rfc2643.txt

来自「中、英文RFC文档大全打包下载完全版 .」· 文本 代码 · 共 1,692 行 · 第 1/5 页

TXT
1,692
字号
   -  Eight call processing service centers that provide the essential      services required to process call connections.  The call      processing service centers are described in Section 4.   -  A Call Tap module that supports the monitoring of call      connections.  The Call Tap module is described in Section 5.   -  The InterSwitch Message Protocol (ISMP) that provides a consistent      method of encapsulating and transmitting control messages      exchanged between SFVLAN switches.  (Note that ISMP is not a      discrete software module.  Instead, its functionality is      distributed among those service centers and software modules that      need to communicate with other switches in the fabric.) The      Interswitch Message Protocol and the formats of the individual      interswitch messages are described in Section 6.3. Base Services   The SFVLAN base services act as the interface between the switch   hardware and the SFVLAN service centers running on the switch CPU.   This relationship is shown in Figure 2.  This figure is a replication   of the bottom portion of Figure 1.            |    Directory       Resolve                   |            |        ^              ^                      |            |        |              |                      |            |        |    +---------^-----------+          |            |        +----<    Base Services    |          |            |             +-----^---------------+          |            +-------------------|--------------------------+             Switch CPU         |                                | Host control port                          +-----O----------------+                          |     ^ no cnx         |                Layer 2   |     |                |               ---------->O-----+--------------->O----------->                SA/DA pr  |          known cnx   |                          +----------------------+                           Switch hardware                        Figure 2:  Base ServicesRuffen, et al.               Informational                     [Page 13]RFC 2643     Cabletron's SecureFast VLAN Operational Model   August 1999   During normal operation of the switch, data packets arriving at   any one of the local switch ports are examined in the switch   hardware.  If the packet's source and destination address (SA/DA)   pair match a known connection, the hardware simply forwards the   packet out the outport specified by the connection.   If the SA/DA pair do not match any known connection, the hardware   diverts the packet to the host control port where it is picked up   by the SFVLAN base services.  The base services generate a   structure known as a state box that tracks the progress of the   call connection request as the request moves through the call   processing service centers.   After creating the call's state box, the base services check to   determine if the call is a duplicate of a call already being   processed.  If not, a request is issued to the Directory Service   Center (Section 4.1) to add the call's source address to the local   Node and Alias Tables.  The base services then hand the call off to   the Resolve Service Center (Section 4.3) for further processing.4. Call Processing   Call connection processing is handled by a set of eight service   centers, each with one or more servers.  The servers within a   service center are called in a particular sequence.  Each server   records the results of its processing in the call connection   request state box and passes the state box to the next server in   the sequence.   In the sections that follow, servers are listed in the order in   which they are called.4.1 Directory Service Center   The Directory Service Center is responsible for cataloging the MAC   addresses and alias information for both local and remote   endstations.  The information is stored in two tables -- the Node   Table and the Alias Table.   -  The Node Table contains the MAC addresses of endstations      attached to the local switch.  It also contains a cache of      remote endstations detected by the Resolve Service Center      (Section 4.3).   Every entry in the Node Table has one or more      corresponding entries in the Alias Table.Ruffen, et al.               Informational                     [Page 14]RFC 2643     Cabletron's SecureFast VLAN Operational Model   August 1999   -  The Alias Table contains protocol alias information for each      endstation.  An endstation alias can be a network address (such      as an IP or IPX address), a VLAN identifier, or any other      protocol identifier.  Since every endstation is a member of at      least one VLAN (the default VLAN for the port), there is always      at least one entry in the Alias Table for each entry in the      Node Table.      Note:         The Node and Alias Tables must remain synchronized.         That is, when an endstation's final alias is removed         from the Alias Table, the endstation entry is removed         from the Node Table.   Note that the total collection of all Node Tables and Alias Tables   across all switches is known as the "virtual" directory of the   switch fabric.  The virtual directory contains address mappings of   all known endstations in the fabric.4.1.1 Local Add Server   The Directory Local Add server adds entries to the local Node or   Alias Tables.  It is called by the base services (Section 3) to   add a local endstation and by the Interswitch Resolve (Section   4.3.4) server to add an endstation discovered on a remote switch.4.1.2 Inverse Resolve Server   The Directory Inverse Resolve server is invoked when a new   endstation has been discovered on the local switch (that is, when   the Local Add server was successful in adding the endstation).   The server provides two functions:   -  It populates the Node and Alias Tables with local entries      during switch initialization.   -  It processes a new endstation discovered after the fabric      topology has converged to a stable state.   In both instances, the processing is identical.Ruffen, et al.               Informational                     [Page 15]RFC 2643     Cabletron's SecureFast VLAN Operational Model   August 1999   When a new endstation is detected on one of the switch's local   ports, the Inverse Resolve server sends an Interswitch New User   request message (Section 6.5) over the switch flood path to all   other switches in the fabric.  