { this ( 0 ) , all ( 1 ) } MAX-ACCESS read-write STATUS current DESCRIPTION "Apply this setting to all OLT = 1 " ::= { alarmConfigurationEntry 1 } alarmConfigurationBERActivation OBJECT-TYPE SYNTAX INTEGER { disable ( 0 ) , enable ( 1 ) } MAX-ACCESS read-write STATUS current DESCRIPTION "Disable alarm monitoring for the specified alarm = 0
Enable alarm monitoring for the specified alarm = 1
NOTE for SNMP SET : this leaf must be used together with alarmConfigurationBERDirection,
alarmConfigurationBERThreshold and alarmConfigurationBERMinimumErrorThreshold leaves." ::= { alarmConfigurationEntry 2 } alarmConfigurationBERDirection OBJECT-TYPE SYNTAX INTEGER { up ( 0 ) , down ( 1 ) , both ( 2 ) } MAX-ACCESS read-write STATUS current DESCRIPTION "Traffic direction to monitor for BER alarm.
Only one of the allowed values can be applied to a single OLT.
Uplink (downlink BER is disabled) = 0
Downlink (uplink BER is disabled) = 1
Downlink and uplink = 2
NOTE for SNMP SET : this leaf must be used together with alarmConfigurationBERActivation
alarmConfigurationBERThreshold and alarmConfigurationBERMinimumErrorThreshold leaves.
" ::= { alarmConfigurationEntry 3 } alarmConfigurationBERThreshold OBJECT-TYPE SYNTAX OCTET STRING ( SIZE ( 1 .. 12 ) ) MAX-ACCESS read-write STATUS current DESCRIPTION "Normal BER threshold
0 - 1 (not including 0), ten digit precision
NOTE for SNMP SET : this leaf must be used together with alarmConfigurationBERActivation
alarmConfigurationBERDirection and alarmConfigurationBERMinimumErrorThreshold leaves.
" ::= { alarmConfigurationEntry 4 } alarmConfigurationBERMinimumErrorThreshold OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The minimal number of error bytes required for BER alarm
NOTE for SNMP SET : this leaf must be used together with alarmConfigurationBERActivation
alarmConfigurationBERDirection and alarmConfigurationBERThreshold leaves.
" ::= { alarmConfigurationEntry 5 } alarmConfigurationFERActivation OBJECT-TYPE SYNTAX INTEGER { disable ( 0 ) , enable ( 1 ) } MAX-ACCESS read-write STATUS current DESCRIPTION "Disable alarm monitoring for the specified alarm = 0
Enable alarm monitoring for the specified alarm = 1
NOTE for SNMP SET : this leaf must be used together with alarmConfigurationFERDirection,
alarmConfigurationFERThreshold and alarmConfigurationFERMinimumErrorThreshold leaves." ::= { alarmConfigurationEntry 6 } alarmConfigurationFERDirection OBJECT-TYPE SYNTAX INTEGER { up ( 0 ) , down ( 1 ) , both ( 2 ) } MAX-ACCESS read-write STATUS current DESCRIPTION "Traffic direction to monitor for BER alarm.
Only one of the allowed values can be applied to a single OLT.
Uplink (downlink FER is disabled) = 0
Downlink (uplink FER is disabled) = 1
Downlink and uplink = 2
NOTE for SNMP SET : this leaf must be used together with alarmConfigurationFERActivation
alarmConfigurationFERThreshold and alarmConfigurationFERMinimumErrorThreshold leaves." ::= { alarmConfigurationEntry 7 } alarmConfigurationFERThreshold OBJECT-TYPE SYNTAX OCTET STRING ( SIZE ( 1 .. 12 ) ) MAX-ACCESS read-write STATUS current DESCRIPTION "Normal FER threshold
0 - 1 (not including 0), ten digit precision
NOTE for SNMP SET : this leaf must be used together with alarmConfigurationFERActivation
alarmConfigurationFERDirection and alarmConfigurationFERMinimumErrorThreshold leaves." ::= { alarmConfigurationEntry 8 } alarmConfigurationFERMinimumErrorThreshold OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The minimal number of error bytes required for FER alarm
NOTE for SNMP SET : this leaf must be used together with alarmConfigurationFERActivation
alarmConfigurationFERDirection and alarmConfigurationFERThreshold leaves." ::= { alarmConfigurationEntry 9 } alarmConfigurationSoftwareErrorActivation OBJECT-TYPE SYNTAX INTEGER { disable ( 0 ) , enable ( 1 ) } MAX-ACCESS read-write STATUS current DESCRIPTION "Software Errors
NOTE for SNMP SET : this leaf must be used together with alarmConfigurationOLTApply leaf.
