          RFC1213-MIB DEFINITIONS ::= BEGIN

          IMPORTS
                  mgmt, NetworkAddress, IpAddress, Counter, Gauge,
                          TimeTicks
                      FROM RFC1155-SMI
                  OBJECT-TYPE
                          FROM RFC-1212;

          mgmt         OBJECT IDENTIFIER ::= { iso org(3) dod(6) internet(1) mgmt(2) }
          directory    OBJECT IDENTIFIER ::= { internet 1 }
          experimental OBJECT IDENTIFIER ::= { internet 3 }
          private      OBJECT IDENTIFIER ::= { internet 4 }
          enterprises  OBJECT IDENTIFIER ::= { private 1 }

          --  This MIB module uses the extended OBJECT-TYPE macro as
          --  defined in [14];


          --  MIB-II (same prefix as MIB-I)

          mib-2      OBJECT IDENTIFIER ::= { mgmt 1 }

          -- textual conventions

           DisplayString ::=
               OCTET STRING
          -- This data type is used to model textual information taken
          -- from the NVT ASCII character set.  By convention, objects
          -- with this syntax are declared as having
          --
                (SIZE (0..255))

           PhysAddress ::=
               OCTET STRING
          -- This data type is used to model media addresses.  For many
          -- types of media, this will be in a binary representation.
          -- For example, an ethernet address would be represented as
          -- a string of 6 octets.


          -- groups in MIB-II

          system       OBJECT IDENTIFIER ::= { mib-2 1 }

          interfaces   OBJECT IDENTIFIER ::= { mib-2 2 }

          at           OBJECT IDENTIFIER ::= { mib-2 3 }

          ip           OBJECT IDENTIFIER ::= { mib-2 4 }

          icmp         OBJECT IDENTIFIER ::= { mib-2 5 }

          tcp          OBJECT IDENTIFIER ::= { mib-2 6 }

          udp          OBJECT IDENTIFIER ::= { mib-2 7 }

          egp          OBJECT IDENTIFIER ::= { mib-2 8 }

          -- historical (some say hysterical)
          -- cmot      OBJECT IDENTIFIER ::= { mib-2 9 }

          transmission OBJECT IDENTIFIER ::= { mib-2 10 }

          snmp         OBJECT IDENTIFIER ::= { mib-2 11 }


          -- the System group

          -- Implementation of the System group is mandatory for all
          -- systems.  If an agent is not configured to have a value
          -- for any of these variables, a string of length 0 is
          -- returned.

          sysDescr OBJECT-TYPE
              SYNTAX  DisplayString (SIZE (0..255))
              ACCESS  read-only
              STATUS  mandatory
              DEFVAL  "Test Agent Simulator"  
              DESCRIPTION
                      "A textual description of the entity.  This value
                      should include the full name and version
                      identification of the system's hardware type,
                      software operating-system, and networking
                      software.  It is mandatory that this only contain
                      printable ASCII characters."
              ::= { system 1 }

          sysObjectID OBJECT-TYPE
              SYNTAX  OBJECT IDENTIFIER
              ACCESS  read-only
              STATUS  mandatory
              DESCRIPTION
                      "The vendor's authoritative identification of the
                      network management subsystem contained in the
                      entity.  This value is allocated within the SMI
                      enterprises subtree (1.3.6.1.4.1) and provides an
                      easy and unambiguous means for determining `what
                      kind of box' is being managed.  For example, if
                      vendor `Flintstones, Inc.' was assigned the
                      subtree 1.3.6.1.4.1.4242, it could assign the
                      identifier 1.3.6.1.4.1.4242.1.1 to its `Fred
                      Router'."
              ::= { system 2 }

          sysUpTime OBJECT-TYPE
              SYNTAX  TimeTicks
              ACCESS  read-only
              STATUS  mandatory
              DESCRIPTION
                      "The time (in hundredths of a second) since the
                      network management portion of the system was last
                      re-initialized."
              ::= { system 3 }

          sysContact OBJECT-TYPE
              SYNTAX  DisplayString (SIZE (0..255))
              ACCESS  read-write
              STATUS  mandatory
              DESCRIPTION
                      "The textual identification of the contact person
                      for this managed node, together with information
                      on how to contact this person."
              ::= { system 4 }

          sysName OBJECT-TYPE
              SYNTAX  DisplayString (SIZE (0..255))
              ACCESS  read-write
              STATUS  mandatory
              DESCRIPTION
                      "An administratively-assigned name for this
                      managed node.  By convention, this is the node's
                      fully-qualified domain name."
              ::= { system 5 }

          sysLocation OBJECT-TYPE
              SYNTAX  DisplayString (SIZE (0..255))
              ACCESS  read-write
              STATUS  mandatory
              DESCRIPTION
                      "The physical location of this node (e.g.,
                      `telephone closet, 3rd floor')."
              ::= { system 6 }

          sysServices OBJECT-TYPE
              SYNTAX  INTEGER (0..127)
              ACCESS  read-only
              STATUS  mandatory
              DESCRIPTION
                      "A value which indicates the set of services that
                      this entity primarily offers.

