⭐ 欢迎来到虫虫下载站! | 📦 资源下载 📁 资源专辑 ℹ️ 关于我们
⭐ 虫虫下载站

📄 rfc1628.txt

📁 中、英文RFC文档大全打包下载完全版 .
💻 TXT
📖 第 1 页 / 共 5 页
字号:
Network Working Group                                    J. Case, EditorRequest for Comments: 1628                   SNMP Research, IncorporatedCategory: Standards Track                                       May 1994                    UPS Management Information BaseStatus of this Memo   This document specifies an Internet standards track protocol for the   Internet community, and requests discussion and suggestions for   improvements.  Please refer to the current edition of the "Internet   Official Protocol Standards" (STD 1) for the standardization state   and status of this protocol.  Distribution of this memo is unlimited.Table of Contents   1. Introduction ..............................................    1   2. The SNMPv2 Network Management Framework ...................    2   2.1 Object Definitions .......................................    2   3. Overview ..................................................    2   4. Definitions ...............................................    3   4.1 The Device Identification Group...........................    4   4.2 The Battery Group ........................................    5   4.3 The Input Group ..........................................    7   4.4 The Output Group .........................................    9   4.5 The Bypass Group .........................................   12   4.6 The Alarm Group ..........................................   13   4.7 The Test Group ...........................................   19   4.8 The Control Group ........................................   23   4.9 The Configuration Group ..................................   26   5. Acknowledgements ..........................................   43   6. References ................................................   44   7. Security Considerations ...................................   45   8. Author's Address ..........................................   451.  Introduction   This memo defines a portion of the Management Information Base (MIB)   for use with network management protocols in the Internet community.   In particular, it defines objects for managing uninterruptible power   supply (UPS) systems.Case                                                            [Page 1]RFC 1628                        UPS MIB                         May 19942.  The SNMPv2 Network Management Framework   The SNMPv2 Network Management Framework consists of four major   components.  They are:      o    RFC 1442 which defines the SMI, the mechanisms used for           describing and naming objects for the purpose of management.      o    STD 17, RFC 1213 defines MIB-II, the core set of managed           objects for the Internet suite of protocols.      o    RFC 1445 which defines the administrative and other           architectural aspects of the framework.      o    RFC 1448 which defines the protocol used for network access           to managed objects.   The Framework permits new objects to be defined for the purpose of   experimentation and evaluation.2.1.  Object Definitions   Managed objects are accessed via a virtual information store, termed   the Management Information Base or MIB.  Objects in the MIB are   defined using the subset of Abstract Syntax Notation One (ASN.1)   defined in the SMI.  In particular, each object type is named by an   OBJECT IDENTIFIER, an administratively assigned name.  The object   type together with an object instance serves to uniquely identify a   specific instantiation of the object.  For human convenience, we   often use a textual string, termed the descriptor, to refer to the   object type.3.  Overview   This document defines the managed objects for Uninterruptible Power   Supplies which are to be manageable via the Simple Network Management   Protocol (SNMP).Case                                                            [Page 2]RFC 1628                        UPS MIB                         May 19944.  Definitions   UPS-MIB DEFINITIONS ::= BEGIN   IMPORTS       MODULE-IDENTITY, OBJECT-TYPE, NOTIFICATION-TYPE,       OBJECT-IDENTITY, Counter32, Gauge32, Integer32           FROM SNMPv2-SMI       DisplayString, TimeStamp, TimeInterval, TestAndIncr,         AutonomousType           FROM SNMPv2-TC       MODULE-COMPLIANCE, OBJECT-GROUP           FROM SNMPv2-CONF;   upsMIB MODULE-IDENTITY       LAST-UPDATED "9402230000Z"       ORGANIZATION "IETF UPS MIB Working Group"       CONTACT-INFO              "        Jeffrey D. Case                Postal: SNMP Research, Incorporated                        3001 Kimberlin Heights Road                        Knoxville, TN  37920                        US                   Tel: +1 615 573 1434                   Fax: +1 615 573 9197                E-mail: case@snmp.com"       DESCRIPTION               "The MIB module to describe Uninterruptible Power               Supplies."       ::= { mib-2 33 }   PositiveInteger ::= TEXTUAL-CONVENTION       DISPLAY-HINT "d"       STATUS       current       DESCRIPTION               "This data type is a non-zero and non-negative value."       SYNTAX       INTEGER (1..2147483647)   NonNegativeInteger ::= TEXTUAL-CONVENTION       DISPLAY-HINT "d"       STATUS       current       DESCRIPTION               "This data type is a non-negative value."       SYNTAX       INTEGER (0..2147483647)Case                                                            [Page 3]RFC 1628                        UPS MIB                         May 1994   upsObjects            OBJECT IDENTIFIER ::= { upsMIB 1 }   --   -- The Device Identification group.   --      All objects in this group except for upsIdentName and   --      upsIdentAttachedDevices are set at device initialization   --      and remain static.   --   upsIdent              OBJECT IDENTIFIER ::= { upsObjects 1 }   upsIdentManufacturer OBJECT-TYPE       SYNTAX     DisplayString (SIZE (0..31))       MAX-ACCESS read-only       STATUS     current       DESCRIPTION               "The name of the UPS manufacturer."       ::= { upsIdent 1 }   upsIdentModel OBJECT-TYPE       SYNTAX     DisplayString (SIZE (0..63))       MAX-ACCESS read-only       STATUS     current       DESCRIPTION               "The UPS Model designation."       ::= { upsIdent 2 }   upsIdentUPSSoftwareVersion OBJECT-TYPE       SYNTAX     DisplayString (SIZE (0..63))       MAX-ACCESS read-only       STATUS     current       DESCRIPTION               "The UPS firmware/software version(s).  This variable               may or may not have the same value as               upsIdentAgentSoftwareVersion in some implementations."       ::= { upsIdent 3 }   upsIdentAgentSoftwareVersion OBJECT-TYPE       SYNTAX     DisplayString (SIZE (0..63))       MAX-ACCESS read-only       STATUS     current       DESCRIPTION               "The UPS agent software version.  This variable may or               may not have the same value as               upsIdentUPSSoftwareVersion in some implementations."       ::= { upsIdent 4 }Case                                                            [Page 4]RFC 1628                        UPS MIB                         May 1994   upsIdentName OBJECT-TYPE       SYNTAX     DisplayString (SIZE(0..63))       MAX-ACCESS read-write       STATUS     current       DESCRIPTION               "A string identifying the UPS.  This object should be               set by the administrator."       ::= { upsIdent 5 }   upsIdentAttachedDevices OBJECT-TYPE       SYNTAX     DisplayString (SIZE(0..63))       MAX-ACCESS read-write       STATUS     current       DESCRIPTION               "A string identifying the devices attached to the               output(s) of the UPS.  This object should be set by               the administrator."       ::= { upsIdent 6 }   --   -- Battery Group   --   upsBattery            OBJECT IDENTIFIER ::= { upsObjects 2 }   upsBatteryStatus OBJECT-TYPE       SYNTAX     INTEGER {           unknown(1),           batteryNormal(2),           batteryLow(3),           batteryDepleted(4)       }       MAX-ACCESS read-only       STATUS     current       DESCRIPTION               "The indication of the capacity remaining in the UPS               system's batteries.   A value of batteryNormal               indicates that the remaining run-time is greater than               upsConfigLowBattTime.  A value of batteryLow indicates               that the remaining battery run-time is less than or               equal to upsConfigLowBattTime.  A value of               batteryDepleted indicates that the UPS will be unable               to sustain the present load when and if the utility               power is lost (including the possibility that the               utility power is currently absent and the UPS is               unable to sustain the output)."       ::= { upsBattery 1 }Case                                                            [Page 5]RFC 1628                        UPS MIB                         May 1994   upsSecondsOnBattery OBJECT-TYPE       SYNTAX     NonNegativeInteger       UNITS      "seconds"       MAX-ACCESS read-only       STATUS     current       DESCRIPTION               "If the unit is on battery power, the elapsed time               since the UPS last switched to battery power, or the               time since the network management subsystem was last               restarted, whichever is less.  Zero shall be returned               if the unit is not on battery power."       ::= { upsBattery 2 }   upsEstimatedMinutesRemaining OBJECT-TYPE       SYNTAX     PositiveInteger       UNITS      "minutes"       MAX-ACCESS read-only       STATUS     current       DESCRIPTION               "An estimate of the time to battery charge depletion               under the present load conditions if the utility power               is off and remains off, or if it were to be lost and               remain off."       ::= { upsBattery 3 }   upsEstimatedChargeRemaining OBJECT-TYPE       SYNTAX     INTEGER (0..100)       UNITS      "percent"       MAX-ACCESS read-only       STATUS     current       DESCRIPTION               "An estimate of the battery charge remaining expressed               as a percent of full charge."       ::= { upsBattery 4 }   upsBatteryVoltage OBJECT-TYPE       SYNTAX     NonNegativeInteger       UNITS      "0.1 Volt DC"       MAX-ACCESS read-only       STATUS     current       DESCRIPTION               "The magnitude of the present battery voltage."       ::= { upsBattery 5 }   upsBatteryCurrent OBJECT-TYPE       SYNTAX     Integer32       UNITS      "0.1 Amp DC"       MAX-ACCESS read-onlyCase                                                            [Page 6]RFC 1628                        UPS MIB                         May 1994       STATUS     current       DESCRIPTION               "The present battery current."       ::= { upsBattery 6 }   upsBatteryTemperature OBJECT-TYPE       SYNTAX     Integer32       UNITS      "degrees Centigrade"       MAX-ACCESS read-only       STATUS     current       DESCRIPTION               "The ambient temperature at or near the UPS Battery               casing."       ::= { upsBattery 7 }   --   -- Input Group   --   upsInput              OBJECT IDENTIFIER ::= { upsObjects 3 }   upsInputLineBads OBJECT-TYPE       SYNTAX     Counter32       MAX-ACCESS read-only       STATUS     current       DESCRIPTION               "A count of the number of times the input entered an               out-of-tolerance condition as defined by the               manufacturer.  This count is incremented by one each               time the input transitions from zero out-of-tolerance               lines to one or more input lines out-of-tolerance."       ::= { upsInput 1 }   upsInputNumLines OBJECT-TYPE       SYNTAX     NonNegativeInteger       MAX-ACCESS read-only       STATUS     current       DESCRIPTION               "The number of input lines utilized in this device.               This variable indicates the number of rows in the               input table."       ::= { upsInput 2 }   upsInputTable OBJECT-TYPE       SYNTAX     SEQUENCE OF UpsInputEntry       MAX-ACCESS not-accessibleCase                                                            [Page 7]

⌨️ 快捷键说明

复制代码 Ctrl + C
搜索代码 Ctrl + F
全屏模式 F11
切换主题 Ctrl + Shift + D
显示快捷键 ?
增大字号 Ctrl + =
减小字号 Ctrl + -