rfc2955.txt

来自「中、英文RFC文档大全打包下载完全版 .」· 文本 代码 · 共 1,618 行 · 第 1/5 页

TXT
1,618 行
字号
                  Email:      Andy.Malis@vivacenetworks.com                  WG editor:  Kenneth Rehbehn                              Megisto Systems, Inc.                  Email:      krehbehn@megisto.com                  Co-author:  Orly Nicklass                              RAD Data Communications Ltd.                  EMail:      orly_n@rad.co.il                  Co-author:  George Mouradian                              AT&T Labs                  EMail:      gvm@att.com"             DESCRIPTION                     "The MIB module for monitoring and controlling the                     Frame Relay/ATM PVC Service Interworking                     Function."             --             -- Revision History             --Rehbehn, et al.             Standards Track                    [Page 12]RFC 2955           FR to ATM Service Interworking MIB       October 2000             REVISION "200009280000Z"             DESCRIPTION                  "Published as RFC 2955"         ::= { mib-2 86 }         --         -- Object Identifiers         --            frAtmIwfMIBObjects      OBJECT IDENTIFIER                                         ::= { frAtmIwfMIB 1 }            frAtmIwfTraps           OBJECT IDENTIFIER                                         ::= { frAtmIwfMIB 2 }            frAtmIwfTrapsPrefix     OBJECT IDENTIFIER                                         ::= { frAtmIwfTraps 0 }            frAtmIwfConformance     OBJECT IDENTIFIER                                         ::= { frAtmIwfMIB 3 }            frAtmIwfGroups          OBJECT IDENTIFIER                                         ::= { frAtmIwfConformance 1 }            frAtmIwfCompliances     OBJECT IDENTIFIER                                         ::= { frAtmIwfConformance 2 }         --         --  The FR/ATM PVC Service IWF Group         --         --      The Frame Relay/ATM PVC Service Interworking Function         --      Connection Table contains all connections utilizing         --      the interworking function.         --         frAtmIwfConnIndexNext OBJECT-TYPE              SYNTAX         Integer32 (0..2147483647)              MAX-ACCESS     read-only              STATUS         current              DESCRIPTION                     "This object contains an appropriate value to be                     used for frAtmIwfConnIndex  when creating entries                     in the frAtmIwfConnectionTable. The value 0                     indicates that no unassigned entries are                     available. To obtain the frAtmIwfConnIndexNext                     value for a new entry, the manager issues a                     management protocol retrieval operation to obtain                     the current value of this object.  After each                     retrieval, the agent should modify the value to                     the next unassigned index."              ::= { frAtmIwfMIBObjects 1 }Rehbehn, et al.             Standards Track                    [Page 13]RFC 2955           FR to ATM Service Interworking MIB       October 2000         frAtmIwfConnectionTable OBJECT-TYPE             SYNTAX      SEQUENCE OF FrAtmIwfConnectionEntry             MAX-ACCESS  not-accessible             STATUS      current             DESCRIPTION                     "A table in which each row represents a Frame                     Relay/ATM interworking connection."             ::= { frAtmIwfMIBObjects 2 }         frAtmIwfConnectionEntry OBJECT-TYPE             SYNTAX      FrAtmIwfConnectionEntry             MAX-ACCESS  not-accessible             STATUS      current             DESCRIPTION                     "The FrAtmIwfConnectionEntry provides an entry for                     an interworking connection between a frame relay                     PVC and one or more ATM PVCs, or an ATM PVC and                     one or more frame relay PVCs.  A single frame                     relay PVC connected to a single ATM PVC is                     referred to as a `point-to-point' connection and                     is represented by a single row in the FR/ATM IWF                     Connection Table.  The case of a single frame                     relay PVC connected to multiple ATM PVCs (or                     single ATM PVC connected to multiple frame relay                     PVCs) is referred to as a `point-to-multipoint'                     connection and is represented by multiple rows in                     the FR/ATM IWF Connection Table.                     