📄 if-mib.mib
字号:
IF-MIB DEFINITIONS ::= BEGIN
IMPORTS
MODULE-IDENTITY, OBJECT-TYPE, Counter32, Gauge32, Counter64,
Integer32, TimeTicks, mib-2,
NOTIFICATION-TYPE FROM SNMPv2-SMI
TEXTUAL-CONVENTION, DisplayString,
PhysAddress, TruthValue, RowStatus,
TimeStamp, AutonomousType, TestAndIncr FROM SNMPv2-TC
MODULE-COMPLIANCE, OBJECT-GROUP FROM SNMPv2-CONF
snmpTraps FROM SNMPv2-MIB
IANAifType FROM IANAifType-MIB;
ifMIB MODULE-IDENTITY
LAST-UPDATED "9611031355Z"
ORGANIZATION "IETF Interfaces MIB Working Group"
CONTACT-INFO
" Keith McCloghrie
Cisco Systems, Inc.
170 West Tasman Drive
San Jose, CA 95134-1706
US
408-526-5260
kzm@cisco.com"
DESCRIPTION
"The MIB module to describe generic objects for
network interface sub-layers. This MIB is an updated
version of MIB-II's ifTable, and incorporates the
extensions defined in RFC 1229."
REVISION "9602282155Z"
DESCRIPTION
"Revisions made by the Interfaces MIB WG."
REVISION "9311082155Z"
DESCRIPTION
"Initial revision, published as part of RFC 1573."
::= { mib-2 31 }
ifMIBObjects OBJECT IDENTIFIER ::= { ifMIB 1 }
interfaces OBJECT IDENTIFIER ::= { mib-2 2 }
OwnerString ::= TEXTUAL-CONVENTION
DISPLAY-HINT "255a"
STATUS current
DESCRIPTION
"This data type is used to model an administratively
assigned name of the owner of a resource. This
information is taken from the NVT ASCII character set.
It is suggested that this name contain one or more of
the following: ASCII form of the manager station's
transport address, management station name (e.g.,
domain name), network management personnel's name,
location, or phone number. In some cases the agent
itself will be the owner of an entry. In these cases,
this string shall be set to a string starting with
'agent'."
SYNTAX OCTET STRING (SIZE(0..255))
-- InterfaceIndex contains the semantics of ifIndex and
-- should be used for any objects defined on other mib
-- modules that need these semantics.
InterfaceIndex ::= TEXTUAL-CONVENTION
DISPLAY-HINT "d"
STATUS current
DESCRIPTION
"A unique value, greater than zero, for each interface
or interface sub-layer in the managed system. It is
recommended that values are assigned contiguously
starting from 1. The value for each interface sub-
layer must remain constant at least from one re-
initialization of the entity's network management
system to the next re-initialization."
SYNTAX Integer32 (1..2147483647)
InterfaceIndexOrZero ::= TEXTUAL-CONVENTION
DISPLAY-HINT "d"
STATUS current
DESCRIPTION
"This textual convention is an extension of the
InterfaceIndex convention. The latter defines a
greater than zero value used to identify an interface
or interface sub-layer in the managed system. This
extension permits the additional value of zero. the
value zero is object-specific and must therefore be
defined as part of the description of any object which
uses this syntax. Examples of the usage of zero might
include situations where interface was unknown, or
when none or all interfaces need to be referenced."
SYNTAX Integer32 (0..2147483647)
ifNumber OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of network interfaces (regardless of their
current state) present on this system."
::= { interfaces 1 }
ifTableLastChange OBJECT-TYPE
SYNTAX TimeTicks
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of sysUpTime at the time of the last
creation or deletion of an entry in the ifTable. If
the number of entries has been unchanged since the
last re-initialization of the local network management
subsystem, then this object contains a zero value."
::= { ifMIBObjects 5 }
-- the Interfaces table
-- The Interfaces table contains information on the entity's
-- interfaces. Each sub-layer below the internetwork-layer
-- of a network interface is considered to be an interface.
ifTable OBJECT-TYPE
SYNTAX SEQUENCE OF IfEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A list of interface entries. The number of entries
is given by the value of ifNumber."
::= { interfaces 2 }
ifEntry OBJECT-TYPE
SYNTAX IfEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry containing management information applicable
to a particular interface."
