📄 modbusmessage.java

📁 jamod is an object oriented implementation of the Modbus protocol, realized 100 in Java. It allows
💻 JAVA
字号:
//License/*** * Java Modbus Library (jamod) * Copyright (c) 2002-2004, jamod development team * All rights reserved. * * Redistribution and use in source and binary forms, with or without * modification, are permitted provided that the following conditions are * met: * * Redistributions of source code must retain the above copyright notice, * this list of conditions and the following disclaimer. * * Redistributions in binary form must reproduce the above copyright notice, * this list of conditions and the following disclaimer in the documentation * and/or other materials provided with the distribution. * * Neither the name of the author nor the names of its contributors * may be used to endorse or promote products derived from this software * without specific prior written permission. * * THIS SOFTWARE IS PROVIDED BY THE COPYRIGHT HOLDER AND CONTRIBUTORS ``AS * IS'' AND ANY EXPRESS OR IMPLIED WARRANTIES, INCLUDING, BUT NOT LIMITED TO, * THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR * PURPOSE ARE DISCLAIMED. IN NO EVENT SHALL THE REGENTS OR CONTRIBUTORS BE * LIABLE FOR ANY DIRECT, INDIRECT, INCIDENTAL, SPECIAL, EXEMPLARY, OR * CONSEQUENTIAL DAMAGES (INCLUDING, BUT NOT LIMITED TO, PROCUREMENT OF * SUBSTITUTE GOODS OR SERVICES; LOSS OF USE, DATA, OR PROFITS; OR BUSINESS * INTERRUPTION) HOWEVER CAUSED AND ON ANY THEORY OF LIABILITY, WHETHER IN * CONTRACT, STRICT LIABILITY, OR TORT (INCLUDING NEGLIGENCE OR OTHERWISE) * ARISING IN ANY WAY OUT OF THE USE OF THIS SOFTWARE, EVEN IF ADVISED OF THE * POSSIBILITY OF SUCH DAMAGE. ***/package net.wimpi.modbus.msg;//import java.io.EOFException;//import java.io.IOException;import net.wimpi.modbus.io.Transportable;/** * Interface defining a ModbusMessage. * * @author Dieter Wimberger * @version 1.2rc1 (09/11/2004) */public interface ModbusMessage    extends Transportable {  /**   * Sets the flag that marks this <tt>ModbusMessage</tt> as headless   * (for serial transport).   */  public void setHeadless();  /**   * Returns the transaction identifier of this   * <tt>ModbusMessage</tt> as <tt>int</tt>.<br>   * The identifier is a 2-byte (short) non negative   * integer value valid in the range of 0-65535.   * <p>   * @return the transaction identifier as <tt>int</tt>.   */  public int getTransactionID();  /**   * Returns the protocol identifier of this   * <tt>ModbusMessage</tt> as <tt>int</tt>.<br>   * The identifier is a 2-byte (short) non negative   * integer value valid in the range of 0-65535.   * <p>   * @return the protocol identifier as <tt>int</tt>.   */  public int getProtocolID();  /**   * Returns the length of the data appended   * after the protocol header.   * <p>   * @return the data length as <tt>int</tt>.   */  public int getDataLength();  /**   * Returns the unit identifier of  this   * <tt>ModbusMessage</tt> as <tt>int</tt>.<br>   * The identifier is a 1-byte non negative   * integer value valid in the range of 0-255.   * <p>   * @return the unit identifier as <tt>int</tt>.   */  public int getUnitID();  /**   * Returns the function code of this   * <tt>ModbusMessage</tt> as <tt>int</tt>.<br>   * The function code is a 1-byte non negative   * integer value valid in the range of 0-127.<br>   * Function codes are ordered in conformance   * classes their values are specified in   * <tt>net.wimpi.modbus.Modbus</tt>.   * <p>   * @return the function code as <tt>int</tt>.   *   * @see net.wimpi.modbus.Modbus   */  public int getFunctionCode();  /**   * Writes this <tt>ModbusMessage</tt> to the   * given raw <tt>OutputStream</tt>.   * <p>   * @param out the <tt>OutputStream</tt> to write to.   *   * @throws Exception if it fails to write to   *         the given <tt>OutputStream</tt>.   * @throws Exception if the stream ended   *         before all data has been written to it.   *   public void writeTo(OutputStream out) throws EOFException, IOException;   */  /**   * Returns the <i>raw</i> message as an array of   * bytes.   * <p>   * @return the <i>raw</i> message as <tt>byte[]</tt>.   *   public byte[] getMessage();   */  /**   * Returns the <i>raw</i> message as <tt>String</tt>   * containing a hexadecimal series of bytes.   * <br>   * This method is specially for debugging purposes,   * allowing to log the communication in a manner used   * in the specification document.   * <p>   * @return the <i>raw</i> message as <tt>String</tt>   *         containing a hexadecimal series of bytes.   *   */  public String getHexMessage();  /**   * Returns the total length this <tt>ModbusMessage</tt>.   * <p>   * @return the length as <tt>int</tt>.   *   public int length();   */}//interface ModbusMessage

⌨️ 快捷键说明

复制代码 Ctrl + C
搜索代码 Ctrl + F
全屏模式 F11
切换主题 Ctrl + Shift + D
显示快捷键 ?
增大字号 Ctrl + =
减小字号 Ctrl + -