📄 rfc1213std0017.txt
字号:
transmission OBJECT IDENTIFIER ::= { mib-2 10 } snmp OBJECT IDENTIFIER ::= { mib-2 11 } -- the System group -- Implementation of the System group is mandatory for all -- systems. If an agent is not configured to have a value -- for any of these variables, a string of length 0 is -- returned. sysDescr OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) ACCESS read-only STATUS mandatorySNMP Working Group [Page 13]RFC 1213 MIB-II March 1991 DESCRIPTION "A textual description of the entity. This value should include the full name and version identification of the system's hardware type, software operating-system, and networking software. It is mandatory that this only contain printable ASCII characters." ::= { system 1 } sysObjectID OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "The vendor's authoritative identification of the network management subsystem contained in the entity. This value is allocated within the SMI enterprises subtree (1.3.6.1.4.1) and provides an easy and unambiguous means for determining `what kind of box' is being managed. For example, if vendor `Flintstones, Inc.' was assigned the subtree 1.3.6.1.4.1.4242, it could assign the identifier 1.3.6.1.4.1.4242.1.1 to its `Fred Router'." ::= { system 2 } sysUpTime OBJECT-TYPE SYNTAX TimeTicks ACCESS read-only STATUS mandatory DESCRIPTION "The time (in hundredths of a second) since the network management portion of the system was last re-initialized." ::= { system 3 } sysContact OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) ACCESS read-write STATUS mandatory DESCRIPTION "The textual identification of the contact person for this managed node, together with information on how to contact this person." ::= { system 4 } sysName OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255))SNMP Working Group [Page 14]RFC 1213 MIB-II March 1991 ACCESS read-write STATUS mandatory DESCRIPTION "An administratively-assigned name for this managed node. By convention, this is the node's fully-qualified domain name." ::= { system 5 } sysLocation OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) ACCESS read-write STATUS mandatory DESCRIPTION "The physical location of this node (e.g., `telephone closet, 3rd floor')." ::= { system 6 } sysServices OBJECT-TYPE SYNTAX INTEGER (0..127) ACCESS read-only STATUS mandatory DESCRIPTION "A value which indicates the set of services that this entity primarily offers. The value is a sum. This sum initially takes the value zero, Then, for each layer, L, in the range 1 through 7, that this node performs transactions for, 2 raised to (L - 1) is added to the sum. For example, a node which performs primarily routing functions would have a value of 4 (2^(3-1)). In contrast, a node which is a host offering application services would have a value of 72 (2^(4-1) + 2^(7-1)). Note that in the context of the Internet suite of protocols, values should be calculated accordingly: layer functionality 1 physical (e.g., repeaters) 2 datalink/subnetwork (e.g., bridges) 3 internet (e.g., IP gateways) 4 end-to-end (e.g., IP hosts) 7 applications (e.g., mail relays) For systems including OSI protocols, layers 5 and 6 may also be counted." ::= { system 7 }SNMP Working Group [Page 15]RFC 1213 MIB-II March 1991 -- the Interfaces group -- Implementation of the Interfaces group is mandatory for -- all systems. ifNumber OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The number of network interfaces (regardless of their current state) present on this system." ::= { interfaces 1 } -- the Interfaces table -- The Interfaces table contains information on the entity's -- interfaces. Each interface is thought of as being -- attached to a `subnetwork'. Note that this term should -- not be confused with `subnet' which refers to an -- addressing partitioning scheme used in the Internet suite -- of protocols. ifTable OBJECT-TYPE SYNTAX SEQUENCE OF IfEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A list of interface entries. The number of entries is given by the value of ifNumber." ::= { interfaces 2 } ifEntry OBJECT-TYPE SYNTAX IfEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An interface entry containing objects at the subnetwork layer and below for a particular interface." INDEX { ifIndex } ::= { ifTable 1 } IfEntry ::= SEQUENCE { ifIndex INTEGER,SNMP Working Group [Page 16]RFC 1213 MIB-II March 1991 ifDescr DisplayString, ifType INTEGER, ifMtu INTEGER, ifSpeed Gauge, ifPhysAddress PhysAddress, ifAdminStatus INTEGER, ifOperStatus INTEGER, ifLastChange TimeTicks, ifInOctets Counter, ifInUcastPkts Counter, ifInNUcastPkts Counter, ifInDiscards Counter, ifInErrors Counter, ifInUnknownProtos Counter, ifOutOctets Counter, ifOutUcastPkts Counter, ifOutNUcastPkts Counter, ifOutDiscards Counter, ifOutErrors Counter, ifOutQLen Gauge, ifSpecific OBJECT IDENTIFIER } ifIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatorySNMP Working Group [Page 17]RFC 1213 MIB-II March 1991 DESCRIPTION "A unique value for each interface. Its value ranges between 1 and the value of ifNumber. The value for each interface must remain constant at least from one re-initialization of the entity's network management system to the next re- initialization." ::= { ifEntry 1 } ifDescr OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) ACCESS read-only STATUS mandatory DESCRIPTION "A textual string containing information about the interface. This string should include the name of the manufacturer, the product name and the version of the hardware interface." ::= { ifEntry 2 } ifType OBJECT-TYPE SYNTAX INTEGER { other(1), -- none of the following regular1822(2), hdh1822(3), ddn-x25(4), rfc877-x25(5), ethernet-csmacd(6), iso88023-csmacd(7), iso88024-tokenBus(8), iso88025-tokenRing(9), iso88026-man(10), starLan(11), proteon-10Mbit(12), proteon-80Mbit(13), hyperchannel(14), fddi(15), lapb(16), sdlc(17), ds1(18), -- T-1 e1(19), -- european equiv. of T-1 basicISDN(20), primaryISDN(21), -- proprietary serial propPointToPointSerial(22), ppp(23), softwareLoopback(24), eon(25), -- CLNP over IP [11] ethernet-3Mbit(26),SNMP Working Group [Page 18]RFC 1213 MIB-II March 1991 nsip(27), -- XNS over IP slip(28), -- generic SLIP ultra(29), -- ULTRA technologies ds3(30), -- T-3 sip(31), -- SMDS frame-relay(32) } ACCESS read-only STATUS mandatory DESCRIPTION "The type of interface, distinguished according to the physical/link protocol(s) immediately `below' the network layer in the protocol stack." ::= { ifEntry 3 } ifMtu OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The size of the largest datagram which can be sent/received on the interface, specified in octets. For interfaces that are used for transmitting network datagrams, this is the size of the largest network datagram that can be sent on the interface." ::= { ifEntry 4 } ifSpeed OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS mandatory DESCRIPTION "An estimate of the interface's current bandwidth in bits per second. For interfaces which do not vary in bandwidth or for those where no accurate estimation can be made, this object should contain the nominal bandwidth." ::= { ifEntry 5 } ifPhysAddress OBJECT-TYPE SYNTAX PhysAddress ACCESS read-only STATUS mandatory DESCRIPTION "The interface's address at the protocol layer immediately `below' the network layer in the protocol stack. For interfaces which do not have
⌨️ 快捷键说明
复制代码
Ctrl + C
搜索代码
Ctrl + F
全屏模式
F11
切换主题
Ctrl + Shift + D
显示快捷键
?
增大字号
Ctrl + =
减小字号
Ctrl + -