The purpose of the Interswitch New   User request is two-fold:   -  It informs the other switches of the new endstation address.      Any entries for that endstation in the local databases of other      switches should be dealt with appropriately.   -  It requests information about any static VLAN(s) to which the      endstation has been assigned.   When a switch receives an Interswitch New User request message   from one of its upstream neighbors, it first forwards the message   to all its downstream neighbors.  No actual processing or VLAN   resolution is attempted until the message reaches the end of the   switch flood path and begins its trip back along the return path.   This ensures that all switches in the fabric receive notification   of the new user and have synchronized their databases.   If a switch receives an Interswitch New User request message but   has no downstream neighbors, it does the following:   -  If the endstation was previously connected to one of the      switch's local ports, the switch formulates an Interswitch New      User Response message by loading the VLAN identifier(s) of the      static VLAN(s) to which the endstation was assigned, along with      its own MAC address.  (VLAN identifiers are stored in      Tag/Length/Value (TLV) format.  See Section 2.3.)  The switch      then sets the message status field to NewUserAck, and returns      the message to its upstream (requesting) neighbor.      Otherwise, the switch sets the status field to NewUserUnknown      and returns the message to its upstream neighbor.   -  The switch then deletes the endstation from its local database,      as well as any entries associated with the endstation in its      connection table.   When a switch forwards an Interswitch New User request message to   its downstream neighbors, it keeps track of the number of requests   it has sent out and does not respond back to its upstream neighbor   until all requests have been responded to.Ruffen, et al.               Informational                     [Page 16]RFC 2643     Cabletron's SecureFast VLAN Operational Model   August 1999   -  As each response is received, the switch checks the status      field of the message.  If the status is NewUserAck, the switch      retains the information in that response.  When all requests      have been responded to, the switch returns the NewUserAck      response to its upstream neighbor.   -  If all the Interswitch New User Request messages have been      responded to with a status of NewUserUnknown, the switch checks      to see if the endstation was previously connected to one of its      local ports.  If so, the switch formulates an Interswitch New      User Response message by loading the VLAN identifier(s) of the      static VLAN(s) to which the endstation was assigned, along with      its own MAC address.  The switch then sets the message status      field to NewUserAck, and returns the message to its upstream      (requesting) neighbor.      Otherwise, the switch sets the status field to NewUserUnknown      and returns the message to its upstream neighbor.   -  The switch then deletes the endstation from its local database,      as well as any entries associated with the endstation in its      connection table.   When the originating switch has received responses to all the   Interswitch New User Request messages it has sent, it does the   following:   -  If it has received a response message with a status of      NewUserAck, it loads the new VLAN information into its local      database.   -  If all responses have been received with a status of      NewUserUnknown, the originating switch assumes that the      endstation was not previously connected anywhere in the network      and assigns it to a VLAN according to the VLAN membership rules      and order of precedence.   If any Interswitch New User Request message has not been responded   to within a certain predetermined time (currently 5 seconds), the   originating switch recalculates the switch flood path and resends   the Interswitch New User Request message.Ruffen, et al.               Informational                     [Page 17]RFC 2643     Cabletron's SecureFast VLAN Operational Model   August 19994.1.3 Local Delete Server   The Directory Local Delete server removes entries (both local and   remote) from the local Node and Alias Tables.  It is invoked when   an endstation, previously known to be attached to one switch, has   been moved and discovered on another switch.   Note also that remote entries are cached and are purged from the   tables on a first-in/first-out basis as space is needed in the   cache.4.2 Topology Service Center   The Topology Service Center is responsible for maintaining three   databases relating to the topology of the switch fabric:   -  The topology table of SFVLAN switches that are physical      neighbors to the local switch.   -  The spanning tree that defines the loop-free switch flood path      used for transmitting undirected interswitch messages.   -  The directed graph that is used to calculate the best path(s)      for call connections.4.2.1 Neighbor Discovery Server   The Topology Neighbor Discovery server uses Interswitch Keepalive   messages to detect the switch's neighbors and establish the   topology of the switching fabric.  Interswitch Keepalive messages   are exchanged in accordance with Cabletron's VlanHello protocol,   described in detail in [IDhello].4.2.2 Spanning Tree Server   The Topology Spanning Tree server is invoked by the Topology   Neighbor Discovery server when a neighboring SFVLAN switch is   either discovered or lost -- that is, when the operational status   of a network link changes.   The Spanning Tree server exchanges interswitch messages with   neighboring SFVLAN switches to calculate the switch flood path   over which undirected interswitch messages are sent.  There are   two parts to this process:   -  Creating and maintaining the spanning tree   -  Remote blockingRuffen, et al.               Informational                     [Page 18]RFC 2643     Cabletron's SecureFast VLAN Operational Model   August 19994.2.2.1 Creating and Maintaining the Spanning Tree   In a network with redundant network links, a packet traveling between

⌨️ 快捷键说明

复制代码Ctrl + C
搜索代码Ctrl + F
全屏模式F11
增大字号Ctrl + =
减小字号Ctrl + -
显示快捷键?