rfc1407.txt

来自「中、英文RFC文档大全打包下载完全版 .」· 文本 代码 · 共 1,694 行 · 第 1/5 页

TXT
1,694
字号
              SYNTAX  Gauge              ACCESS  read-only              STATUS  mandatory              DESCRIPTION                      "The number of C-bit Coding Violations encountered                      by a DS3 interface in one of the previous 96,                      individual 15 minute, intervals."              ::= { dsx3IntervalEntry 10 }          dsx3IntervalCESs OBJECT-TYPE              SYNTAX  Gauge              ACCESS  read-only              STATUS  mandatory              DESCRIPTION                      "The number of C-bit Errored Seconds encountered                      by a DS3 interface in one of the previous 96,                      individual 15 minute, intervals."              ::= { dsx3IntervalEntry 11 }          dsx3IntervalCSESs OBJECT-TYPE              SYNTAX  Gauge              ACCESS  read-only              STATUS  mandatory              DESCRIPTION                      "The number of C-bit Severely Errored Seconds                      encountered by a DS3 interface in one of the                      previous 96, individual 15 minute, intervals."              ::= { dsx3IntervalEntry 12 }          -- the DS3/E3 Total          -- The DS3/E3 Total Table contains the cumulative sum of the          -- various statistics for the 24 hour period preceding the          -- current interval.          dsx3TotalTable OBJECT-TYPE              SYNTAX  SEQUENCE OF Dsx3TotalEntry              ACCESS  not-accessible              STATUS  mandatory              DESCRIPTION                      "The DS3/E3 Total table.  24 hour interval."Trunk MIB Working Group                                        [Page 25]RFC 1407                       DS3/E3 MIB                   January 1993              ::= { ds3 8 }          dsx3TotalEntry OBJECT-TYPE              SYNTAX  Dsx3TotalEntry              ACCESS  not-accessible              STATUS  mandatory              DESCRIPTION                      "An entry in the DS3/E3 Total table."              INDEX   { dsx3TotalIndex }              ::= { dsx3TotalTable 1 }          Dsx3TotalEntry ::=              SEQUENCE {                  dsx3TotalIndex                      INTEGER,                  dsx3TotalPESs                      Gauge,                  dsx3TotalPSESs                      Gauge,                  dsx3TotalSEFSs                      Gauge,                  dsx3TotalUASs                      Gauge,                  dsx3TotalLCVs                      Gauge,                  dsx3TotalPCVs                      Gauge,                  dsx3TotalLESs                      Gauge,                  dsx3TotalCCVs                      Gauge,                  dsx3TotalCESs                      Gauge,                  dsx3TotalCSESs                      Gauge              }          dsx3TotalIndex OBJECT-TYPE              SYNTAX  INTEGER (1..65535)              ACCESS  read-only              STATUS  mandatory              DESCRIPTION                      "The index value which uniquely identifies the                      DS3/E3 interface to which this entry is                      applicable.  The interface identified by a                      particular value of this index is the same                      interface as identified by the same value an                      dsx3LineIndex object instance."Trunk MIB Working Group                                        [Page 26]RFC 1407                       DS3/E3 MIB                   January 1993              ::= { dsx3TotalEntry 1 }          dsx3TotalPESs OBJECT-TYPE              SYNTAX  Gauge              ACCESS  read-only              STATUS  mandatory              DESCRIPTION                      "The counter associated with the number of P-bit                      Errored Seconds, encountered by a DS3 interface in                      the previous 24 hour interval"              ::= { dsx3TotalEntry 2 }          dsx3TotalPSESs OBJECT-TYPE              SYNTAX  Gauge              ACCESS  read-only              STATUS  mandatory              DESCRIPTION                      "The counter associated with the number of P-bit                      Severely Errored Seconds, encountered by a DS3                      interface in the previous 24 hour interval."              ::= { dsx3TotalEntry 3 }          dsx3TotalSEFSs OBJECT-TYPE              SYNTAX  Gauge              ACCESS  read-only              STATUS  mandatory              DESCRIPTION                      "The counter associated with the number of                      Severely Errored Framing Seconds, encountered by a                      DS3/E3 interface in the previous 24 hour                      interval."              ::= { dsx3TotalEntry 4 }          dsx3TotalUASs OBJECT-TYPE              SYNTAX  Gauge              ACCESS  read-only              STATUS  mandatory              DESCRIPTION                      "The counter associated with the number of                      Unavailable Seconds, encountered by a DS3                      interface in the previous 24 hour interval."              ::= { dsx3TotalEntry 5 }          dsx3TotalLCVs OBJECT-TYPE              SYNTAX  Gauge              ACCESS  read-only              STATUS  mandatory              DESCRIPTIONTrunk MIB Working Group                                        [Page 27]RFC 1407                       DS3/E3 MIB                   January 1993                      "The counter associated with the number of Line                      Coding Violations encountered by a DS3/E3                      interface in the previous 24 hour interval."              ::= { dsx3TotalEntry 6 }          dsx3TotalPCVs OBJECT-TYPE              SYNTAX  Gauge              ACCESS  read-only              STATUS  mandatory              DESCRIPTION                      "The counter associated with the number of P-bit                      Coding Violations, encountered by a DS3 interface                      in the previous 24 hour interval."              ::= { dsx3TotalEntry 7 }          dsx3TotalLESs OBJECT-TYPE              SYNTAX  Gauge              ACCESS  read-only              STATUS  mandatory              DESCRIPTION                   "The number of Line Errored  Seconds  (BPVs  or                   illegal  zero  sequences) encountered by a DS3/E3                   interface in the previous 24 hour interval."              ::= { dsx3TotalEntry 8 }          dsx3TotalCCVs OBJECT-TYPE              SYNTAX  Gauge              ACCESS  read-only              STATUS  mandatory              DESCRIPTION                      "The number of C-bit Coding Violations encountered                      by a DS3 interface in the previous 24 hour                      interval."              ::= { dsx3TotalEntry 9 }          dsx3TotalCESs OBJECT-TYPE              SYNTAX  Gauge              ACCESS  read-only              STATUS  mandatory              DESCRIPTION                      "The number of C-bit Errored Seconds encountered                      by a DS3 interface in the previous 24 hour                      interval."              ::= { dsx3TotalEntry 10 }          dsx3TotalCSESs OBJECT-TYPE              SYNTAX  Gauge              ACCESS  read-onlyTrunk MIB Working Group                                        [Page 28]RFC 1407                       DS3/E3 MIB                   January 1993              STATUS  mandatory              DESCRIPTION                      "The number of C-bit Severely Errored Seconds                      encountered by a DS3 interface in the previous 24                      hour interval."              ::= { dsx3TotalEntry 11 }          -- The DS3 Far End Group          -- Implementation of this group is optional for all systems          -- that attach to a DS3 Interface.          -- However, only C-bit Parity and SYNTRAN DS3 applications          -- have the capability (option) of providing this information.          -- The DS3 Far End Group consists of four tables:          --   DS3 Far End Configuration          --   DS3 Far End Current          --   DS3 Far End Interval          --   DS3 Far End Total          -- The DS3 Far End Configuration Table contains          -- configuration information          -- reported in the C-bits from the remote end.          dsx3FarEndConfigTable OBJECT-TYPE              SYNTAX  SEQUENCE OF Dsx3FarEndConfigEntry              ACCESS  not-accessible              STATUS  mandatory              DESCRIPTION                 "The DS3 Far End Configuration table."              ::= { ds3 9 }          dsx3FarEndConfigEntry OBJECT-TYPE              SYNTAX  Dsx3FarEndConfigEntry              ACCESS  not-accessible              STATUS  mandatory              DESCRIPTION                   "An entry in the DS3 Far End Configuration table."              INDEX   { dsx3FarEndLineIndex }              ::= { dsx3FarEndConfigTable 1 }          Dsx3FarEndConfigEntry ::=              SEQUENCE {                  dsx3FarEndLineIndex                      INTEGER,                  dsx3FarEndEquipCodeTrunk MIB Working Group                                        [Page 29]RFC 1407                       DS3/E3 MIB                   January 1993                      DisplayString,                  dsx3FarEndLocationIDCode                      DisplayString,                  dsx3FarEndFrameIDCode                      DisplayString,                  dsx3FarEndUnitCode                      DisplayString,                  dsx3FarEndFacilityIDCode                      DisplayString               }          dsx3FarEndLineIndex OBJECT-TYPE              SYNTAX  INTEGER (1..65535)              ACCESS  read-only              STATUS  mandatory              DESCRIPTION                   "The index value which uniquely identifies the                   DS3 interface                   to which this entry is applicable.  The                   interface identified by a particular value of                   this index is the same interface as identified                   by the same value an dsx3LineIndex object                   instance."             ::= { dsx3FarEndConfigEntry 1 }          dsx3FarEndEquipCode OBJECT-TYPE              SYNTAX  DisplayString (SIZE (0..10))              ACCESS  read-write              STATUS  mandatory              DESCRIPTION                    "This is the Far End Equipment Identification code                    that describes the specific piece of equipment.                    It is sent within the Path                    Identification Message."              ::= { dsx3FarEndConfigEntry 2 }          dsx3FarEndLocationIDCode OBJECT-TYPE              SYNTAX  DisplayString (SIZE (0..11))              ACCESS  read-write              STATUS  mandatory              DESCRIPTION                    "This is the Far End Location Identification code                    that describes the specific location of the                    equipment.                    It is sent within the Path                    Identification Message."              ::= { dsx3FarEndConfigEntry 3 }Trunk MIB Working Group                                        [Page 30]RFC 1407                       DS3/E3 MIB                   January 1993          dsx3FarEndFrameIDCode OBJECT-TYPE              SYNTAX  DisplayString (SIZE (0..10))              ACCESS  read-write              STATUS  mandatory              DESCRIPTION                    "This is the Far End Frame Identification code                    that identifies where the equipment is located                    within a building at a given 

⌨️ 快捷键说明

复制代码Ctrl + C
搜索代码Ctrl + F
全屏模式F11
增大字号Ctrl + =
减小字号Ctrl + -
显示快捷键?