⭐ 欢迎来到虫虫下载站! | 📦 资源下载 📁 资源专辑 ℹ️ 关于我们
⭐ 虫虫下载站

📄 rfc1516.txt

📁 中、英文RFC文档大全打包下载完全版 .
💻 TXT
📖 第 1 页 / 共 5 页
字号:
               rptrMonitorPortTotalErrors counters for all of the               ports in the group."       ::= { rptrMonitorGroupEntry 4 }   --   -- The Port Monitor TableMcMaster & McCloghrie                                          [Page 25]RFC 1516                   802.3 Repeater MIB             September 1993   --   rptrMonitorPortTable OBJECT-TYPE       SYNTAX    SEQUENCE OF RptrMonitorPortEntry       ACCESS    not-accessible       STATUS    mandatory       DESCRIPTION               "Table of performance and error statistics for the               ports."       ::= { rptrMonitorPortInfo 1 }   rptrMonitorPortEntry OBJECT-TYPE       SYNTAX    RptrMonitorPortEntry       ACCESS    not-accessible       STATUS    mandatory       DESCRIPTION               "An entry in the table, containing performance and               error statistics for a single port."       INDEX    { rptrMonitorPortGroupIndex, rptrMonitorPortIndex }       ::= { rptrMonitorPortTable 1 }   RptrMonitorPortEntry ::=       SEQUENCE {           rptrMonitorPortGroupIndex               INTEGER,           rptrMonitorPortIndex               INTEGER,           rptrMonitorPortReadableFrames               Counter,           rptrMonitorPortReadableOctets               Counter,           rptrMonitorPortFCSErrors               Counter,           rptrMonitorPortAlignmentErrors               Counter,           rptrMonitorPortFrameTooLongs               Counter,           rptrMonitorPortShortEvents               Counter,           rptrMonitorPortRunts               Counter,           rptrMonitorPortCollisions               Counter,           rptrMonitorPortLateEvents               Counter,           rptrMonitorPortVeryLongEvents               Counter,           rptrMonitorPortDataRateMismatchesMcMaster & McCloghrie                                          [Page 26]RFC 1516                   802.3 Repeater MIB             September 1993               Counter,           rptrMonitorPortAutoPartitions               Counter,           rptrMonitorPortTotalErrors               Counter       }   rptrMonitorPortGroupIndex OBJECT-TYPE       SYNTAX    INTEGER (1..1024)       ACCESS    read-only       STATUS    mandatory       DESCRIPTION               "This object identifies the group containing the               port for which this entry contains information."       ::= { rptrMonitorPortEntry 1 }   rptrMonitorPortIndex OBJECT-TYPE       SYNTAX    INTEGER (1..1024)       ACCESS    read-only       STATUS    mandatory       DESCRIPTION               "This object identifies the port within the group               for which this entry contains information."       REFERENCE               "Reference IEEE 802.3 Rptr Mgt, 19.2.6.2,               aPortID."       ::= { rptrMonitorPortEntry 2 }   rptrMonitorPortReadableFrames OBJECT-TYPE       SYNTAX    Counter       ACCESS    read-only       STATUS    mandatory       DESCRIPTION               "This object is the number of frames of valid               frame length that have been received on this port.               This counter is incremented by one for each frame               received on this port whose OctetCount is greater               than or equal to minFrameSize and less than or               equal to maxFrameSize (Ref: IEEE 802.3 Std,               4.4.2.1) and for which the FCSError and               CollisionEvent signals are not asserted.               This statistic provides one of the parameters               necessary for obtaining the packet error rate.               The approximate minimum time for rollover of this               counter is 80 hours."       REFERENCE               "Reference IEEE 802.3 Rptr Mgt, 19.2.6.2,McMaster & McCloghrie                                          [Page 27]RFC 1516                   802.3 Repeater MIB             September 1993               aReadableFrames."       ::= { rptrMonitorPortEntry 3 }   rptrMonitorPortReadableOctets OBJECT-TYPE       SYNTAX    Counter       ACCESS    read-only       STATUS    mandatory       DESCRIPTION               "This object is the number of octets contained in               valid frames that have been received on this port.               This counter is incremented by OctetCount for each               frame received on this port which has been               determined to be a readable frame (i.e., including               FCS octets but excluding framing bits and dribble               bits).               This statistic provides an indicator of the total               data transferred.  The approximate minimum time               for rollover of this counter is 58 minutes."       REFERENCE               "Reference IEEE 802.3 Rptr Mgt, 19.2.6.2,               aReadableOctets."       ::= { rptrMonitorPortEntry 4 }   rptrMonitorPortFCSErrors OBJECT-TYPE       SYNTAX    Counter       ACCESS    read-only       STATUS    mandatory       DESCRIPTION               "This counter is incremented by one for each frame               received on this port with the FCSError signal               asserted and the FramingError and CollisionEvent               signals deasserted and whose OctetCount is greater               than or equal to minFrameSize and less than or               equal to maxFrameSize (Ref: 4.4.2.1, IEEE 802.3               Std).               The approximate minimum time for rollover of this               counter is 80 hours."       REFERENCE               "Reference IEEE 802.3 Rptr Mgt, 19.2.6.2,               aFrameCheckSequenceErrors."       ::= { rptrMonitorPortEntry 5 }   rptrMonitorPortAlignmentErrors OBJECT-TYPE       SYNTAX    Counter       ACCESS    read-only       STATUS    mandatoryMcMaster & McCloghrie                                          [Page 28]RFC 1516                   802.3 Repeater MIB             September 1993       DESCRIPTION               "This counter is incremented by one for each frame               received on this port with the FCSError and               FramingError signals asserted and CollisionEvent               signal deasserted and whose OctetCount is greater               than or equal to minFrameSize and less than or               equal to maxFrameSize (Ref: IEEE 802.3 Std,               4.4.2.1).  