📄 rfc2515.txt
字号:
DESCRIPTION "The VCI value of the VCC supporting the ILMI at this ATM interface. If the values of atmInterfaceIlmiVpi and atmInterfaceIlmiVci are both equal to zero then the ILMI is not supported at this ATM interface." DEFVAL { 16 } ::= { atmInterfaceConfEntry 8} atmInterfaceAddressType OBJECT-TYPE SYNTAX INTEGER { private(1), nsapE164(2), nativeE164(3), other(4) } MAX-ACCESS read-only STATUS deprecated DESCRIPTION "The type of primary ATM address configured for use at this ATM interface." ::= { atmInterfaceConfEntry 9 } -- The atmInterfaceAdminAddress object has been replaced by -- atmInterfaceSubscrAddress. atmInterfaceAdminAddress OBJECT-TYPE SYNTAX AtmAddr MAX-ACCESS read-only STATUS deprecated DESCRIPTION "The primary address assigned for administrative purposes, for example, an address associated with the service provider side of a public network UNI (thus, the value of this address corresponds with the value of ifPhysAddress at the host side). If this interface has no assigned administrative address, or when the address used for administrative purposes is the same as that used for ifPhysAddress, then this is an octet string of zero length." ::= { atmInterfaceConfEntry 10 } atmInterfaceMyNeighborIpAddress OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-writeTesink Standards Track [Page 25]RFC 2515 ATM Management Objects February 1999 STATUS current DESCRIPTION "The IP address of the neighbor system connected to the far end of this interface, to which a Network Management Station can send SNMP messages, as IP datagrams sent to UDP port 161, in order to access network management information concerning the operation of that system. Note that the value of this object may be obtained in different ways, e.g., by manual configuration, or through ILMI interaction with the neighbor system." ::= { atmInterfaceConfEntry 11 } atmInterfaceMyNeighborIfName OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "The textual name of the interface on the neighbor system on the far end of this interface, and to which this interface connects. If the neighbor system is manageable through SNMP and supports the object ifName, the value of this object must be identical with that of ifName for the ifEntry of the lowest level physical interface for this port. If this interface does not have a textual name, the value of this object is a zero length string. Note that the value of this object may be obtained in different ways, e.g., by manual configuration, or through ILMI interaction with the neighbor system." ::= { atmInterfaceConfEntry 12 } atmInterfaceCurrentMaxVpiBits OBJECT-TYPE SYNTAX INTEGER (0..12) MAX-ACCESS read-only STATUS current DESCRIPTION "The maximum number of VPI Bits that may currently be used at this ATM interface. The value is the minimum of atmInterfaceMaxActiveVpiBits, and the atmInterfaceMaxActiveVpiBits of the interface's UNI/NNI peer. If the interface does not negotiate with its peer to determine the number of VPI Bits that can be used on the interface, then theTesink Standards Track [Page 26]RFC 2515 ATM Management Objects February 1999 value of this object must equal atmInterfaceMaxActiveVpiBits." ::= { atmInterfaceConfEntry 13 } atmInterfaceCurrentMaxVciBits OBJECT-TYPE SYNTAX INTEGER (0..16) MAX-ACCESS read-only STATUS current DESCRIPTION "The maximum number of VCI Bits that may currently be used at this ATM interface. The value is the minimum of atmInterfaceMaxActiveVciBits, and the atmInterfaceMaxActiveVciBits of the interface's UNI/NNI peer. If the interface does not negotiate with its peer to determine the number of VCI Bits that can be used on the interface, then the value of this object must equal atmInterfaceMaxActiveVciBits." ::= { atmInterfaceConfEntry 14 } atmInterfaceSubscrAddress OBJECT-TYPE SYNTAX AtmAddr MAX-ACCESS read-write STATUS current DESCRIPTION "The identifier assigned by a service provider to the network side of a public network UNI. If this interface has no assigned service provider address, or for other interfaces this is an octet string of zero length." ::= { atmInterfaceConfEntry 15 } -- The ATM Interface DS3 PLCP Table -- This table contains the DS3 PLCP configuration and -- state parameters of those ATM interfaces -- which use DS3 PLCP for carrying ATM cells over DS3. atmInterfaceDs3PlcpTable OBJECT-TYPE SYNTAX SEQUENCE OF AtmInterfaceDs3PlcpEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table