                      The value is a sum.  This sum initially takes the
                      value zero, Then, for each layer, L, in the range
                      1 through 7, that this node performs transactions
                      for, 2 raised to (L - 1) is added to the sum.  For
                      example, a node which performs primarily routing
                      functions would have a value of 4 (2^(3-1)).  In
                      contrast, a node which is a host offering
                      application services would have a value of 72
                      (2^(4-1) + 2^(7-1)).  Note that in the context of
                      the Internet suite of protocols, values should be
                      calculated accordingly:

                           layer  functionality
                               1  physical (e.g., repeaters)
                               2  datalink/subnetwork (e.g., bridges)
                               3  internet (e.g., IP gateways)
                               4  end-to-end  (e.g., IP hosts)
                               7  applications (e.g., mail relays)

                      For systems including OSI protocols, layers 5 and
                      6 may also be counted."
              ::= { system 7 }

          -- the Interfaces group

          -- Implementation of the Interfaces group is mandatory for
          -- all systems.

          ifNumber OBJECT-TYPE
              SYNTAX  INTEGER
              ACCESS  read-only
              STATUS  mandatory
              DEFVAL 1
              DESCRIPTION
                      "The number of network interfaces (regardless of
                      their current state) present on this system."
              ::= { interfaces 1 }


          -- the Interfaces table

          -- The Interfaces table contains information on the entity's
          -- interfaces.  Each interface is thought of as being
          -- attached to a `subnetwork'.  Note that this term should
          -- not be confused with `subnet' which refers to an
          -- addressing partitioning scheme used in the Internet suite
          -- of protocols.

          ifTable OBJECT-TYPE
              SYNTAX  SEQUENCE OF IfEntry
              ACCESS  not-accessible
              STATUS  mandatory
              DESCRIPTION
                      "A list of interface entries.  The number of
                      entries is given by the value of ifNumber."
              ::= { interfaces 2 }

          ifEntry OBJECT-TYPE
              SYNTAX  IfEntry
              ACCESS  not-accessible
              STATUS  mandatory
              DESCRIPTION
                      "An interface entry containing objects at the
                      subnetwork layer and below for a particular
                      interface."
              INDEX   { ifIndex }
              ::= { ifTable 1 }

          IfEntry ::=
              SEQUENCE {
                  ifIndex
                      INTEGER,
                  ifDescr
                      DisplayString,
                  ifType
                      INTEGER,
                  ifMtu
                      INTEGER,
                  ifSpeed
                      Gauge,
                  ifPhysAddress
                      PhysAddress,
                  ifAdminStatus
                      INTEGER,
                  ifOperStatus
                      INTEGER,
                  ifLastChange
                      TimeTicks,
                  ifInOctets
                      Counter,
                  ifInUcastPkts
                      Counter,
                  ifInNUcastPkts
                      Counter,
                  ifInDiscards
                      Counter,
                  ifInErrors
                      Counter,
                  ifInUnknownProtos
                      Counter,
                  ifOutOctets
                      Counter,
                  ifOutUcastPkts
                      Counter,
                  ifOutNUcastPkts
                      Counter,
                  ifOutDiscards
                      Counter,
                  ifOutErrors
                      Counter,
                  ifOutQLen
                      Gauge,
                  ifSpecific
                      OBJECT IDENTIFIER
              }

          ifIndex OBJECT-TYPE
              SYNTAX  INTEGER
              ACCESS  read-only
              STATUS  mandatory
              DESCRIPTION
                      "A unique value for each interface.  Its value
                      ranges between 1 and the value of ifNumber.  The
                      value for each interface must remain constant at
                      least from one re-initialization of the entity's
                      network management system to the next re-
                      initialization."
              ::= { ifEntry 1 }

          ifDescr OBJECT-TYPE
              SYNTAX  DisplayString (SIZE (0..255))
              ACCESS  read-only
              STATUS  mandatory
              DEFVAL  "Test Interface"
              DESCRIPTION
                      "A textual string containing information about the
                      interface.  This string should include the name of
                      the manufacturer, the product name and the version
                      of the hardware interface."
              ::= { ifEntry 2 }

          ifType OBJECT-TYPE
              SYNTAX  INTEGER {
                          other(1),          -- none of the following
                          regular1822(2),
                          hdh1822(3),
                          ddn-x25(4),
                          rfc877-x25(5),
                          ethernet-csmacd(6),
                          iso88023-csmacd(7),
                          iso88024-tokenBus(8),
                          iso88025-tokenRing(9),
                          iso88026-man(10),
                          starLan(11),
                          proteon-10Mbit(12),
                          proteon-80Mbit(13),
                          hyperchannel(14),
                          fddi(15),
                          lapb(16),
                          sdlc(17),
                          ds1(18),           -- T-1
                          e1(19),            -- european equiv. of T-1
                          basicISDN(20),
                          primaryISDN(21),   -- proprietary serial
                          propPointToPointSerial(22),
                          ppp(23),