If rptrMonitorPortAlignmentErrors is               incremented then the rptrMonitorPortFCSErrors               Counter shall not be incremented for the same               frame.               The approximate minimum time for rollover of this               counter is 80 hours."       REFERENCE               "Reference IEEE 802.3 Rptr Mgt, 19.2.6.2,               aAlignmentErrors."       ::= { rptrMonitorPortEntry 6 }   rptrMonitorPortFrameTooLongs OBJECT-TYPE       SYNTAX    Counter       ACCESS    read-only       STATUS    mandatory       DESCRIPTION               "This counter is incremented by one for each frame               received on this port whose OctetCount is greater               than maxFrameSize (Ref: 4.4.2.1, IEEE 802.3 Std).               If rptrMonitorPortFrameTooLongs is incremented               then neither the rptrMonitorPortAlignmentErrors               nor the rptrMonitorPortFCSErrors counter shall be               incremented for the frame.               The approximate minimum time for rollover of this               counter is 61 days."       REFERENCE               "Reference IEEE 802.3 Rptr Mgt, 19.2.6.2,               aFramesTooLong."       ::= { rptrMonitorPortEntry 7 }   rptrMonitorPortShortEvents OBJECT-TYPE       SYNTAX    Counter       ACCESS    read-only       STATUS    mandatory       DESCRIPTION               "This counter is incremented by one for each               CarrierEvent on this port with ActivityDuration               less than ShortEventMaxTime.  ShortEventMaxTime is               greater than 74 bit times and less than 82 bitMcMaster & McCloghrie                                          [Page 29]RFC 1516                   802.3 Repeater MIB             September 1993               times.  ShortEventMaxTime has tolerances included               to provide for circuit losses between a               conformance test point at the AUI and the               measurement point within the state machine.               Note:  shortEvents may indicate externally               generated noise hits which will cause the repeater               to transmit Runts to its other ports, or propagate               a collision (which may be late) back to the               transmitting DTE and damaged frames to the rest of               the network.               Implementors may wish to consider selecting the               ShortEventMaxTime towards the lower end of the               allowed tolerance range to accommodate bit losses               suffered through physical channel devices not               budgeted for within this standard.               The approximate minimum time for rollover of this               counter is 16 hours."       REFERENCE               "Reference IEEE 802.3 Rptr Mgt, 19.2.6.2,               aShortEvents."       ::= { rptrMonitorPortEntry 8 }   rptrMonitorPortRunts OBJECT-TYPE       SYNTAX    Counter       ACCESS    read-only       STATUS    mandatory       DESCRIPTION               "This counter is incremented by one for each               CarrierEvent on this port that meets one of the               following two conditions.  Only one test need be               made.  a) The ActivityDuration is greater than               ShortEventMaxTime and less than ValidPacketMinTime               and the CollisionEvent signal is deasserted.  b)               The OctetCount is less than 64, the               ActivityDuration is greater than ShortEventMaxTime               and the CollisionEvent signal is deasserted.               ValidPacketMinTime is greater than or equal to 552               bit times and less than 565 bit times.               An event whose length is greater than 74 bit times               but less than 82 bit times shall increment either               the shortEvents counter or the runts counter but               not both.  A CarrierEvent greater than or equal to               552 bit times but less than 565 bit times may or               may not be counted as a runt.McMaster & McCloghrie                                          [Page 30]RFC 1516                   802.3 Repeater MIB             September 1993               ValidPacketMinTime has tolerances included to               provide for circuit losses between a conformance               test point at the AUI and the measurement point               within the state machine.               Runts usually indicate collision fragments, a               normal network event.  In certain situations               associated with large diameter networks a               percentage of collision fragments may exceed               ValidPacketMinTime.               The approximate minimum time for rollover of this               counter is 16 hours."       REFERENCE               "Reference IEEE 802.3 Rptr Mgt, 19.2.6.2, aRunts."       ::= { rptrMonitorPortEntry 9 }   rptrMonitorPortCollisions OBJECT-TYPE       SYNTAX    Counter       ACCESS    read-only       STATUS    mandatory       DESCRIPTION               "This counter is incremented by one for any               CarrierEvent signal on any port for which the               CollisionEvent signal on this port is also               asserted.               The approximate minimum time for rollover of this               counter is 16 hours."       REFERENCE               "Reference IEEE 802.3 Rptr Mgt, 19.2.6.2,               aCollisions."       ::= { rptrMonitorPortEntry 10 }   rptrMonitorPortLateEvents OBJECT-TYPE       SYNTAX    Counter       ACCESS    read-only       STATUS    mandatory       DESCRIPTION               "This counter is incremented by one for each               CarrierEvent on this port in which the CollIn(X)               variable transitions to the value SQE (Ref:               9.6.6.2, IEEE 802.3 Std) while the               ActivityDuration is greater than the               LateEventThreshold.  Such a CarrierEvent is               counted twice, as both a collision and as a               lateEvent.McMaster & McCloghrie                                          [Page 31]RFC 1516                   802.3 Repeater MIB             September

⌨️ 快捷键说明

复制代码 Ctrl + C
搜索代码 Ctrl + F
全屏模式 F11
切换主题 Ctrl + Shift + D
显示快捷键 ?
增大字号 Ctrl + =
减小字号 Ctrl + -