📄 rfc1628.txt
字号:
RFC 1628 UPS MIB May 1994 STATUS current DESCRIPTION "A list of input table entries. The number of entries is given by the value of upsInputNumLines." ::= { upsInput 3 } upsInputEntry OBJECT-TYPE SYNTAX UpsInputEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry containing information applicable to a particular input line." INDEX { upsInputLineIndex } ::= { upsInputTable 1 } UpsInputEntry ::= SEQUENCE { upsInputLineIndex PositiveInteger, upsInputFrequency NonNegativeInteger, upsInputVoltage NonNegativeInteger, upsInputCurrent NonNegativeInteger, upsInputTruePower NonNegativeInteger } upsInputLineIndex OBJECT-TYPE SYNTAX PositiveInteger MAX-ACCESS not-accessible STATUS current DESCRIPTION "The input line identifier." ::= { upsInputEntry 1 } upsInputFrequency OBJECT-TYPE SYNTAX NonNegativeInteger UNITS "0.1 Hertz" MAX-ACCESS read-only STATUS current DESCRIPTION "The present input frequency." ::= { upsInputEntry 2 } upsInputVoltage OBJECT-TYPE SYNTAX NonNegativeInteger UNITS "RMS Volts" MAX-ACCESS read-only STATUS current DESCRIPTION "The magnitude of the present input voltage."Case [Page 8]RFC 1628 UPS MIB May 1994 ::= { upsInputEntry 3 } upsInputCurrent OBJECT-TYPE SYNTAX NonNegativeInteger UNITS "0.1 RMS Amp" MAX-ACCESS read-only STATUS current DESCRIPTION "The magnitude of the present input current." ::= { upsInputEntry 4 } upsInputTruePower OBJECT-TYPE SYNTAX NonNegativeInteger UNITS "Watts" MAX-ACCESS read-only STATUS current DESCRIPTION "The magnitude of the present input true power." ::= { upsInputEntry 5 } -- -- The Output group. -- upsOutput OBJECT IDENTIFIER ::= { upsObjects 4 } upsOutputSource OBJECT-TYPE SYNTAX INTEGER { other(1), none(2), normal(3), bypass(4), battery(5), booster(6), reducer(7) } MAX-ACCESS read-only STATUS current DESCRIPTION "The present source of output power. The enumeration none(2) indicates that there is no source of output power (and therefore no output power), for example, the system has opened the output breaker." ::= { upsOutput 1 } upsOutputFrequency OBJECT-TYPE SYNTAX NonNegativeIntegerCase [Page 9]RFC 1628 UPS MIB May 1994 UNITS "0.1 Hertz" MAX-ACCESS read-only STATUS current DESCRIPTION "The present output frequency." ::= { upsOutput 2 } upsOutputNumLines OBJECT-TYPE SYNTAX NonNegativeInteger MAX-ACCESS read-only STATUS current DESCRIPTION "The number of output lines utilized in this device. This variable indicates the number of rows in the output table." ::= { upsOutput 3 } upsOutputTable OBJECT-TYPE SYNTAX SEQUENCE OF UpsOutputEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A list of output table entries. The number of entries is given by the value of upsOutputNumLines." ::= { upsOutput 4 } upsOutputEntry OBJECT-TYPE SYNTAX UpsOutputEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry containing information applicable to a particular output line." INDEX { upsOutputLineIndex } ::= { upsOutputTable 1 } UpsOutputEntry ::= SEQUENCE { upsOutputLineIndex PositiveInteger, upsOutputVoltage NonNegativeInteger, upsOutputCurrent NonNegativeInteger, upsOutputPower NonNegativeInteger, upsOutputPercentLoad INTEGER } upsOutputLineIndex OBJECT-TYPE SYNTAX PositiveInteger MAX-ACCESS not-accessible STATUS currentCase [Page 10]RFC 1628 UPS MIB May 1994 DESCRIPTION "The output line identifier." ::= { upsOutputEntry 1 } upsOutputVoltage OBJECT-TYPE SYNTAX NonNegativeInteger UNITS "RMS Volts" MAX-ACCESS read-only STATUS current DESCRIPTION "The present output voltage." ::= { upsOutputEntry 2 } upsOutputCurrent OBJECT-TYPE SYNTAX NonNegativeInteger UNITS "0.1 RMS Amp" MAX-ACCESS read-only STATUS current DESCRIPTION "The present output current." ::= { upsOutputEntry 3 } upsOutputPower OBJECT-TYPE SYNTAX NonNegativeInteger UNITS "Watts" MAX-ACCESS read-only STATUS current DESCRIPTION "The present output true power." ::= { upsOutputEntry 4 } upsOutputPercentLoad OBJECT-TYPE SYNTAX INTEGER (0..200) UNITS "percent" MAX-ACCESS read-only STATUS current DESCRIPTION "The percentage of the UPS power capacity presently being used on this output line, i.e., the greater of the percent