📄 rfc398.txt
字号:
NWG/RFC #398 John R. PickensUCSB Online Graphics Edward D. FaehNIC 11911 UCSB 22 Sept 72At present, users with TEKTRONIX or IMLAC terminals or with systemsthat support the proposed level 0 graphics protocol can access UCSBgraphics. Listed below are the ICP sockets for the currentlysupported terminals and protocols. Any detailed questions about orproblems with a particular protocol should be directed to Ed Faeh(805-961-4047). Socket Supports x'701' IMLAC with special software designed by Jerry Powell (MITRE Corp.). Graphics is sent over a simplex connection to the IMLAC. Alphanumerics are sent over a TELNET-like connection to a separate device. The IMLAC software can be loaded from MIT-DMCG. x'703' IMLAC with 80x80 display grid and Standard Text and Edit Package. Some IMLACs have a 64x64 display grid. Therefore, the choice may be made in the near future to format the graphics output from this connection for the smaller grid resolution so that both terminal types may be handled. Display resolution is limited with this terminal configuration as normal UCSB terminals have 1024x1024 grid. Nevertheless, meaningful displays are obtained even at the lower resolutions. x'705' Current Level 0 graphics protocol. x'707' Same as x'701' but with special UCSB online keyboard as input. This configuration averts the necessity of spelling out online operators. x'709' Same as x'705' but with special UCSB online keyboard as input. [Page 1]NWG/RFC# 398 JRP EDF 22-SEP-72 16:25 11911UCSB OnLine Graphics x'801' TEKTRONIX terminals. Models 4002-A 4010, and T-4002 have been tested successfully. Presumably all other 4002 compatible terminals will also work.The primary problems that will be encountered by the network usercenter about display formatting. For historical reasons (i.e. onlyone type of terminal in house ) no means were included in the systemto facilitate terminal independent random positioning of alphanumericoutput. Thus, a program which draws and labels a graph neatly on oneterminal might label like a kindergartener on other terminals.Nevertheless, this problem can be minimized with careful programmingand efforts are underway to provide at least minimal alphanumericdevice independence.Users interested in experimenting with online graphics should contactJohn Pickens (805-961-3454), Glen Davis (805-961-2462), or MarkKrilonovich (805-961-3454). Suggestions and criticisms of all aspectsof the UCSB OnLine - Network User interface are desired. [ This RFC was put into machine readable form for entry ] [ into the online RFC archives by BBN Corp. under the ] [ direction of Alex McKenzie. 1/97 ] [Page 2]
⌨️ 快捷键说明
复制代码
Ctrl + C
搜索代码
Ctrl + F
全屏模式
F11
切换主题
Ctrl + Shift + D
显示快捷键
?
增大字号
Ctrl + =
减小字号
Ctrl + -