INDEX { ifIndex }
::= { ifTable 1 }
IfEntry ::=
SEQUENCE {
ifIndex InterfaceIndex,
ifDescr DisplayString,
ifType IANAifType,
ifMtu Integer32,
ifSpeed Gauge32,
ifPhysAddress PhysAddress,
ifAdminStatus INTEGER,
ifOperStatus INTEGER,
ifLastChange TimeTicks,
ifInOctets Counter32,
ifInUcastPkts Counter32,
ifInNUcastPkts Counter32, -- deprecated
ifInDiscards Counter32,
ifInErrors Counter32,
ifInUnknownProtos Counter32,
ifOutOctets Counter32,
ifOutUcastPkts Counter32,
ifOutNUcastPkts Counter32, -- deprecated
ifOutDiscards Counter32,
ifOutErrors Counter32,
ifOutQLen Gauge32, -- deprecated
ifSpecific OBJECT IDENTIFIER -- deprecated
}
ifIndex OBJECT-TYPE
SYNTAX InterfaceIndex
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A unique value, greater than zero, for each
interface. It is recommended that values are assigned
contiguously starting from 1. The value for each
interface sub-layer must remain constant at least from
one re-initialization of the entity's network
management system to the next re-initialization."
::= { ifEntry 1 }
ifDescr OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A textual string containing information about the
interface. This string should include the name of the
manufacturer, the product name and the version of the
interface hardware/software."
::= { ifEntry 2 }
ifType OBJECT-TYPE
SYNTAX IANAifType
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The type of interface. Additional values for ifType
are assigned by the Internet Assigned Numbers
Authority (IANA), through updating the syntax of the
IANAifType textual convention."
::= { ifEntry 3 }
ifMtu OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The size of the largest packet which can be
sent/received on the interface, specified in octets.
For interfaces that are used for transmitting network
datagrams, this is the size of the largest network
datagram that can be sent on the interface."
::= { ifEntry 4 }
ifSpeed OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"An estimate of the interface's current bandwidth in
bits per second. For interfaces which do not vary in
bandwidth or for those where no accurate estimation
can be made, this object should contain the nominal
bandwidth. If the bandwidth of the interface is
greater than the maximum value reportable by this
object then this object should report its maximum
value (4,294,967,295) and ifHighSpeed must be used to
report the interace's speed. For a sub-layer which
has no concept of bandwidth, this object should be
zero."
::= { ifEntry 5 }
ifPhysAddress OBJECT-TYPE
SYNTAX PhysAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The interface's address at its protocol sub-layer.
For example, for an 802.x interface, this object
normally contains a MAC address. The interface's
media-specific MIB must define the bit and byte
ordering and the format of the value of this object.
For interfaces which do not have such an address
(e.g., a serial line), this object should contain an
octet string of zero length."
::= { ifEntry 6 }
ifAdminStatus OBJECT-TYPE
SYNTAX INTEGER {
up(1), -- ready to pass packets
down(2),
testing(3) -- in some test mode
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The desired state of the interface. The testing(3)
state indicates that no operational packets can be
passed. When a managed system initializes, all
interfaces start with ifAdminStatus in the down(2)
state. As a result of either explicit management
action or per configuration information retained by
the managed system, ifAdminStatus is then changed to
either the up(1) or testing(3) states (or remains in
the down(2) state)."
::= { ifEntry 7 }
ifOperStatus OBJECT-TYPE
SYNTAX INTEGER {
up(1), -- ready to pass packets
down(2),
testing(3), -- in some test mode
unknown(4), -- status can not be determined
-- for some reason.
dormant(5),
notPresent(6), -- some component is missing
lowerLayerDown(7) -- down due to state of
-- lower-layer interface(s)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The current operational state of the interface. The
testing(3) state indicates that no operational packets
can be passed. If ifAdminStatus is down(2) then
ifOperStatus should be down(2). If ifAdminStatus is
changed to up(1) then ifOperStatus should change to
up(1) if the interface is ready to transmit and
receive network traffic; it should change to
dormant(5) if the interface is waiting for external
actions (such as a serial line waiting for an incoming
connection); it should remain in the down(2) state if
and only if there is a fault that prevents it from
going to the up(1) state; it should remain in the
notPresent(6) state if the interface has missing
(typically, hardware) components."
::= { ifEntry 8 }
ifLastChange OBJECT-TYPE
SYNTAX TimeTicks
MAX-ACCESS read-only
⌨️ 快捷键说明