" DEFVAL { 1 } ::= { alarmConfigurationEntry 10 } alarmConfigurationLocalLinkFaultActivation OBJECT-TYPE SYNTAX INTEGER { disable ( 0 ) , enable ( 1 ) } MAX-ACCESS read-write STATUS current DESCRIPTION "Local Link Fault
" DEFVAL { 1 } ::= { alarmConfigurationEntry 11 } alarmConfigurationDyingGaspActivation OBJECT-TYPE SYNTAX INTEGER { disable ( 0 ) , enable ( 1 ) } MAX-ACCESS read-write STATUS current DESCRIPTION "Dying Gasp
" DEFVAL { 1 } ::= { alarmConfigurationEntry 12 } alarmConfigurationCriticalEventActivation OBJECT-TYPE SYNTAX INTEGER { disable ( 0 ) , enable ( 1 ) } MAX-ACCESS read-write STATUS current DESCRIPTION "Critical Events
" DEFVAL { 1 } ::= { alarmConfigurationEntry 13 } alarmConfigurationRemoteStableActivation OBJECT-TYPE SYNTAX INTEGER { disable ( 0 ) , enable ( 1 ) } MAX-ACCESS read-write STATUS current DESCRIPTION "Remote stable " DEFVAL { 1 } ::= { alarmConfigurationEntry 14 } alarmConfigurationLocalStableActivation OBJECT-TYPE SYNTAX INTEGER { disable ( 0 ) , enable ( 1 ) } MAX-ACCESS read-write STATUS current DESCRIPTION "Local Stable
" DEFVAL { 1 } ::= { alarmConfigurationEntry 15 } alarmConfigurationOAMVendorSpecificActivation OBJECT-TYPE SYNTAX INTEGER { disable ( 0 ) , enable ( 1 ) } MAX-ACCESS read-write STATUS current DESCRIPTION "OAM Vendor Specific
" DEFVAL { 1 } ::= { alarmConfigurationEntry 16 } alarmConfigurationErroredSymbolPeriodActivation OBJECT-TYPE SYNTAX INTEGER { disable ( 0 ) , enable ( 1 ) } MAX-ACCESS read-write STATUS current DESCRIPTION "Error Symbol Period
NOTE for SNMP SET : this leaf must be used together with alarmConfigurationErroredSymbolPeriodWindow
and alarmConfigurationErroredSymbolPeriodThreshold leaves." DEFVAL { 1 } ::= { alarmConfigurationEntry 17 } alarmConfigurationErroredSymbolPeriodWindow OBJECT-TYPE SYNTAX OCTET STRING ( SIZE ( 0 .. 8 ) ) MAX-ACCESS read-write STATUS current DESCRIPTION "The number of symbols in the period
NOTE for SNMP SET : this leaf must be used together with alarmConfigurationErroredSymbolPeriodActivation
and alarmConfigurationErroredSymbolPeriodThreshold leaves." ::= { alarmConfigurationEntry 18 } alarmConfigurationErroredSymbolPeriodThreshold OBJECT-TYPE SYNTAX OCTET STRING ( SIZE ( 0 .. 8 ) ) MAX-ACCESS read-write STATUS current DESCRIPTION "Number of errored symbols in the period that is required to be equal
to or greater than in order for the alarm to be generated
NOTE for SNMP SET : this leaf must be used together with alarmConfigurationErroredSymbolPeriodActivation
and alarmConfigurationErroredSymbolPeriodWindow leaves." ::= { alarmConfigurationEntry 19 } alarmConfigurationErroredFrameActivation OBJECT-TYPE SYNTAX INTEGER { disable ( 0 ) , enable ( 1 ) } MAX-ACCESS read-write