The object frAtmIwfConnIndex uniquely identifies                     each point-to-point or point-to-multipoint                     connection.  The manager obtains the                     frAtmIwfConnIndex value by reading the                     frAtmIwfConnIndexNext object.                     After a frAtmIwfConnIndex is assigned for the                     connection, the manager creates one or more rows                     in the Cross Connect Table; one for each cross-                     connection between the frame relay PVC and an ATM                     PVC. In the case of `point-to-multipoint'                     connections, all rows are indexed by the same                     frAtmIwfConnIndex value and MUST refer to the same                     frame relay PVC or ATM PVC respectively.  An entry                     can be created only when at least one pair of                     frame relay and ATM PVCs exist.                     A row can be established by one-step set-request                     with all required parameter values and                     frAtmIwfConnRowStatus set to createAndGo(4). TheRehbehn, et al.             Standards Track                    [Page 14]RFC 2955           FR to ATM Service Interworking MIB       October 2000                     Agent should perform all error checking as needed.                     A pair of cross-connected PVCs, as identified by a                     particular value of the indexes, is released by                     setting frAtmIwfConnRowStatus to destroy(6). The                     Agent may release all associated resources. The                     manager may remove the related PVCs thereafter.                     Indexes are persistent across reboots of the                     system."             INDEX   { frAtmIwfConnIndex,                       frAtmIwfConnAtmPort,                       frAtmIwfConnVpi,                       frAtmIwfConnVci,                       frAtmIwfConnFrPort,                       frAtmIwfConnDlci                     }             ::= { frAtmIwfConnectionTable 1 }         FrAtmIwfConnectionEntry ::=             SEQUENCE {                 frAtmIwfConnIndex                      Integer32,                 frAtmIwfConnAtmPort                    InterfaceIndex,                 frAtmIwfConnVpi                        AtmVpIdentifier,                 frAtmIwfConnVci                        AtmVcIdentifier,                 frAtmIwfConnFrPort                     InterfaceIndex,                 frAtmIwfConnDlci                       Integer32,                 frAtmIwfConnRowStatus                  RowStatus,                 frAtmIwfConnAdminStatus                INTEGER,                 frAtmIwfConnAtm2FrOperStatus           INTEGER,                 frAtmIwfConnAtm2FrLastChange           TimeStamp,                 frAtmIwfConnFr2AtmOperStatus           INTEGER,                 frAtmIwfConnFr2AtmLastChange           TimeStamp,                 frAtmIwfConnectionDescriptor           Integer32,                 frAtmIwfConnFailedFrameTranslate       Counter32,                 frAtmIwfConnOverSizedFrames            Counter32,                 frAtmIwfConnFailedAal5PduTranslate     Counter32,                 frAtmIwfConnOverSizedSDUs              Counter32,                 frAtmIwfConnCrcErrors                  Counter32,                 frAtmIwfConnSarTimeOuts                Counter32         }         frAtmIwfConnIndex  OBJECT-TYPE             SYNTAX      Integer32  (1..2147483647)             MAX-ACCESS  not-accessible             STATUS      current             DESCRIPTION                     "A unique value for each point-to-point or point-                     to-multipoint connection.  The manager obtains the                     frAtmIwfConnIndex value by reading theRehbehn, et al.             Standards Track                    [Page 15]RFC 2955           FR to ATM Service Interworking MIB       October 2000                     frAtmIwfConnIndexNext object.  A point-to-                     multipoint connection will be represented in the                     frAtmIwfConnectionTable with multiple entries that                     share the same frAtmIwfConnIndex value."             ::= { frAtmIwfConnectionEntry 1 }         frAtmIwfConnAtmPort OBJECT-TYPE             SYNTAX      InterfaceIndex             MAX-ACCESS  not-accessible             STATUS      current             DESCRIPTION                     "The index in the ifTable that identifies the ATM                     port for this interworking connection."             ::= { frAtmIwfConnectionEntry 2 }         frAtmIwfConnVpi OBJECT-TYPE             SYNTAX      AtmVpIdentifier             MAX-ACCESS  not-accessible             STATUS      current             DESCRIPTION                     "The VPI of the ATM PVC end point for this                      interworking connection."             ::= { frAtmIwfConnectionEntry 3 }         frAtmIwfConnVci OBJECT-TYPE             SYNTAX      AtmVcIdentifier             MAX-ACCESS  not-accessible             STATUS      current             DESCRIPTION                     "The VCI of the ATM PVC end point for this                     interworking                      connection."             ::= { frAtmIwfConnectionEntry 4 }         frAtmIwfConnFrPort OBJECT-TYPE             SYNTAX      InterfaceIndex             MAX-ACCESS  not-accessible             STATUS      current             DESCRIPTION                     "The index in the ifTable that identifies the                     frame relay port for this interworking                     connection."             ::= { frAtmIwfConnectionEntry 5 }         frAtmIwfConnDlci OBJECT-TYPE             SYNTAX      Integer32 (16..4194303)             MAX-ACCESS  not-accessible             STATUS      currentRehbehn, et al.             Standards Track                    [Page 16]RFC 2955           FR to ATM Service Interworking MIB       October 2000             DESCRIPTION                     "The DLCI that identifies the frame relay PVC end                     point for this interworking connection."             ::= { frAtmIwfConnectionEntry 6 }         frAtmIwfConnRowStatus OBJECT-TYPE             SYNTAX      RowStatus             MAX-ACCESS  read-create             STATUS      current             DESCRIPTION                     "The table row may be created with                     'createAndWait(5)' or 'createAndGo(4)'.                     To activate a connection entry, a valid connection                     descriptor MUST be established in the                     frAtmIwfConnectionDescriptor object.                     This object is set to 'destroy(6)' to delete the                     table row.  Before the table row is destroyed, the                     OperStatus/AdminStatus of the corresponding                     endpoints MUST be 'down(2)'.  The deactivation of                     the ATM endpoint MAY occur as a side-effect of                     deleting the FR/ATM IWF cross-connection table                     row.  Otherwise, 'destroy(6)' operation MUST fail                     (error code 'inconsistentValue')."             ::= { frAtmIwfConnectionEntry 7 }         frAtmIwfConnAdminStatus OBJECT-TYPE             SYNTAX      INTEGER { up(1), down(2) }             MAX-ACCESS  read-create             STATUS      current             DESCRIPTION                     "The desired operational state for this FR/ATM                     interworked connection.                     up(1)       = Activate the connection. Before the                                   activation can be completed, the                                   OperStatus/AdminStatus of the                                   corresponding endpoints MUST be                                   'up(1)'.  The activation of the                                   corresponding endpoints MAY occur as                                   a side-effect of activating the                                   FR/ATM IWF cross-connection.                     down(2)     = Deactivate the connection. Before                                   the deactivation can be completed,                                   the atmVclAdminStatus of the                                   corresponding ATM endpoint MUST be                                   'down(2)'.  The deactivation of theRehbehn, et al.             Standards Track                    [Page 17]RFC 2955           FR to ATM Service Interworking MIB       October 2000                                   ATM endpoint MAY occur as a                                   side-effect of deactivating the                                   FR/ATM IWF cross-connection."             ::= { frAtmIwfConnectionEntry 8 }         frAtmIwfConnAtm2FrOperStatus     OBJECT-TYPE             SYNTAX      INTEGER { up(1), down(2) }             MAX-ACCESS  read-only             STATUS      current             DESCRIPTION                     "The current operational state of this                     interworking connection in the ATM to frame                     relay direction."             ::= { frAtmIwfConnectionEntry 9 }

⌨️ 快捷键说明

复制代码Ctrl + C
搜索代码Ctrl + F
全屏模式F11
增大字号Ctrl + =
减小字号Ctrl + -
显示快捷键?