⭐ 欢迎来到虫虫下载站! | 📦 资源下载 📁 资源专辑 ℹ️ 关于我们
⭐ 虫虫下载站

📄 rfc2515.txt

📁 中、英文RFC文档大全打包下载完全版 .
💻 TXT
📖 第 1 页 / 共 5 页
字号:
          DESCRIPTION           "The VCI value of the VCC supporting            the ILMI at this ATM interface.  If the values of            atmInterfaceIlmiVpi and atmInterfaceIlmiVci are            both equal to zero then the ILMI is not            supported at this ATM interface."          DEFVAL { 16 }          ::= { atmInterfaceConfEntry 8}     atmInterfaceAddressType  OBJECT-TYPE          SYNTAX         INTEGER {                            private(1),                            nsapE164(2),                            nativeE164(3),                            other(4)                              }          MAX-ACCESS     read-only          STATUS         deprecated          DESCRIPTION           "The type of primary ATM address configured            for use at this ATM interface."          ::= { atmInterfaceConfEntry 9 }     --  The atmInterfaceAdminAddress object has been replaced by     --  atmInterfaceSubscrAddress.     atmInterfaceAdminAddress OBJECT-TYPE          SYNTAX         AtmAddr          MAX-ACCESS     read-only          STATUS         deprecated          DESCRIPTION           "The primary address assigned for administrative purposes,            for example, an address associated with the            service provider side of a public network UNI            (thus, the value of this address corresponds            with the value of ifPhysAddress at the host side).            If this interface has no assigned administrative            address, or when the address used for            administrative purposes is the same as that used            for ifPhysAddress, then this is an octet string of            zero length."          ::= { atmInterfaceConfEntry 10 }     atmInterfaceMyNeighborIpAddress OBJECT-TYPE          SYNTAX         IpAddress          MAX-ACCESS     read-writeTesink                      Standards Track                    [Page 25]RFC 2515                 ATM Management Objects            February 1999          STATUS         current          DESCRIPTION           "The IP address of the neighbor system connected to            the  far end of this interface, to which a Network            Management Station can send SNMP messages, as IP            datagrams sent to UDP port 161, in order to access            network management information concerning the            operation of that system.  Note that the value            of this object may be obtained in different ways,            e.g., by manual configuration, or through ILMI            interaction with the neighbor system."          ::= { atmInterfaceConfEntry 11 }     atmInterfaceMyNeighborIfName OBJECT-TYPE          SYNTAX         DisplayString          MAX-ACCESS     read-write          STATUS         current          DESCRIPTION           "The textual name of the interface on the neighbor            system on the far end of this interface, and to            which this interface connects.  If the neighbor            system is manageable through SNMP and supports            the object ifName, the value of this object must            be identical with that of ifName for the ifEntry            of the lowest level physical interface            for this port.  If this interface does not have a            textual name, the value of this object is a zero            length string.  Note that the value of this object            may be obtained in different ways, e.g., by manual            configuration, or through ILMI interaction with            the neighbor system."          ::= { atmInterfaceConfEntry 12 }     atmInterfaceCurrentMaxVpiBits    OBJECT-TYPE          SYNTAX         INTEGER  (0..12)          MAX-ACCESS     read-only          STATUS         current          DESCRIPTION           "The maximum number of VPI Bits that may            currently be used at this ATM interface.            The value is the minimum of            atmInterfaceMaxActiveVpiBits, and the            atmInterfaceMaxActiveVpiBits of the interface's            UNI/NNI peer.            If the interface does not negotiate with            its peer to determine the number of VPI Bits            that can be used on the interface, then theTesink                      Standards Track                    [Page 26]RFC 2515                 ATM Management Objects            February 1999            value of this object must equal            atmInterfaceMaxActiveVpiBits."          ::= { atmInterfaceConfEntry 13 }     atmInterfaceCurrentMaxVciBits    OBJECT-TYPE          SYNTAX         INTEGER  (0..16)          MAX-ACCESS     read-only          STATUS         current          DESCRIPTION           "The maximum number of VCI Bits that may            currently be used at this ATM interface.            The value is the minimum of            atmInterfaceMaxActiveVciBits, and the            atmInterfaceMaxActiveVciBits of the interface's            UNI/NNI peer.            If the interface does not negotiate with            its peer to determine the number of VCI Bits            that can be used on the interface, then the            value of this object must equal            atmInterfaceMaxActiveVciBits."          ::= { atmInterfaceConfEntry 14 }     atmInterfaceSubscrAddress OBJECT-TYPE          SYNTAX         AtmAddr          MAX-ACCESS     read-write          STATUS         current          DESCRIPTION           "The identifier assigned by a service provider            to the network side of a public network UNI.            If this interface has no assigned service provider            address, or for other interfaces this is an octet string            of zero length."          ::= { atmInterfaceConfEntry 15 }     -- The ATM Interface DS3 PLCP Table     -- This table contains the DS3 PLCP configuration and     -- state parameters of those ATM interfaces     -- which use DS3 PLCP for carrying ATM cells over DS3.     atmInterfaceDs3PlcpTable  OBJECT-TYPE          SYNTAX       SEQUENCE OF AtmInterfaceDs3PlcpEntry          MAX-ACCESS   not-accessible          STATUS       current          DESCRIPTION           "This table contains ATM interface DS3 PLCP            parameters and state variables, one entry perTesink                      Standards Track                    [Page 27]RFC 2515                 ATM Management Objects            February 1999            ATM interface port."          ::= { atmMIBObjects 3}     atmInterfaceDs3PlcpEntry OBJECT-TYPE          SYNTAX         AtmInterfaceDs3PlcpEntry          MAX-ACCESS     not-accessible          STATUS         current          DESCRIPTION           "This list contains DS3 PLCP parameters and            state variables at the ATM interface and is            indexed by the ifIndex value of the ATM interface."          INDEX    { ifIndex }          ::= { atmInterfaceDs3PlcpTable 1}     AtmInterfaceDs3PlcpEntry    ::= SEQUENCE  {          atmInterfaceDs3PlcpSEFSs       Counter32,          atmInterfaceDs3PlcpAlarmState  INTEGER,          atmInterfaceDs3PlcpUASs        Counter32            }     atmInterfaceDs3PlcpSEFSs  OBJECT-TYPE          SYNTAX         Counter32          MAX-ACCESS     read-only          STATUS         current          DESCRIPTION           "The number of DS3 PLCP Severely Errored Framing            Seconds (SEFS). Each SEFS represents a            one-second interval which contains            one or more SEF events."          ::= { atmInterfaceDs3PlcpEntry 1}     atmInterfaceDs3PlcpAlarmState    OBJECT-TYPE          SYNTAX         INTEGER {                            noAlarm(1),                            receivedFarEndAlarm(2),                            incomingLOF(3)                                 }          MAX-ACCESS     read-only          STATUS         current          DESCRIPTION           "This variable indicates if there is an            alarm present for the DS3 PLCP.  The value            receivedFarEndAlarm means that the DS3 PLCP            has received an incoming Yellow            Signal, the value incomingLOF means that            the DS3 PLCP has declared a loss of frame (LOF)            failure condition, and the value noAlarmTesink                      Standards Track                    [Page 28]RFC 2515                 ATM Management Objects            February 1999            means that there are no alarms present.            Transition from the failure to the no alarm state            occurs when no defects (e.g., LOF) are received            for more than 10 seconds."          ::= { atmInterfaceDs3PlcpEntry 2}     atmInterfaceDs3PlcpUASs  OBJECT-TYPE          SYNTAX         Counter32          MAX-ACCESS     read-only          STATUS         current          DESCRIPTION           "The counter associated with the number of            Unavailable Seconds encountered by the PLCP."          ::= { atmInterfaceDs3PlcpEntry 3}     -- The ATM Interface TC Sublayer Table     -- This table contains TC sublayer configuration and     -- state parameters of those ATM interfaces     -- which use TC sublayer for carrying ATM cells over     -- SONET/SDH or DS3.     atmInterfaceTCTable  OBJECT-TYPE          SYNTAX         SEQUENCE OF AtmInterfaceTCEntry          MAX-ACCESS     not-accessible          STATUS         current          DESCRIPTION           "This table contains ATM interface TC            Sublayer parameters and state variables,            one entry per ATM interface port."          ::= { atmMIBObjects 4}     atmInterfaceTCEntry OBJECT-TYPE          SYNTAX         AtmInterfaceTCEntry          MAX-ACCESS     not-accessible          STATUS         current          DESCRIPTION           "This list contains TC Sublayer parameters            and state variables at the ATM interface and is            indexed by the ifIndex value of the ATM interface."          INDEX  {ifIndex }          ::= { atmInterfaceTCTable 1}     AtmInterfaceTCEntry    ::= SEQUENCE  {          atmInterfaceOCDEvents      Counter32,          atmInterfaceTCAlarmState   INTEGERTesink                      Standards Track                    [Page 29]RFC 2515                 ATM Management Objects            February 1999            }     atmInterfaceOCDEvents  OBJECT-TYPE          SYNTAX         Counter32          MAX-ACCESS     read-only          STATUS         current          DESCRIPTION           "The number of times the Out of Cell            Delineation (OCD) events occur.  If seven            consecutive ATM cells have Header Error            Control (HEC) violations, an OCD event occurs.            A high number of OCD events may indicate a            problem with the TC Sublayer."          ::= { atmInterfaceTCEntry 1}     atmInterfaceTCAlarmState    OBJECT-TYPE          SYNTAX         INTEGER {                            noAlarm(1),                            lcdFailure(2)                                  }          MAX-ACCESS     read-only          STATUS         current          DESCRIPTION           "This variable indicates if there is an            alarm present for the TC Sublayer.  The value            lcdFailure(2) indicates that the TC Sublayer            is currently in the Loss of Cell Delineation            (LCD) defect maintenance state.  The value            noAlarm(1) indicates that the TC Sublayer            is currently not in the LCD defect            maintenance state."           ::= { atmInterfaceTCEntry 2}     --  ATM Traffic Descriptor Parameter Table     -- This table contains a set of self-consistent     -- ATM traffic parameters including the     -- ATM traffic service category.     -- The ATM virtual link tables (i.e., VPL and VCL tables)     -- will use this ATM Traffic Descriptor table     -- to assign traffic parameters and service category     -- to the receive and transmit directions of     -- the ATM virtual links (i.e., VPLs and VCLs).     -- The ATM VPL or VCL table will indicate a row     -- in the atmTrafficDescrParamTable     -- using its atmTrafficDescrParamIndex value.Tesink                      Standards Track                    [Page 30]RFC 2515                 ATM Management Objects            February 1999     -- The management application can then compare a set of     -- ATM traffic parameters with a single value.     -- If no suitable ro

⌨️ 快捷键说明

复制代码 Ctrl + C
搜索代码 Ctrl + F
全屏模式 F11
切换主题 Ctrl + Shift + D
显示快捷键 ?
增大字号 Ctrl + =
减小字号 Ctrl + -