contains ATM interface DS3 PLCP parameters and state variables, one entry perTesink Standards Track [Page 27]RFC 2515 ATM Management Objects February 1999 ATM interface port." ::= { atmMIBObjects 3} atmInterfaceDs3PlcpEntry OBJECT-TYPE SYNTAX AtmInterfaceDs3PlcpEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This list contains DS3 PLCP parameters and state variables at the ATM interface and is indexed by the ifIndex value of the ATM interface." INDEX { ifIndex } ::= { atmInterfaceDs3PlcpTable 1} AtmInterfaceDs3PlcpEntry ::= SEQUENCE { atmInterfaceDs3PlcpSEFSs Counter32, atmInterfaceDs3PlcpAlarmState INTEGER, atmInterfaceDs3PlcpUASs Counter32 } atmInterfaceDs3PlcpSEFSs OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of DS3 PLCP Severely Errored Framing Seconds (SEFS). Each SEFS represents a one-second interval which contains one or more SEF events." ::= { atmInterfaceDs3PlcpEntry 1} atmInterfaceDs3PlcpAlarmState OBJECT-TYPE SYNTAX INTEGER { noAlarm(1), receivedFarEndAlarm(2), incomingLOF(3) } MAX-ACCESS read-only STATUS current DESCRIPTION "This variable indicates if there is an alarm present for the DS3 PLCP. The value receivedFarEndAlarm means that the DS3 PLCP has received an incoming Yellow Signal, the value incomingLOF means that the DS3 PLCP has declared a loss of frame (LOF) failure condition, and the value noAlarmTesink Standards Track [Page 28]RFC 2515 ATM Management Objects February 1999 means that there are no alarms present. Transition from the failure to the no alarm state occurs when no defects (e.g., LOF) are received for more than 10 seconds." ::= { atmInterfaceDs3PlcpEntry 2} atmInterfaceDs3PlcpUASs OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of Unavailable Seconds encountered by the PLCP." ::= { atmInterfaceDs3PlcpEntry 3} -- The ATM Interface TC Sublayer Table -- This table contains TC sublayer configuration and -- state parameters of those ATM interfaces -- which use TC sublayer for carrying ATM cells over -- SONET/SDH or DS3. atmInterfaceTCTable OBJECT-TYPE SYNTAX SEQUENCE OF AtmInterfaceTCEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table contains ATM interface TC Sublayer parameters and state variables, one entry per ATM interface port." ::= { atmMIBObjects 4} atmInterfaceTCEntry OBJECT-TYPE SYNTAX AtmInterfaceTCEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This list contains TC Sublayer parameters and state variables at the ATM interface and is indexed by the ifIndex value of the ATM interface." INDEX {ifIndex } ::= { atmInterfaceTCTable 1} AtmInterfaceTCEntry ::= SEQUENCE { atmInterfaceOCDEvents Counter32, atmInterfaceTCAlarmState INTEGERTesink Standards Track [Page 29]RFC 2515 ATM Management Objects February 1999 } atmInterfaceOCDEvents OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of times the Out of Cell Delineation (OCD) events occur. If seven consecutive ATM cells have Header Error Control (HEC) violations, an OCD event occurs. A high number of OCD events may indicate a problem with the TC Sublayer." ::= { atmInterfaceTCEntry 1} atmInterfaceTCAlarmState OBJECT-TYPE SYNTAX INTEGER { noAlarm(1), lcdFailure(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "This variable indicates if there is an alarm present for the TC Sublayer. The value lcdFailure(2) indicates that the TC Sublayer is currently in the Loss of Cell Delineation (LCD) defect maintenance state. The value noAlarm(1) indicates that the TC Sublayer is currently not in the LCD defect maintenance state." ::= { atmInterfaceTCEntry 2} -- ATM Traffic Descriptor Parameter Table -- This table contains a set of self-consistent -- ATM traffic parameters including the -- ATM traffic service category. -- The ATM virtual link tables (i.e., VPL and VCL tables) -- will use this ATM Traffic Descriptor table -- to assign traffic parameters and service category -- to the receive and transmit directions of -- the ATM virtual links (i.e., VPLs and VCLs). -- The ATM VPL or VCL table will indicate a row -- in the atmTrafficDescrParamTable -- using its atmTrafficDescrParamIndex value.Tesink Standards Track [Page 30]RFC 2515 ATM Management Objects February 1999 -- The management application can then compare a set of -- ATM traffic parameters with a single value. -- If no suitable ro
⌨️ 快捷键说明
复制代码
Ctrl + C
搜索代码
Ctrl + F
全屏模式
F11
切换主题
Ctrl + Shift + D
显示快捷键
?
增大字号
Ctrl + =
减小字号
Ctrl + -