load of true power capacity and the percent load of VA." ::= { upsOutputEntry 5 }Case [Page 11]RFC 1628 UPS MIB May 1994 -- -- The Bypass group. -- upsBypass OBJECT IDENTIFIER ::= { upsObjects 5 } upsBypassFrequency OBJECT-TYPE SYNTAX NonNegativeInteger UNITS "0.1 Hertz" MAX-ACCESS read-only STATUS current DESCRIPTION "The present bypass frequency." ::= { upsBypass 1 } upsBypassNumLines OBJECT-TYPE SYNTAX NonNegativeInteger MAX-ACCESS read-only STATUS current DESCRIPTION "The number of bypass lines utilized in this device. This entry indicates the number of rows in the bypass table." ::= { upsBypass 2 } upsBypassTable OBJECT-TYPE SYNTAX SEQUENCE OF UpsBypassEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A list of bypass table entries. The number of entries is given by the value of upsBypassNumLines." ::= { upsBypass 3 } upsBypassEntry OBJECT-TYPE SYNTAX UpsBypassEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry containing information applicable to a particular bypass input." INDEX { upsBypassLineIndex } ::= { upsBypassTable 1 } UpsBypassEntry ::= SEQUENCE { upsBypassLineIndex PositiveInteger, upsBypassVoltage NonNegativeInteger, upsBypassCurrent NonNegativeInteger,Case [Page 12]RFC 1628 UPS MIB May 1994 upsBypassPower NonNegativeInteger } upsBypassLineIndex OBJECT-TYPE SYNTAX PositiveInteger MAX-ACCESS not-accessible STATUS current DESCRIPTION "The bypass line identifier." ::= { upsBypassEntry 1 } upsBypassVoltage OBJECT-TYPE SYNTAX NonNegativeInteger UNITS "RMS Volts" MAX-ACCESS read-only STATUS current DESCRIPTION "The present bypass voltage." ::= { upsBypassEntry 2 } upsBypassCurrent OBJECT-TYPE SYNTAX NonNegativeInteger UNITS "0.1 RMS Amp" MAX-ACCESS read-only STATUS current DESCRIPTION "The present bypass current." ::= { upsBypassEntry 3 } upsBypassPower OBJECT-TYPE SYNTAX NonNegativeInteger UNITS "Watts" MAX-ACCESS read-only STATUS current DESCRIPTION "The present true power conveyed by the bypass." ::= { upsBypassEntry 4 } -- -- The Alarm group. -- upsAlarm OBJECT IDENTIFIER ::= { upsObjects 6 } upsAlarmsPresent OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-onlyCase [Page 13]RFC 1628 UPS MIB May 1994 STATUS current DESCRIPTION "The present number of active alarm conditions." ::= { upsAlarm 1 } upsAlarmTable OBJECT-TYPE SYNTAX SEQUENCE OF UpsAlarmEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A list of alarm table entries. The table contains zero, one, or many rows at any moment, depending upon the number of alarm conditions in effect. The table is initially empty at agent startup. The agent creates a row in the table each time a condition is detected and deletes that row when that condition no longer pertains. The agent creates the first row with upsAlarmId equal to 1, and increments the value of upsAlarmId each time a new row is created, wrapping to the first free value greater than or equal to 1 when the maximum value of upsAlarmId would otherwise be exceeded. Consequently, after multiple operations, the table may become sparse, e.g., containing entries for rows 95, 100, 101, and 203 and the entries should not be assumed to be in chronological order because upsAlarmId might have wrapped. Alarms are named by an AutonomousType (OBJECT IDENTIFIER), upsAlarmDescr, to allow a single table to reflect well known alarms plus alarms defined by a particular implementation, i.e., as documented in the private enterprise MIB definition for the device. No two rows will have the same value of upsAlarmDescr, since alarms define conditions. In order to meet this requirement, care should be taken in the definition of alarm conditions to insure that a system cannot enter the same condition multiple times simultaneously. The number of rows in the table at any given time is reflected by the value of upsAlarmsPresent." ::= { upsAlarm 2 } upsAlarmEntry OBJECT-TYPE SYNTAX UpsAlarmEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry containing information applicable to aCase [Page 14]RFC 1628 UPS MIB May 1994
⌨️ 快捷键说明
复制代码
Ctrl + C
搜索代码
Ctrl + F
全屏模式
F11
切换主题
Ctrl + Shift + D
显示快捷键
?
增大字号
Ctrl + =
减小字号
Ctrl + -