          transmission OBJECT IDENTIFIER ::= { mib-2 10 }          snmp         OBJECT IDENTIFIER ::= { mib-2 11 }          -- the System group          -- Implementation of the System group is mandatory for all          -- systems.  If an agent is not configured to have a value          -- for any of these variables, a string of length 0 is          -- returned.          sysDescr OBJECT-TYPE              SYNTAX  DisplayString (SIZE (0..255))              ACCESS  read-only              STATUS  mandatorySNMP Working Group                                             [Page 13]RFC 1213                         MIB-II                       March 1991              DESCRIPTION                      "A textual description of the entity.  This value                      should include the full name and version                      identification of the system's hardware type,                      software operating-system, and networking                      software.  It is mandatory that this only contain                      printable ASCII characters."              ::= { system 1 }          sysObjectID OBJECT-TYPE              SYNTAX  OBJECT IDENTIFIER              ACCESS  read-only              STATUS  mandatory              DESCRIPTION                      "The vendor's authoritative identification of the                      network management subsystem contained in the                      entity.  This value is allocated within the SMI                      enterprises subtree (1.3.6.1.4.1) and provides an                      easy and unambiguous means for determining `what                      kind of box' is being managed.  For example, if                      vendor `Flintstones, Inc.' was assigned the                      subtree 1.3.6.1.4.1.4242, it could assign the                      identifier 1.3.6.1.4.1.4242.1.1 to its `Fred                      Router'."              ::= { system 2 }          sysUpTime OBJECT-TYPE              SYNTAX  TimeTicks              ACCESS  read-only              STATUS  mandatory              DESCRIPTION                      "The time (in hundredths of a second) since the                      network management portion of the system was last                      re-initialized."              ::= { system 3 }          sysContact OBJECT-TYPE              SYNTAX  DisplayString (SIZE (0..255))              ACCESS  read-write              STATUS  mandatory              DESCRIPTION                      "The textual identification of the contact person                      for this managed node, together with information                      on how to contact this person."              ::= { system 4 }          sysName OBJECT-TYPE              SYNTAX  DisplayString (SIZE (0..255))SNMP Working Group                                             [Page 14]RFC 1213                         MIB-II                       March 1991              ACCESS  read-write              STATUS  mandatory              DESCRIPTION                      "An administratively-assigned name for this                      managed node.  By convention, this is the node's                      fully-qualified domain name."              ::= { system 5 }          sysLocation OBJECT-TYPE              SYNTAX  DisplayString (SIZE (0..255))              ACCESS  read-write              STATUS  mandatory              DESCRIPTION                      "The physical location of this node (e.g.,                      `telephone closet, 3rd floor')."              ::= { system 6 }          sysServices OBJECT-TYPE              SYNTAX  INTEGER (0..127)              ACCESS  read-only              STATUS  mandatory              DESCRIPTION                      "A value which indicates the set of services that                      this entity primarily offers.                      The value is a sum.  This sum initially takes the                      value zero, Then, for each layer, L, in the range                      1 through 7, that this node performs transactions                      for, 2 raised to (L - 1) is added to the sum.  For                      example, a node which performs primarily routing                      functions would have a value of 4 (2^(3-1)).  In                      contrast, a node which is a host offering                      application services would have a value of 72                      (2^(4-1) + 2^(7-1)).  Note that in the context of                      the Internet suite of protocols, values should be                      calculated accordingly:                           layer  functionality                               1  physical (e.g., repeaters)                               2  datalink/subnetwork (e.g., bridges)                               3  internet (e.g., IP gateways)                               4  end-to-end  (e.g., IP hosts)                               7  applications (e.g., mail relays)                      For systems including OSI protocols, layers 5 and                      6 may also be counted."              ::= { system 7 }SNMP Working Group                                             [Page 15]RFC 1213                         MIB-II                       March 1991          -- the Interfaces group          -- Implementation of the Interfaces group is mandatory for          -- all systems.          ifNumber OBJECT-TYPE              SYNTAX  INTEGER              ACCESS  read-only              STATUS  mandatory              DESCRIPTION                      "The number of network interfaces (regardless of                      their current state) present on this system."              ::= { interfaces 1 }          -- the Interfaces table          -- The Interfaces table contains information on the entity's          -- interfaces.  Each interface is thought of as being          -- attached to a `subnetwork'.  Note that this term should          -- not be confused with `subnet' which refers to an          -- addressing partitioning scheme used in the Internet suite          -- of protocols.          ifTable OBJECT-TYPE              SYNTAX  SEQUENCE OF IfEntry              ACCESS  not-accessible              STATUS  mandatory              DESCRIPTION                      "A list of interface entries.  The number of                      entries is given by the value of ifNumber."              ::= { interfaces 2 }          ifEntry OBJECT-TYPE              SYNTAX  IfEntry              ACCESS  not-accessible              STATUS  mandatory              DESCRIPTION                      "An interface entry containing objects at the                      subnetwork layer and below for a particular                      interface."              INDEX   { ifIndex }              ::= { ifTable 1 }          IfEntry ::=              SEQUENCE {                  ifIndex                      INTEGER,SNMP Working Group                                             [Page 16]RFC 1213                         MIB-II                       March 1991                  ifDescr                      DisplayString,                  ifType                      INTEGER,                  ifMtu                      INTEGER,                  ifSpeed                      Gauge,                  ifPhysAddress                      PhysAddress,                  ifAdminStatus                      INTEGER,                  ifOperStatus                      INTEGER,                  ifLastChange                      TimeTicks,                  ifInOctets                      Counter,                  ifInUcastPkts                      Counter,                  ifInNUcastPkts                      Counter,                  ifInDiscards                      Counter,                  ifInErrors                      Counter,                  ifInUnknownProtos                      Counter,                  ifOutOctets                      Counter,                  ifOutUcastPkts                      Counter,                  ifOutNUcastPkts                      Counter,                  ifOutDiscards                      Counter,                  ifOutErrors                      Counter,                  ifOutQLen                      Gauge,                  ifSpecific                      OBJECT IDENTIFIER              }          ifIndex OBJECT-TYPE              SYNTAX  INTEGER              ACCESS  read-only              STATUS  mandatorySNMP Working Group                                             [Page 17]RFC 1213                         MIB-II                       March 1991              DESCRIPTION                      "A unique value for each interface.  Its value                      ranges between 1 and the value of ifNumber.  The                      value for each interface must remain constant at                      least from one re-initialization of the entity's                      network management system to the next re-                      initialization."              ::= { ifEntry 1 }          ifDescr OBJECT-TYPE              SYNTAX  DisplayString (SIZE (0..255))              ACCESS  read-only              STATUS  mandatory              DESCRIPTION                      "A textual string containing information about the                      interface.  This string should include the name of                      the manufacturer, the product name and the version                      of the hardware interface."              ::= { ifEntry 2 }          ifType OBJECT-TYPE              SYNTAX  INTEGER {                          other(1),          -- none of the following                          regular1822(2),                          hdh1822(3),                          ddn-x25(4),                          rfc877-x25(5),                          ethernet-csmacd(6),                          iso88023-csmacd(7),                          iso88024-tokenBus(8),                          iso88025-tokenRing(9),                          iso88026-man(10),                          starLan(11),                          proteon-10Mbit(12),                          proteon-80Mbit(13),                          hyperchannel(14),                          fddi(15),                          lapb(16),                          sdlc(17),                          ds1(18),           -- T-1                          e1(19),            -- european equiv. of T-1                          basicISDN(20),                          primaryISDN(21),   -- proprietary serial                          propPointToPointSerial(22),                          ppp(23),                          softwareLoopback(24),                          eon(25),            -- CLNP over IP [11]                          ethernet-3Mbit(26),SNMP Working Group                                             [Page 18]RFC 1213                         MIB-II                       March 1991                          nsip(27),           -- XNS over IP                          slip(28),           -- generic SLIP                          ultra(29),          -- ULTRA technologies                          ds3(30),            -- T-3                          sip(31),            -- SMDS                          frame-relay(32)                      }              ACCESS  read-only              STATUS  mandatory              DESCRIPTION                      "The type of interface, distinguished according to                      the physical/link protocol(s) immediately `below'                      the network layer in the protocol stack."              ::= { ifEntry 3 }          ifMtu OBJECT-TYPE              SYNTAX  INTEGER              ACCESS  read-only              STATUS  mandatory              DESCRIPTION                      "The size of the largest datagram which can be                      sent/received on the interface, specified in                      octets.  For interfaces that are used for                      transmitting network datagrams, this is the size                      of the largest network datagram that can be sent                      on the interface."              ::= { ifEntry 4 }          ifSpeed OBJECT-TYPE              SYNTAX  Gauge              ACCESS  read-only              STATUS  mandatory              DESCRIPTION                      "An estimate of the interface's current bandwidth                      in bits per second.  For interfaces which do not                      vary in bandwidth or for those where no accurate                      estimation can be made, this object should contain                      the nominal bandwidth."              ::= { ifEntry 5 }          ifPhysAddress OBJECT-TYPE              SYNTAX  PhysAddress              ACCESS  read-only              STATUS  mandatory              DESCRIPTION                      "The interface's address at the protocol layer                      immediately `below' the network layer in the                      protocol stack.  For interfaces which do not have

⌨️ 快捷键说明

复制代码 Ctrl + C
搜索代码 Ctrl + F
全屏模式 F11
切换主题 Ctrl + Shift + D
显示快捷键 ?
增大字号 Ctrl + =
减小字号 Ctrl + -